2004/11 – Subject to change – Info 20111 Fieldbus Direct, CPV-DI01 Technical data – Fieldbus node CPV-DI01 Connection and display components 1 2 4 3 1Red LED: Bus status/error (BUS) 2Green LED: Power supply (POWER) 3Yellow LED row: For pilot solenoid coils 12 4Yellow LED row: For pilot solenoid coils 14 Pin allocation for fieldbus interface (plug view) PinFesto Sub- DManufacturer-specific signal designation plug (IP65)Festo fieldbusABB CS31PROFIBUS DPMoeller SUCONET K interface 3 Sub- D, 9- pinDIN (round) 5- pin 1n.c. 2n.c. 3BS+Bus1RxD/TxD-P3(TA/RA)4(TA/RA) 4CNTR-P 5DGND 6VP 7n.c. 8AS-Bus2RxD/TxD-N7(TB/RB)1(TB/RB) 9n.c. HousingCable clipScreenScreenScreen4 (screen)Housing Pin allocation for M12 adapter Profibus DP (signal)Bus In (pin)Bus Out (socket)Designation ScreenM12 and 5M12 and 5Screen or functional earthing RxD / TxD-P44Data B DGND-3Reference potential to supply voltage plus (VP) VP (P5V)-1Supply voltage – Plus RxD / TxD-N22Data A
Info 201 – Subject to change – 2004/1112 Fieldbus Direct, CPV-DI01 Accessories – Fieldbus node CPV-DI01 Ordering data DesignationTy p ePart No. Power supply Power supply socket, straightFBSD-GD-718 497 FBSD-GD-918 495 Power supply socket, angledFBSD-WD-718 524 FBSD-WD-918 525 Fieldbus connection Fieldbus socket, Sub- D connectionFBS-Sub-9-GS-DP-B532 216 M12 adapterFBA-2-M12-5POL-RK533 118 Valve terminal connection Connecting cable WS-WD0.5 mKVI-CP-1-WS-WD-0,5178 564g 1mKVI-CP-1-WS-WD-1.0191 892 2mKVI-CP-1-WS-WD-2163 139 3mKVI-CP-1-WS-WD-3.0191 893 5mKVI-CP-1-WS-WD-5163 138 Connecting cable GS-WD5mKVI-CP-1-GS-WD-5163 137 8mKVI-CP-1-GS-WD-8163 136 Connecting cable GS-GD2 m, for chain link trunkingKVI-CP-2-GS-GD-2170 234g 5 m, for chain link trunkingKVI-CP-2-GS-GD-5170 235 8 m, for chain link trunkingKVI-CP-2-GS-GD-8165 616 User documentation UserdocumentationforCPVDirect,CPVfieldbusnodeGermanP.BE-CP-DI01-DE165 816, DI01EnglishP.BE-CP-DI01-EN165 817 ItalianP.BE-CP-DI01-IT165 818 FrenchP.BE-CP-DI01-FR165 819 SpanishP.BE-CP-DI01-ES165 820 SwedishP.BE-CP-DI01-SV165 821 Software CD-ROMValve terminal user documentation (PDF)P.CD-VALVE-T183 350 UtilitiesP.CD-VI-UTILITIES-2533 500
2004/11 – Subject to change – Info 20113 Fieldbus Direct, CPV-DN2 Technical data – Fieldbus node CPV-DN2 CPV fieldbus node for communication between a CPV valve terminal and a fieldbusmaster.Thefieldbusnodeis used for activation of a CPV valve terminal with 8 valve slices and 16 solenoid coils and for displaying the switching status via LED. TheCPV-…valvesareactivatedusing automatic current reduction, which resultsinlesspowerconsumption and heat emission. 16 digital inputs and 8 digital outputs or 16 solenoid coils can be connected via a serial CP string extension. The CPV fieldbus node supports the DeviceNet protocol and conforms to the equipment profile of the pneumatic valve. TheCPVfieldbusnodeisavailablein three sizes, with identical performance characteristics: CPV10 CPV14 CPV18 Application Bus connection Micro Style Open Style Open Style 5- pin terminal strip For installations in protected environments (IP20) Open Style offers a 5-pin row with the DeviceNet pin allocation. If the valve terminal is ordered with this bus connection, the 5-pin screw terminal strip will also be supplied. It is designed with double screw terminals for the incoming and the outgoing bus cable. This connection technology provides the function of a T-distributor.Micro Style Push-in connector 2xM12 Installation with IP65 protection Micro Style is prepared for connecting through the bus cable with an M12 plug for the incoming cable and a socket for the outgoing bus cable. The bus connection fulfils the require- ment of a T-distributor, this means that the CPV valve terminal can be disconnected from the DeviceNet with- out interrupting the bus. This method of direct connection does away with the need for the branch line length in the DeviceNet configuration.
