2004/11 – Subject to change – Info 20121 Fieldbus Direct, CPVSC1-AE16-DN Technical data – Fieldbus node CPVSC1-AE16-DN CPVSC1 fieldbus node for communica- tion between a CPVSC1 valve terminal and a fieldbus master. The fieldbus node is used for activation of a CPVSC1 valve terminal with up to 16 solenoid coils on max. 16 valve positions and for displaying the switching status via LED. TheCPVSC1…valvesareactivated using automatic current reduction, which results in less power consump- tion and heat emission. 16 digital inputs and 8 digital outputs or 16 solenoid coils can be connected via a serial CP string extension. TheCPVSC1fieldbusnodesupports the DeviceNet protocol and conforms to the equipment profile of the pneumatic valve. Application Bus connection The DeviceNet connection is estab- lished via a 5-pin M12 plug with pins that corresponds to the specific mini connector. A DeviceNet installation with a higher degree of protection is typically configured using main and branch lines that are connected via T- pieces.Various manufacturers such as Turck, Lumberg and Rockwell offer finished cables and terminating resistors. The terminating resistors are attached to the two outermost T-pieces. This installation technique keeps the bus closed while a bus station is being removed.In order to prevent confusion when establishing a connection to the field- bus, a Micro Style M12, 5-pin plug connector with a straight socket (A-coded) is used. A Micro Style M12, 5- pin plug connector with a straight socket (B- coded) is used for the power supply.
Info 201 – Subject to change – 2004/1122 Fieldbus Direct, CPVSC1-AE16-DN Technical data – Fieldbus node CPVSC1-AE16-DN Condition monitoring Condition monitoring supports the preventative maintenance of the func- tionchaininautomationsystems. Each valve is assigned a switching cycle counter that automaticallyregisters movements of the system components. Once a maximum number of activations is reached, a message issent to the controller via DeviceNet and maintenance can be started. In the same way condition monitoring supports the determination of theservice intervals for the function chain. All movements immediately after installation are registered. General technical data Ty p eCPVSC1 -AE1 6 -DN Part No.538 654 CP string extensionYes 16 inputs and 8 outputs (or 16 valves) Baud rates[kbps]125, 250, 500 Addressing range0…63 Set using switch module Product familyPneumatic valve (27 dec.) Ident. number4736 dec. Type of communicationPolling, change of state, strobed I/O Configuration supportEDS file and graphics symbol Max. no. of solenoid coils2x16 Max. no. of outputs8 (1x16 solenoid coils omitted) Max. no. of inputs16 LED diagnostic displaysPSCommon message concerning supply voltagegpy PLPower supply for valves SFCP system error NETDeviceNet network status MODDeviceNet module status Device-specific diagnosis via DeviceNetShort circuit/overload of outputs Short circuit/overload of inputs Undervoltage of valve terminal Undervoltage of valve terminal (extension) Undervoltage of output module Undervoltage of sensor supply Missing module on CP string Condition monitoring Operating voltageNominal value[V]24 DC, reverse polarity protectedpgg Permissible range[V]20.4 … 26.4 DC Power failure buffering[ms]20 Current consumption[mA]Max. 200 + sensor supply Residual ripple[Vss]4 Protection class to EN 60 529IP40 (with fitted cover) Vibration resistanceTo EN 60 068-2-6: Wall mounting class 2 H-rail mounting class 1 Shock resistanceTo EN 60 068-2-27: Wall mounting class 2 H-rail mounting class 1 To EN 60 068-2-29: Wall mounting class 1 H-rail mounting class 1 ApprovalCE Temperature rangeOperating[°C]–5 … +50pg Storage[°C]–20 … +50 MaterialsPolymer DimensionsInfo 226 WeightInfo 226 Technical data for valvesInfo 226
2004/11 – Subject to change – Info 20123 Fieldbus Direct, CPVSC1-AE16-DN Technical data – Fieldbus node CPVSC1-AE16-DN Connection and display components 654 73218 1Connection for CP extension 2Connection for power supply 3Connection for fieldbus 4DIL switch for CP extension 5Rotary switch for baud rate 6Rotary switch for station number 7Earth terminal 8Cover (for IP40 protection) Pin allocation for fieldbus interface PinSignal-specific core colourSignalDesignation 1blankScreenConnection to housing 2red24 V DC bus24 V supply CAN interface 3black0Vbus0VCANinterface 4whiteCAN_HReceived/transmitted data high 5blueCAN_LReceived/transmitted data low
Info 201 – Subject to change – 2004/1124 Fieldbus Direct, CPVSC1-AE16-DN Accessories – Fieldbus node CPVSC1-AE16-DN Ordering data DesignationTy p ePart No. Power supply Micro Style M12 Power supply socket, for Micro Style connection, M12, 5-pin, straight socket (B-coded)NTSD-GD-9-M12-5POL-RK538 999 Bus connection Micro Style M12 Fieldbus socket for Micro Style connection, M12, 5- pin, straight socket (A- coded)FBSD-GD-9-5POL18 324 Valve terminal connection Connecting cable with angled plug and angled socket0.5 mKVI-CP-1-WS-WD-0,5178 564ggpgg 1mKVI-CP-1-WS-WD-1.0191 892 2mKVI-CP-1-WS-WD-2163 139 3mKVI-CP-1-WS-WD-3.0191 893 5mKVI-CP-1-WS-WD-5163 138 Connecting cable with straight plug and angled socket5mKVI-CP-1-GS-WD-5163 137 8mKVI-CP-1-GS-WD-8163 136 Connecting cable with straight plug and straight socket2 m, for chain link trunkingKVI-CP-2-GS-GD-2170 234ggpgg 5 m, for chain link trunkingKVI-CP-2-GS-GD-5170 235 8 m, for chain link trunkingKVI-CP-2-GS-GD-8165 616 User documentation UserdocumentationforCPVDirect,CPVfieldbusnodeGermanP.BE-CPASC-CPVSC-DE539 008, DN2EnglishP.BE-CPASC-CPVSC-EN539 009 ItalianP.BE-CPASC-CPVSC-IT539 010 FrenchP.BE-CPASC-CPVSC-FR539 011 SpanishP.BE-CPASC-CPVSC-ES539 012 SwedishP.BE-CPASC-CPVSC-SV539 013 Software CD-ROMValve terminal user documentation (PDF)P.CD-VALVE-T183 350 UtilitiesP.CD-VI-UTILITIES-2533 500
