APPENDIX B: B.1 PRP AND HSR ETHERNET PROTOCOLS GEK-113000-AFF650 DIGITAL BAY CONTROLLER b-5 PRP can be enabled in configuration through a setting available on the network configuration menu (Product Setup? Communication Settings? Network (Ethernet), REDUNDANCY, which already has the capability of enabling Failover redundancy. When REDUNDANCY is set to PRP, the ports dedicated for PRP operate in redundant mode. The rights associated with configuring PRP follow the security requirements for network...
Page 242
B-6F650 DIGITAL BAY CONTROLLER GEK-113000-AF B.2 RSTP (IEEE 802.1D-2004) AND DAISY CHAIN APPENDIX B: B.2 RSTP (IEEE 802.1D-2004) and daisy chain B.2.1 RSTP description The Rapid Spanning Tree Protocol (RTSP), like STP, was designed to avoid loops in an Ethernet network. Rapid Spanning Tree Protocol (RSTP) (IEEE 802.1w) is an evolution of the Span ning Tree Protocol (STP) (802.1d standard) and provides for faster spanning tree convergence after a topology change. B.2.2 RSTP concepts The IEEE 802.1d...
Page 243
APPENDIX B: B.2 RSTP (IEEE 802.1D-2004) AND DAISY CHAIN GEK-113000-AFF650 DIGITAL BAY CONTROLLER b-7 B.2.3 Use in meshed networks One great strength of RSTP is its support for all kinds of meshed topologies. The resulting flexibility regarding the installation is a clear advantage over th e stringent restrictions that are imposed by ring protocols such as MRP and ring installations. However, this flexibility harbors one great disadvantage, namely the reconfiguration time, which for an interconnected...
Page 244
B-8F650 DIGITAL BAY CONTROLLER GEK-113000-AF B.3 LINK LOSS ALERT (LLA) APPENDIX B: B.3 Link loss alert (LLA) B.3.1 LLA (Link Loss Alert) operation: The operation of ports A and B are as follows: Ports A and B use port A’s MAC and IP address settings while port B is in standby mode in that it does not actively communicate on the Ethernet network but monitors its link. B.3.2 LLA priority If this setting is set to enabled, the port A has the priority. If PORTA’s LLA detects a problem with the link,...
Page 245
GEK-113000-AFF650 DIGITAL BAY CONTROLLER C-1 F650 Digital Bay Controller Appendix C: GE Grid Solutions FACTORY DEFAULT LOGIC
Page 249
APPENDIX C: GEK-113000-AFF650 DIGITAL BAY CONTROLLER c-5 OR3 25 OR3 26 FREQUENCY PICK UPS VO_054_81O_PKP 45 inOR 1 VO_055_81U_PKP inOR 2 46 inOR 3 VO_054_81O_PKP out OR1 47 VO_055_81U_PK P 48 inOR 1 VO_056_ALL_FREQUENCY_PKP 49 inOR 2 inOR 3 out OR1 O VERFREQ 1 PK P 111 OVERFREQ2 PKP 112 O VERFREQ 3 PK P 113 UNDERF REQ 1 PKP 114 UNDERFREQ2 PK P 115 UNDERFREQ3 PK P 116 BRO KE N CONDUCTOROR3 273 BROKEN CONDUCT1 PK P 274 BROKEN CONDUCT2 PK P 275 BROKEN CONDUCT3 PK P 276 VO_018_BRO KE N_CONDUCTOR_PK P...