Info 201 – Subject to change – 2004/1114 Fieldbus Direct, CPV-DN2 Technical data – Fieldbus node CPV-DN2 Condition monitoring Condition monitoring supports the preventative maintenance of the func- tionchaininautomationsystems. Each valve is assigned a switching cycle counter that automaticallyregisters movements of the system components. Once a maximum number of activations is reached, a message issent to the controller via DeviceNet and maintenance can be started. In the same way condition monitoring supports the determination of theservice intervals for the function chain. All movements immediately after installation are registered. General technical data Ty p eCPV10-GE-DN2-8CPV14-GE-DN2-8CPV18-GE-DN2-8 Part No.525 630525 878525 880 CP string extensionYes 16 inputs and 8 outputs (or 16 valves) Baud rates[kbps]125, 250, 500 Addressing range0…63 Set using switch module Product familyPneumatic valve (27 dec.) Ident. number8942 dec. Type of communicationPolling, change of state, strobed I/O Configuration supportEDS file and graphics symbol Max. no. of solenoid coils2x16 Max. no. of outputs8 (1x16 solenoid coils omitted) Max. no. of inputs16 LED diagnostic displaysPSCommon message concerning supply voltagegpy MNSDeviceNet status Device-specific diagnosis via DeviceNetShort circuit/overload of outputs Short circuit/overload of inputs Undervoltage of valve terminal Undervoltage of valve terminal (extension) Undervoltage of output module Undervoltage of sensor supply Missing module on CP string Condition monitoring Operating voltageNominal value[V]24 DC, reverse polarity protectedpgg Permissible range[V]20.4 … 26.4 DC Power failure buffering[ms]20 Current consumption[mA]Max. 200 + sensor supply Protection class to EN 60 529IP65 ApprovalCE Temperature rangeOperating[°C]–5 … +50pg Storage[°C]–20 … +60 MaterialsHousingDie-cast aluminium Plug capPolyamide, glass fibre (Ultramide) SealNitrile rubber, Neoprene DimensionsInfo 213 Valve terminal CPV WeightInfo 213 Technical data for valvesInfo 213
2004/11 – Subject to change – Info 20115 Fieldbus Direct, CPV-DN2 Technical data – Fieldbus node CPV-DN2 Connection and display components 1 5 2 3 4 61Interchangeable fieldbus connection: – Micro Style connection (2xM12) – Open Style connection (terminal strip) –9-pinSub-Dplug 2Switch module (removable) 3Connection for voltage supply (4-pin M12 plug, operating voltage for electronics, load voltage for CP valves) 4LEDs: –Powerstatus(PS) – Module/network status (MNS) 5CP extension connection 6Switching status displays of CPV solenoid coils Pin allocation for M12 adapter PinSignal-specific core colourSignalDesignation 1blankScreenConnection to housing 2red24 V DC bus24 V supply CAN interface 3black0Vbus0VCANinterface 4whiteCAN_HReceived/transmitted data high 5blueCAN_LReceived/transmitted data low Pin allocation for Open Style adapter PinSignal-specific core colourSignalDesignation 1black0Vbus0VCANinterface 2blueCAN_LReceived/transmitted data low 3blankScreenConnection to housing 4whiteCAN_HReceived/transmitted data high 5red24 V DC bus24 V DC supply CAN interface
