2004/11 – Subject to change – Info 20141 Fieldbus Direct, CPV-IB Technical data – Fieldbus node CPV-IB Connection and display components 1 2 4 5 3 6 789 1Red LED: Dia (diagnosis) 2Green LED: Pow (power supply indicator) 3Green LED: RC (remotebus check) 4Green LED: UL (voltage supply to Interbus) 5Green LED: BA (bus active) 6Yellow LED: RD (remotebus disable) 7Switching status displays of CPV solenoid coils 8CP extension connection 9Interbus connection Pin allocation for Interbus interface, incoming (plug view) PinSignalDesignation 1DO1Data out 2/DI1Data in 3GNDReference conductor/earth 4n.c.Not connected 5n.c.Not connected 6/DO1Data out inverse 7/DI1Data in inverse 8n.c.Not connected 9n.c.Not connected HousingScreenConnection to functional earth via R-C combination Pin allocation for Interbus interface, outgoing (socket view) PinSignalDesignation 1DO2Data out 2/DI2Data in 3GNDReference conductor/earth 4n.c.Not connected 5+5 VStation detection1) 6/DO2Data out inverse 7/DI2Data in inverse 8n.c.Not connected 9RBSTStation detection1) HousingScreenConnection to functional earth via R-C combination 1) The incoming interface is electrically isolated from the CPX peripherals. The plug housing is connected to the FE of the CPX terminal via an R-C combination. The CPX terminal contains the protocol chip SUPI3 OPC. This ensures automatic detection ofadditional connected Interbus stations. There is therefore no need for a bridge between pin 5 and pin 9.
Info 201 – Subject to change – 2004/1142 Fieldbus Direct, CPV-IB Accessories – Fieldbus node CPV-IB Ordering data DesignationTy p ePart No. Power supply Power supply socket, straightFBSD-GD-718 497 FBSD-GD-918 495 Power supply socket, angledFBSD-WD-718 524 FBSD-WD-918 525 Bus connection Fieldbus plug, Sub-D connection for Interbus incomingFBS-SUB-9-BU-IB-B532 218 Fieldbus plug, Sub-D connection for Interbus outgoingFBS-SUB-9-GS-IB-B532 217 Mounting screw for standard Sub- D (IP20)UNC 4-40/M3x5340 960 Valve terminal connection Connecting cable WS-WD0.5 mKVI-CP-1-WS-WD-0,5178 564g 1mKVI-CP-1-WS-WD-1.0191 892 2mKVI-CP-1-WS-WD-2163 139 3mKVI-CP-1-WS-WD-3.0191 893 5mKVI-CP-1-WS-WD-5163 138 Connecting cable GS-WD5mKVI-CP-1-GS-WD-5163 137 8mKVI-CP-1-GS-WD-8163 136 Connecting cable GS-GD2 m, for chain link trunkingKVI-CP-2-GS-GD-2170 234g 5 m, for chain link trunkingKVI-CP-2-GS-GD-5170 235 8 m, for chain link trunkingKVI-CP-2-GS-GD-8165 616 User documentation UserdocumentationforCPVDirect,CPVfieldbusnodeGermanP.BE-CP-IB-DE527 515, IBEnglishP.BE-CP-IB-EN527 516 SpanishP.BE-CP-IB-ES527 517 FrenchP.BE-CP-IB-FR527 518 ItalianP.BE-CP-IB-IT527 519 SwedishP.BE-CP-IB-SV527 520 Software CD-ROMValve terminal user documentation (PDF)P.CD-VALVE-T183 350 UtilitiesP.CD-VI-UTILITIES-2533 500
2004/11 – Subject to change – Info 20143 Fieldbus Direct, CPV-IL Technical data – Fieldbus node CPV-IL CPV fieldbus node for communication between a CPV valve terminal and an Interbus Loop bus terminal. The fieldbus node is used for activation of a CPV valve terminal with 8 valve slices and 16 solenoid coils and for displaying the switching status via LED. TheCPV-…valvesareactivatedusing automatic current reduction, which resultsinlesspowerconsumption and heat emission. The CPV fieldbus node supports the fieldbus protocol Interbus Loop2. TheCPVfieldbusnodeisavailablein two sizes, with identical performance characteristics: CPV10 CPV14 Application Bus connection The Interbus loop connection uses “Quick On” technology with one connection each for the incoming and outgoing bus respectively. -H-Note It is not possible to connect a CP stringextensioninthiscase. -U-Typ e to be di sco n t i n u ed Available until 2007
