Home > GE > Alarm system > GE Cpv14di018 Manual

GE Cpv14di018 Manual

    Download as PDF Print this page Share this page

    Have a look at the manual GE Cpv14di018 Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 45 GE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							2004/11 – Subject to change – Info 20141
    Fieldbus Direct, CPV-IB
    Technical data – Fieldbus node CPV-IB
    Connection and display components
    1
    2
    4
    5 3
    6
    789
    1Red LED: Dia (diagnosis)
    2Green LED: Pow (power supply
    indicator)
    3Green LED: RC (remotebus check)
    4Green LED: UL (voltage supply to
    Interbus)
    5Green LED: BA (bus active)
    6Yellow LED: RD (remotebus
    disable)
    7Switching status displays of CPV
    solenoid coils
    8CP extension connection
    9Interbus connection
    Pin allocation for Interbus interface, incoming (plug view)
    PinSignalDesignation
    1DO1Data out
    2/DI1Data in
    3GNDReference conductor/earth
    4n.c.Not connected
    5n.c.Not connected
    6/DO1Data out inverse
    7/DI1Data in inverse
    8n.c.Not connected
    9n.c.Not connected
    HousingScreenConnection to functional earth via R-C combination
    Pin allocation for Interbus interface, outgoing (socket view)
    PinSignalDesignation
    1DO2Data out
    2/DI2Data in
    3GNDReference conductor/earth
    4n.c.Not connected
    5+5 VStation detection1)
    6/DO2Data out inverse
    7/DI2Data in inverse
    8n.c.Not connected
    9RBSTStation detection1)
    HousingScreenConnection to functional earth via R-C combination
    1) The incoming interface is electrically isolated from the CPX peripherals. The plug housing is connected to the FE of the CPX terminal via an R-C combination.
    The CPX terminal contains the protocol chip SUPI3 OPC. This ensures automatic detection ofadditional connected Interbus stations. There is therefore no need for a bridge between pin 5 and pin 9. 
    						
    							Info 201 – Subject to change – 2004/1142
    Fieldbus Direct, CPV-IB
    Accessories – Fieldbus node CPV-IB
    Ordering data
    DesignationTy p ePart No.
    Power supply
    Power supply socket, straightFBSD-GD-718 497
    FBSD-GD-918 495
    Power supply socket, angledFBSD-WD-718 524
    FBSD-WD-918 525
    Bus connection
    Fieldbus plug, Sub-D connection for Interbus incomingFBS-SUB-9-BU-IB-B532 218
    Fieldbus plug, Sub-D connection for Interbus outgoingFBS-SUB-9-GS-IB-B532 217
    Mounting screw for standard Sub- D (IP20)UNC 4-40/M3x5340 960
    Valve terminal connection
    Connecting cable WS-WD0.5 mKVI-CP-1-WS-WD-0,5178 564g
    1mKVI-CP-1-WS-WD-1.0191 892
    2mKVI-CP-1-WS-WD-2163 139
    3mKVI-CP-1-WS-WD-3.0191 893
    5mKVI-CP-1-WS-WD-5163 138
    Connecting cable GS-WD5mKVI-CP-1-GS-WD-5163 137
    8mKVI-CP-1-GS-WD-8163 136
    Connecting cable GS-GD2 m, for chain link trunkingKVI-CP-2-GS-GD-2170 234g
    5 m, for chain link trunkingKVI-CP-2-GS-GD-5170 235
    8 m, for chain link trunkingKVI-CP-2-GS-GD-8165 616
    User documentation
    UserdocumentationforCPVDirect,CPVfieldbusnodeGermanP.BE-CP-IB-DE527 515,
    IBEnglishP.BE-CP-IB-EN527 516
    SpanishP.BE-CP-IB-ES527 517
    FrenchP.BE-CP-IB-FR527 518
    ItalianP.BE-CP-IB-IT527 519
    SwedishP.BE-CP-IB-SV527 520
    Software
    CD-ROMValve terminal user
    documentation (PDF)P.CD-VALVE-T183 350
    UtilitiesP.CD-VI-UTILITIES-2533 500 
    						
    							2004/11 – Subject to change – Info 20143
    Fieldbus Direct, CPV-IL
    Technical data – Fieldbus node CPV-IL
    CPV fieldbus node for communication
    between a CPV valve terminal and an
    Interbus Loop bus terminal. The
    fieldbus node is used for activation of
    a CPV valve terminal with 8 valve
    slices and 16 solenoid coils and for
    displaying the switching status via
    LED.
    TheCPV-…valvesareactivatedusing
    automatic current reduction, which
    resultsinlesspowerconsumption
    and heat emission.
    The CPV fieldbus node supports the
    fieldbus protocol Interbus Loop2.
    TheCPVfieldbusnodeisavailablein
    two sizes, with identical performance
    characteristics:
    CPV10
    CPV14
    Application
    Bus connection
    The Interbus loop connection uses
    “Quick On” technology with one
    connection each for the incoming and
    outgoing bus respectively.
    -H-Note
    It is not possible to connect a CP
    stringextensioninthiscase.
    -U-Typ e to be di sco n t i n u ed
    Available until 2007 
    						