Info 201 – Subject to change – 2004/1116 Fieldbus Direct, CPV-DN2 Accessories – Fieldbus node CPV-DN2 Ordering data DesignationTy p ePart No. Power supply Power supply socket, straightFBSD-GD-718 497 FBSD-GD-918 495 Power supply socket, angledFBSD-WD-718 524 FBSD-WD-918 525 Bus connection Micro Style M12 Bus connection Micro Style, 2xM12FBA-2-M12-5POL525 632 Fieldbus socket for Micro Style connection, M12, 5-pin, straightFBSD-GD-9-5POL18 324 Plug for Micro Style connection, M12, 5-pin, straightFBS-M12-5GS-PG9175 380 Bus connection Open Style, 5-pin screw terminal strip Bus connection Open Style for 5-pin terminal stripFBA-1-SL-5POL525 634 Bus connection, 5-pin terminal stripFBSD-KL-2x5POL525 635 Valve terminal connection Connecting cable WS-WD0.5 mKVI-CP-1-WS-WD-0,5178 564g 1mKVI-CP-1-WS-WD-1.0191 892 2mKVI-CP-1-WS-WD-2163 139 3mKVI-CP-1-WS-WD-3.0191 893 5mKVI-CP-1-WS-WD-5163 138 Connecting cable GS-WD5mKVI-CP-1-GS-WD-5163 137 8mKVI-CP-1-GS-WD-8163 136 Connecting cable GS-GD2 m, for chain link trunkingKVI-CP-2-GS-GD-2170 234g 5 m, for chain link trunkingKVI-CP-2-GS-GD-5170 235 8 m, for chain link trunkingKVI-CP-2-GS-GD-8165 616 User documentation UserdocumentationforCPVDirect,CPVfieldbusnodeGermanP.BE-CP-DN2-DE526 016, DN2EnglishP. B E - C P - D N 2 - E N526 017 ItalianP. B E - C P - D N 2 - I T526 018 FrenchP. B E - C P - D N 2 - F R526 019 SpanishP. B E - C P - D N 2 - E S526 020 SwedishP. B E - C P - D N 2 - S V526 021 Software CD-ROMValve terminal user documentation (PDF)P.CD-VALVE-T183 350 UtilitiesP.CD-VI-UTILITIES-2533 500
2004/11 – Subject to change – Info 20117 Fieldbus Direct, CPASC1-AE32-DN Technical data – Fieldbus node CPASC1-AE32-DN CPASC1 fieldbus node for communica- tion between a CPASC1 valve terminal and a fieldbus master. The fieldbus node is used for activation of a CPASC1 valve terminal with up to 32 solenoid coils on max. 24 valve positions and for displaying the switching status via LED. TheCPASC1…valvesareactivated using automatic current reduction, which results in less power consump- tion and heat emission. 16 digital inputs and 8 digital outputs or 16 solenoid coils can be connected via a serial CP string extension. TheCPASC1fieldbusnodesupports the DeviceNet protocol and conforms to the equipment profile of the pneumatic valve. Application Bus connection The DeviceNet connection is estab- lished via a 5-pin M12 plug with pins that corresponds to the specific mini connector. A DeviceNet installation with a higher degree of protection is typically configured using main and branch lines that are connected via T- pieces.Various manufacturers such as Turck, Lumberg and Rockwell offer finished cables and terminating resistors. The terminating resistors are attached to the two outermost T-pieces. This installation technique keeps the bus closed while a bus station is being removed.In order to prevent confusion when establishing a connection to the field- bus, a Micro Style M12, 5-pin plug connector with a straight socket (A-coded) is used. A Micro Style M12, 5- pin plug connector with a straight socket (B- coded) is used for the power supply.