Info 201 – Subject to change – 2004/1144 Fieldbus Direct, CPV-IL Technical data – Fieldbus node CPV-IL General technical data Ty p eCPV10-GE-IL-8CPV14-GE-IL-4CPV14-GE-IL-8 Part No.175 406188 450175 408 CP string extensionNo Baud rates[kbps]500 Protocol chipLPC2 Max. no. of loop stations63 Max. distance between 2 loop stations[m]20 Max. loop length[m]200 Max. loop current[A]1.8 Configuration supportIcon for CMD software Max. no. of solenoid coils16 Max. no. of outputs0 Max. no. of inputs0 LED diagnostic displaysDIAGBus statusgpy USUndervoltage 12Valve status display 14Valve status display Device-specific diagnosisUndervoltage of valves Operating voltageNominal value[V DC]24, reverse polarity protectedpgg Permissible range[V]20 … 30 Power failure buffering[ms]20 Residual ripple[Vss]4 Current consumption[mA]Max. 100 Protection class to EN 60 529IP65 ApprovalCE Temperature rangeOperating[°C]–5 … +50pg Storage[°C]–20 … +70 MaterialsHousingDie-cast aluminium Plug capPolyamide, glass fibre (Ultramide) SealNitrile rubber, Neoprene DimensionsInfo 213 Valve terminal CPV WeightInfo 213 Technical data for valvesInfo 213 -U-Typ e to be di sco n t i n u ed Available until 2007
2004/11 – Subject to change – Info 20145 Fieldbus Direct, CPV-IL Technical data – Fieldbus node CPV-IL Connection and display components 41 67 2 3 565 1BUS IN + 2BUS IN – 3BUS OUT + 4BUS IN – 524 V DC valve supply 60 V valve supply 7Earth terminal for valve supply Power supply The load supply for the valves is supplied using a separate Quick On connection, with one connection each for the incoming and outgoing supply respectively. -U-Typ e to be di sco n t i n u ed Available until 2007
Info 201 – Subject to change – 2004/1146 Fieldbus Direct, CPV-IL Accessories – Fieldbus node CPV-IL Ordering data DesignationTy p ePart No. Bus and power supply connection Quick On connection setFBS-IBL-PG11/13175 485 User documentation UserdocumentationforCPVDirect,CPVfieldbusnodeGermanP.BE-CP-IL-DE175 508, ILEnglishP.BE-CP-IL-EN175 509 FrenchP.BE-CP-IL-FR175 510 ItalianP.BE-CP-IL-IT175 511 SpanishP.BE-CP-IL-ES175 512 SwedishP.BE-CP-IL-SV175 513 Software CD-ROMValve terminal user documentation (PDF)P.CD-VALVE-T183 350 UtilitiesP.CD-VI-UTILITIES-2533 500 -U-Typ e to be di sco n t i n u ed Available until 2007
2004/11 – Subject to change – Info 20147 Fieldbus Direct, CPV-IP Technical data – Fieldbus node CPV-IP CPV fieldbus node for communication between a CPV valve terminal and an IP-Link coupler box. The fieldbus node is used for activation of a CPV valve terminal with 8 valve slices and 16 solenoid coils and for displaying the switching status via LED. TheCPV-…valvesareactivatedusing automatic current reduction, which resultsinlesspowerconsumption and heat emission. The CPV fieldbus node supports the fieldbus protocol IP-Link. TheCPVfieldbusnodeisavailablein two sizes, with identical performance characteristics: CPV10 CPV14 Application Bus connectionPower supply The bus connection is established using two IP-Link fibre optic cable connectors.The bus connector plugs (with protection class IP65) facilitate the connection of the incoming and outgoing fibre optic cable (FOC).The power is supplied via a 4-pin M8 connection (socket). The supply to the internal logic is fully electrically isolated from the supply to the solenoid coils.The second M8 connection (pin) allows power to be supplied to additional CPV IP-Link valve terminals and other IP-Link modules.