    							Info 201 – Subject to change – 2004/1144
    Fieldbus Direct, CPV-IL
    Technical data – Fieldbus node CPV-IL
    General technical data
    Ty p eCPV10-GE-IL-8CPV14-GE-IL-4CPV14-GE-IL-8
    Part No.175 406188 450175 408
    CP string extensionNo
    Baud rates[kbps]500
    Protocol chipLPC2
    Max. no. of loop stations63
    Max. distance between 2 loop stations[m]20
    Max. loop length[m]200
    Max. loop current[A]1.8
    Configuration supportIcon for CMD software
    Max. no. of solenoid coils16
    Max. no. of outputs0
    Max. no. of inputs0
    LED diagnostic displaysDIAGBus statusgpy
    USUndervoltage
    12Valve status display
    14Valve status display
    Device-specific diagnosisUndervoltage of valves
    Operating voltageNominal value[V DC]24, reverse polarity protectedpgg
    Permissible range[V]20 … 30
    Power failure buffering[ms]20
    Residual ripple[Vss]4
    Current consumption[mA]Max. 100
    Protection class to EN 60 529IP65
    ApprovalCE
    Temperature rangeOperating[°C]–5 … +50pg
    Storage[°C]–20 … +70
    MaterialsHousingDie-cast aluminium
    Plug capPolyamide, glass fibre (Ultramide)
    SealNitrile rubber, Neoprene
    DimensionsInfo 213 Valve terminal CPV
    WeightInfo 213
    Technical data for valvesInfo 213
    -U-Typ e to be di sco n t i n u ed
    Available until 2007 
    						
    							2004/11 – Subject to change – Info 20145
    Fieldbus Direct, CPV-IL
    Technical data – Fieldbus node CPV-IL
    Connection and display components
    41
    67
    2
    3
    565
    1BUS IN +
    2BUS IN –
    3BUS OUT +
    4BUS IN –
    524 V DC valve supply
    60 V valve supply
    7Earth terminal for valve supply
    Power supply
    The load supply for the valves is
    supplied using a separate Quick On
    connection, with one connection each
    for the incoming and outgoing supply
    respectively.
    -U-Typ e to be di sco n t i n u ed
    Available until 2007 
    						
    							Info 201 – Subject to change – 2004/1146
    Fieldbus Direct, CPV-IL
    Accessories – Fieldbus node CPV-IL
    Ordering data
    DesignationTy p ePart No.
    Bus and power supply connection
    Quick On connection setFBS-IBL-PG11/13175 485
    User documentation
    UserdocumentationforCPVDirect,CPVfieldbusnodeGermanP.BE-CP-IL-DE175 508,
    ILEnglishP.BE-CP-IL-EN175 509
    FrenchP.BE-CP-IL-FR175 510
    ItalianP.BE-CP-IL-IT175 511
    SpanishP.BE-CP-IL-ES175 512
    SwedishP.BE-CP-IL-SV175 513
    Software
    CD-ROMValve terminal user
    documentation (PDF)P.CD-VALVE-T183 350
    UtilitiesP.CD-VI-UTILITIES-2533 500
    -U-Typ e to be di sco n t i n u ed
    Available until 2007 
    						
    							2004/11 – Subject to change – Info 20147
    Fieldbus Direct, CPV-IP
    Technical data – Fieldbus node CPV-IP
    CPV fieldbus node for communication
    between a CPV valve terminal and an
    IP-Link coupler box. The fieldbus node
    is used for activation of a CPV valve
    terminal with 8 valve slices and
    16 solenoid coils and for displaying
    the switching status via LED.
    TheCPV-…valvesareactivatedusing
    automatic current reduction, which
    resultsinlesspowerconsumption
    and heat emission.
    The CPV fieldbus node supports the
    fieldbus protocol IP-Link.
    TheCPVfieldbusnodeisavailablein
    two sizes, with identical performance
    characteristics:
    CPV10
    CPV14
    Application
    Bus connectionPower supply
    The bus connection is established
    using two IP-Link fibre optic cable
    connectors.The bus connector plugs (with
    protection class IP65) facilitate the
    connection of the incoming and
    outgoing fibre optic cable (FOC).The power is supplied via a 4-pin M8
    connection (socket). The supply to the
    internal logic is fully electrically
    isolated from the supply to the
    solenoid coils.The second M8 connection (pin)
    allows power to be supplied to
    additional CPV IP-Link valve terminals
    and other IP-Link modules. 
    						
