Page 231
APPENDIX A: A.1 OPERANDS - F650 - MODEL FX - GX GEK-113000-AFF650 DIGITAL BAY CONTROLLER A-27 AutorecloserAR LEVEL BLOCK Recloser element block by level AR PULSE BLOCK Recloser element block by pulse AR PULSE UNBLOCK Recloser element unblock by pulse AR INITIATE Reclose initiate AR CONDS INPUT Reclose permission condition in input to Function 1 = ther e are conditions AR CLOSE BREAKER Closing permission for the recloser AR OUT OF SERVICE Recloser out of service AR READY Recloser READY AR LOCKOUT...
Page 232
A-28F650 DIGITAL BAY CONTROLLER GEK-113000-AF A.1 OPERANDS - F650 - MODEL FX - GX APPENDIX A: Directional PowerDIR PWR1 BLOCK Directional power element block Group 1 DIR PWR1 STG1 PKP Directional Power element pickup level 1 Group 1 DIR PWR1 STG1 OP Directional Power element operation level 1 Group 1 DIR PWR1 STG2 PKP Directional Power element pickup level 2 Group 1 DIR PWR1 STG2 OP Directional Power element operation level 2 Group 1 DIR PWR1 STG PKP Directional power element pickup Group 1 DIR PWR1...
Page 233
APPENDIX A: A.1 OPERANDS - F650 - MODEL FX - GX GEK-113000-AFF650 DIGITAL BAY CONTROLLER A-29 Load EncroachmentLOAD ENCR1 BLK Load Encroachment element block Group 1 LOAD ENCR1 PKP Load Encroachment element pickup Group 1 LOAD ENCR1 OP Load Encroachment element operation Group 1 LOAD ENCR2 BLK Load Encroachment element block Group 2 LOAD ENCR2 PKP Load Encroachment element pickup Group 2 LOAD ENCR2 OP Load Encroachment element operation Group 2 LOAD ENCR3 BLK Load Encroachment element block Group 3 LOAD...
Page 234
A-30F650 DIGITAL BAY CONTROLLER GEK-113000-AF A.1 OPERANDS - F650 - MODEL FX - GX APPENDIX A: wattmetric Ground Fault Low (Logic Operands)32N1 LOW BLOCK wattmetric Ground Fault Element Block Low Level Gr oup 1 32N1 LOW PKP wattmetric Ground Fault Element Global Pickup (cur rent , voltage and power) Low Level Group 1 32N1 LOW OC PKP wattmetric Ground Fault Element Overcurrent Pickup Low Level Gr oup 1 32N1 LOW OP wattmetric Ground Fault Element Operation Low Level Gr oup 1 32N2 LOW BLOCK...
Page 235
APPENDIX A: A.1 OPERANDS - F650 - MODEL FX - GX GEK-113000-AFF650 DIGITAL BAY CONTROLLER A-31 Remote InputsRemote Input 1 Flag is set , logic =1 Remote Input 2 Flag is set , logic =1 ... ... Remote Input 32 Flag is set , logic =1 Remote Devices Remote Device 1 Flag is set , logic =1 Remote Device 2 Flag is set , logic =1 ... ... Remote Device 16 Flag is set , logic =1 GOOSE DIG INPUTS Rem GOOSE Dig Input 1 Flag is set , logic = 1 Rem GOOSE Dig Input 2 Flag is set , logic =1 ... ... Rem GOOSE Dig...
Page 236
A-32F650 DIGITAL BAY CONTROLLER GEK-113000-AF A.1 OPERANDS - F650 - MODEL FX - GX APPENDIX A:
Page 237
GEK-113000-AFF650 DIGITAL BAY CONTROLLER b-1 F650 Digital Bay Controller Appendix B: GE Grid Solutions REDUNDANCY PROTOCOL B.1 PRP and HSR Ethernet protocols Industrial real-time Ethernets typically demand much higher availability and uninterrupted operation than office Ethernet solutions can provide. Even a short loss of connectivity can result in loss of functionality, as for example in some automation, vehicular, power generation, and power distribution systems. To recover from a network failure,...
Page 238
B-2F650 DIGITAL BAY CONTROLLER GEK-113000-AF B.1 PRP AND HSR ETHERNET PROTOCOLS APPENDIX B: Figure B-1: Example of PRP with two LANs (LAN A and LAN B) The two LANs, named LAN_A and LAN_B, are identical in protocol at the MAC level, but they can differ in performance and topology. Transmission delays can also be different. The LANs have no direct connection among them and they are assumed to be fail independent. In some applications, only availability-critical nodes need a double attachment, while...
Page 239
APPENDIX B: B.1 PRP AND HSR ETHERNET PROTOCOLS GEK-113000-AFF650 DIGITAL BAY CONTROLLER b-3 Figure B-2: Example of HSR with HSR ring Definitions: • PRP – Parallel Redundancy Protocol - redundancy protocol for high availability in substation automation networks based on IEC 62439-3 Clause 4 and applicable to netw orks based on Ethernet technology (ISO/IEC 8802-3). • OSI - Open Systems Interconnection - model def ined by the International Organization for Standardization (ISO) for st andardizing the...
Page 240
B-4F650 DIGITAL BAY CONTROLLER GEK-113000-AF B.1 PRP AND HSR ETHERNET PROTOCOLS APPENDIX B: B.1.1 PRP PRP defines a redundancy protocol for high availability in substation automation networks. It is applicable to networks based on Ethernet technology (ISO/IEC 8802-3). PRP is designed to provide seamless recovery in case of a single failure in the network, by using a combination of LAN duplication and frame duplication technique. Identical frames are sent on two completely independent networks that...