Info 201 – Subject to change – 2004/1148 Fieldbus Direct, CPV-IP Technical data – Fieldbus node CPV-IP General technical data Ty p eCPV10-GE-IP-8CPV14-GE-IP-8 Part No.534 509534 507 CP string extensionNo Fieldbus interfaceIP-Link Incoming, outgoing Baud rates[kbps]2000 Data modelCompact16 outputs Complex24 inputs 24 outputs Configuration supportProfibusGSD filegpp InterbusNot necessary CANopenEDS file DeviceNetEDS file Max. no. of solenoid coils16 LED diagnostic displaysUSOperating voltage, internal logicgpy UPOperating voltage, valves RUNBus active ERRData transmission error Device-specific diagnosisIn complex mode: Monitoring of valve undervoltage ParameterisationVia register communication: Setting via watchdog for coils 1 … 16 Operating voltageNominal value[V DC]24, reverse polarity protectedpgg Permissible range[V]20.4 … 28.8 Power failure buffering[ms]10 Residual ripple[Vss]4 Current consumptionLogic[mA]Max. 100p ValvesDepending on valve type Protection class to EN 60 529IP65 ApprovalCE Temperature rangeOperating[°C]–5 … +50pg Storage[°C]–20 … +70 MaterialsHousingDie-cast aluminium Plug capPolyamide, glass fibre (Ultramide) SealNitrile rubber, Neoprene DimensionsInfo 213 Valve terminal CPV WeightInfo 213 Technical data for valvesInfo 213
2004/11 – Subject to change – Info 20149 Fieldbus Direct, CPV-IP Technical data – Fieldbus node CPV-IP Connection and display components 1 2 3 4 5 6 1Connection for power supply, incoming (M8, 4-pin, plug) 2Connection for power supply, outgoing (M8, 4-pin, socket) 3LEDs: –US:Operatingvoltage, electronics (green) – UP: Load voltage, valves (green) – RUN: Bus active (green) – ERR: Error (red) 4Fieldbus connection, incoming (IP-Link fibre optic cable IP65 socket) 5Fieldbus connection, outgoing (IP-Link fibre optic cable IP65 socket) 6LEDs (yellow) for switching status display of CP solenoid coils Power supply, incoming PinSignal 124 V DC operating voltage, electronics (US) 224VDCloadvoltage,valves(UP) 30 V electronics (US) 40Vvalves(UP) Power supply, outgoing PinSignal 124 V DC operating voltage, electronics (US) 224VDCloadvoltage,valves(UP) 30 V electronics (US) 40Vvalves(UP)
Info 201 – Subject to change – 2004/1150 Fieldbus Direct, CPV-IP Technical data – Fieldbus node CPV-IP Equipotential bonding Example of connection with electrical isolation of operating and load voltage with 2 PELV power supply units 1 2 12 1412 14 12 14 12 14 12 14 12 14 12 14 12 14 Us UpRun ErrIP--L 24V 12 1412 14 12 14 12 14 12 14 12 14 12 14 12 14 Us UpRun ErrIP--L 24V 3412 3 1Power supply unit for load voltage 2Device for isolation monitoring 3Power supply unit for operating voltage CPV Direct is prepared for the connection with electrical isolation of operating and load voltage. Example of connection with PELV power supply unit and equipotential bonding 12 34 12 1PE and equipotential bonding 2Load voltage (can be disconnected separately) plus external fuses TheCPVvalveterminalhasanearth terminal for equipotential bonding on the end plate. Ordering data DesignationTy p ePart No. User documentation UserdocumentationforCPVDirect,CPVfieldbusnode IPGermanP.BE-CPV-DI-IP-DE534 516 IPEnglishP.BE-CPV-DI-IP-EN534 517 Software CD-ROMValve terminal user documentation (PDF)P.CD-VALVE-T183 350 UtilitiesP.CD-VI-UTILITIES-2533 500