    							Info 201 – Subject to change – 2004/1148
    Fieldbus Direct, CPV-IP
    Technical data – Fieldbus node CPV-IP
    General technical data
    Ty p eCPV10-GE-IP-8CPV14-GE-IP-8
    Part No.534 509534 507
    CP string extensionNo
    Fieldbus interfaceIP-Link
    Incoming, outgoing
    Baud rates[kbps]2000
    Data modelCompact16 outputs
    Complex24 inputs
    24 outputs
    Configuration supportProfibusGSD filegpp
    InterbusNot necessary
    CANopenEDS file
    DeviceNetEDS file
    Max. no. of solenoid coils16
    LED diagnostic displaysUSOperating voltage, internal logicgpy
    UPOperating voltage, valves
    RUNBus active
    ERRData transmission error
    Device-specific diagnosisIn complex mode:
    Monitoring of valve undervoltage
    ParameterisationVia register communication:
    Setting via watchdog for coils 1 … 16
    Operating voltageNominal value[V DC]24, reverse polarity protectedpgg
    Permissible range[V]20.4 … 28.8
    Power failure buffering[ms]10
    Residual ripple[Vss]4
    Current consumptionLogic[mA]Max. 100p
    ValvesDepending on valve type
    Protection class to EN 60 529IP65
    ApprovalCE
    Temperature rangeOperating[°C]–5 … +50pg
    Storage[°C]–20 … +70
    MaterialsHousingDie-cast aluminium
    Plug capPolyamide, glass fibre (Ultramide)
    SealNitrile rubber, Neoprene
    DimensionsInfo 213 Valve terminal CPV
    WeightInfo 213
    Technical data for valvesInfo 213 
    						
    							2004/11 – Subject to change – Info 20149
    Fieldbus Direct, CPV-IP
    Technical data – Fieldbus node CPV-IP
    Connection and display components
    1
    2
    3
    4
    5
    6
    1Connection for power supply,
    incoming (M8, 4-pin, plug)
    2Connection for power supply,
    outgoing (M8, 4-pin, socket)
    3LEDs:
    –US:Operatingvoltage,
    electronics (green)
    – UP: Load voltage, valves
    (green)
    – RUN: Bus active (green)
    – ERR: Error (red)
    4Fieldbus connection, incoming
    (IP-Link fibre optic cable IP65
    socket)
    5Fieldbus connection, outgoing
    (IP-Link fibre optic cable IP65
    socket)
    6LEDs (yellow) for switching status
    display of CP solenoid coils
    Power supply, incoming
    PinSignal
    124 V DC operating voltage, electronics (US)
    224VDCloadvoltage,valves(UP)
    30 V electronics (US)
    40Vvalves(UP)
    Power supply, outgoing
    PinSignal
    124 V DC operating voltage, electronics (US)
    224VDCloadvoltage,valves(UP)
    30 V electronics (US)
    40Vvalves(UP) 
    						
    							Info 201 – Subject to change – 2004/1150
    Fieldbus Direct, CPV-IP
    Technical data – Fieldbus node CPV-IP
    Equipotential bonding
    Example of connection with electrical isolation of operating and load voltage with 2 PELV power supply units
    1
    2
    12
    1412
    14 12
    14 12
    14 12
    14 12
    14 12
    14 12
    14
    Us
    UpRun
    ErrIP--L 24V
    12
    1412
    14 12
    14 12
    14 12
    14 12
    14 12
    14 12
    14
    Us
    UpRun
    ErrIP--L 24V
    3412
    3
    1Power supply unit for load
    voltage
    2Device for isolation monitoring
    3Power supply unit for operating
    voltage
    CPV Direct is prepared for the
    connection with electrical isolation of
    operating and load voltage.
    Example of connection with PELV power supply unit and equipotential bonding
    12
    34 12
    1PE and equipotential bonding
    2Load voltage (can be
    disconnected separately) plus
    external fuses
    TheCPVvalveterminalhasanearth
    terminal for equipotential bonding on
    the end plate.
    Ordering data
    DesignationTy p ePart No.
    User documentation
    UserdocumentationforCPVDirect,CPVfieldbusnode
    IPGermanP.BE-CPV-DI-IP-DE534 516
    IPEnglishP.BE-CPV-DI-IP-EN534 517
    Software
    CD-ROMValve terminal user
    documentation (PDF)P.CD-VALVE-T183 350
    UtilitiesP.CD-VI-UTILITIES-2533 500 
    						
    All GE manuals Comments (0)

    Related Manuals for GE Cpv14di018 Manual