Info 201 – Subject to change – 2004/1118 Fieldbus Direct, CPASC1-AE32-DN Technical data – Fieldbus node CPASC1-AE32-DN Condition monitoring Condition monitoring supports the preventative maintenance of the func- tionchaininautomationsystems. Each valve is assigned a switching cycle counter that automaticallyregisters movements of the system components. Once a maximum number of activations is reached, a message issent to the controller via DeviceNet and maintenance can be started. In the same way condition monitoring supports the determination of theservice intervals for the function chain. All movements immediately after installation are registered. General technical data Ty p eCPASC1 -AE3 2 -DN Part No.538 652 CP string extensionYes 16 inputs and 8 outputs (or 16 valves) Baud rates[kbps]125, 250, 500 Addressing range0…63 Set using switch module Product familyPneumatic valve (27 dec.) Ident. number5250 dec. Type of communicationPolling, change of state, strobed I/O Configuration supportEDS file and graphics symbol Max. no. of solenoid coils32+16 Max. no. of outputs8 (1x16 solenoid coils omitted) Max. no. of inputs16 LED diagnostic displaysPSCommon message concerning supply voltagegpy PLPower supply for valves SFCP system error NETDeviceNet network status MODDeviceNet module status Device-specific diagnosis via DeviceNetShort circuit/overload of outputs Short circuit/overload of inputs Undervoltage of valve terminal Undervoltage of valve terminal (extension) Undervoltage of output module Undervoltage of sensor supply Missing module on CP string Condition monitoring Operating voltageNominal value[V]24 DC, reverse polarity protectedpgg Permissible range[V]20.4 … 26.4 DC Power failure buffering[ms]20 Current consumption[mA]Max. 200 + sensor supply Residual ripple[Vss]4 Protection class to EN 60 529IP40 (with fitted cover) Vibration resistanceTo EN 60 068-2-6: Wall mounting class 2 H-rail mounting class 1 Shock resistanceTo EN 60 068-2-27: Wall mounting class 2 H-rail mounting class 1 To EN 60 068-2-29: Wall mounting class 1 H-rail mounting class 1 ApprovalCE Temperature rangeOperating[°C]–5 … +50pg Storage[°C]–20 … +50 MaterialsPolymer DimensionsInfo 211 WeightInfo 211 Technical data for valvesInfo 211
2004/11 – Subject to change – Info 20119 Fieldbus Direct, CPASC1-AE32-DN Technical data – Fieldbus node CPASC1-AE32-DN Connection and display components 654732181Connection for CP extension 2Connection for power supply 3Connection for fieldbus 4DIL switch for CP extension 5Rotary switch for baud rate 6Rotary switch for station number 7Earth terminal 8Cover (for IP40 protection) Pin allocation for fieldbus interface PinSignal-specific core colourSignalDesignation 1blankScreenConnection to housing 2red24 V DC bus24 V supply CAN interface 3black0Vbus0VCANinterface 4whiteCAN_HReceived/transmitted data high 5blueCAN_LReceived/transmitted data low
Info 201 – Subject to change – 2004/1120 Fieldbus Direct, CPASC1-AE32-DN Accessories – Fieldbus node CPASC1-AE32-DN Ordering data DesignationTy p ePart No. Power supply Micro Style M12 Power supply socket, for Micro Style connection, M12, 5-pin, straight socket (B-coded)NTSD-GD-9-M12-5POL-RK538 999 Bus connection Micro Style M12 Fieldbus socket for Micro Style connection, M12, 5- pin, straight socket (A- coded)FBSD-GD-9-5POL18 324 Valve terminal connection Connecting cable with angled plug and angled socket0.5 mKVI-CP-1-WS-WD-0,5178 564ggpgg 1mKVI-CP-1-WS-WD-1.0191 892 2mKVI-CP-1-WS-WD-2163 139 3mKVI-CP-1-WS-WD-3.0191 893 5mKVI-CP-1-WS-WD-5163 138 Connecting cable with straight plug and angled socket5mKVI-CP-1-GS-WD-5163 137 8mKVI-CP-1-GS-WD-8163 136 Connecting cable with straight plug and straight socket2 m, for chain link trunkingKVI-CP-2-GS-GD-2170 234ggpgg 5 m, for chain link trunkingKVI-CP-2-GS-GD-5170 235 8 m, for chain link trunkingKVI-CP-2-GS-GD-8165 616 User documentation UserdocumentationforCPVDirect,CPVfieldbusnodeGermanP.BE-CPASC-CPVSC-DE539 008, DN2EnglishP.BE-CPASC-CPVSC-EN539 009 ItalianP.BE-CPASC-CPVSC-IT539 010 FrenchP.BE-CPASC-CPVSC-FR539 011 SpanishP.BE-CPASC-CPVSC-ES539 012 SwedishP.BE-CPASC-CPVSC-SV539 013 Software CD-ROMValve terminal user documentation (PDF)P.CD-VALVE-T183 350 UtilitiesP.CD-VI-UTILITIES-2533 500