2004/11 – Subject to change – Info 20125 Fieldbus Direct, CDVI-DN Technical data – Fieldbus node CDVI-DN CDVI fieldbus node for communication between a CDVI valve terminal and a fieldbusmaster.Thefieldbusnodeis used for activation of a CDVI valve terminal with up to 24 solenoid coils on max. 12 valve positions and for displaying the switching status via LED. The CDVI… valves are activated using automatic current reduction, which resultsinlesspowerconsumption and heat emission. 16 digital inputs and 8 digital outputs or 16 solenoid coils can be connected via a serial CP string extension. The CDVI fieldbus node supports the DeviceNet protocol and conforms to the equipment profile of the pneumatic valve. Application Bus connection The DeviceNet connection is estab- lished via a 5-pin M12 plug with pins that corresponds to the specific mini connector. A DeviceNet installation with a higher degree of protection is typically configured using main and branch lines that are connected via T- pieces.Various manufacturers such as Turck, Lumberg and Rockwell offer finished cables and terminating resistors. The terminating resistors are attached to the two outermost T-pieces. This installation technique keeps the bus closed while a bus station is being removed.In order to prevent confusion when establishing a connection to the field- bus, a Micro Style M12, 5-pin plug connector with a straight socket (A-coded) is used. A Micro Style M12, 5- pin plug connector with a straight socket (B- coded) is used for the power supply.
Info 201 – Subject to change – 2004/1126 Fieldbus Direct, CDVI-DN Technical data – Fieldbus node CDVI-DN Condition monitoring Condition monitoring supports the preventative maintenance of the func- tionchaininautomationsystems. Each valve is assigned a switching cycle counter that automaticallyregisters movements of the system components. Once a maximum number of activations is reached, a message issent to the controller via DeviceNet and maintenance can be started. In the same way condition monitoring supports the determination of theservice intervals for the function chain. All movements immediately after installation are registered. General technical data Ty p eCDVI-DN Part No.197 648 CP string extensionYes 16 inputs and 8 outputs (or 16 valves) Baud rates[kbps]125, 250, 500 Addressing range0…63 Set using switch module Product familyCommunication adapter (12 dec.) Ident. number5141 dec. Type of communicationPolling, change of state Configuration supportEDS file and graphics symbol Max. no. of solenoid coils24+16 Max. no. of outputs8 (1x16 solenoid coils omitted) Max. no. of inputs16 LED diagnostic displaysPSCommon message concerning supply voltagegpy PLPower supply for valves MNSDeviceNet module/network status CPCP extension modules Device-specific diagnosis via DeviceNetShort circuit/overload of outputs Short circuit/overload of inputs Undervoltage of valve terminal Undervoltage of valve terminal (extension) Undervoltage of output module Undervoltage of sensor supply Missing module on CP string Condition monitoring Operating voltageNominal value[V]24 DC, reverse polarity protectedpgg Permissible range[V]20.4 … 26.4 DC Power failure buffering[ms]20 Current consumption[mA]Max. 100 + sensor supply Residual ripple[Vss]4 Protection class to EN 60 529IP66, IP67, IP69k1) Vibration resistanceTo EN 60 068-2-6: Wall mounting class 2 H-rail mounting class 1 Shock resistanceTo EN 60 068-2-27: Wall mounting class 2 H-rail mounting class 1 To EN 60 068-2-29: Wall mounting class 1 H-rail mounting class 1 ApprovalCE Temperature rangeOperating[°C]–5 … +50pg Storage[°C]–20 … +40 MaterialsInfo 204 Dimensions (LxWxD)[mm]Info 204 Weight[g]Info 204 1) To DIN 40 050 Part 9 (only up to 50 bar at 80°C; with sealed CP connection) Type 4 to NEMA 250 (hose-down test, test no. 5.7)
2004/11 – Subject to change – Info 20127 Fieldbus Direct, CDVI-DN Technical data – Fieldbus node CDVI-DN Connection and display components 4321 6 51Power supply (plug, M12) 2CP extension (M9) 3Fieldbus input (plug, M12) 4Fieldbus output (socket, M12) 5PS Power system Operating voltage of electronics PL Power load Load voltage of valves MNS Module/network status CP Compact Performance CP extension modules 6Status display of the solenoid coils Pin allocation for fieldbus interface (M12 socket) PinSignal-specific core colourSignalDesignation 1blankScreenConnection to housing 2red24 V DC bus24 V supply CAN interface 3black0Vbus0VCANinterface 4whiteCAN_HReceived/transmitted data high 5blueCAN_LReceived/transmitted data low Pin allocation for fieldbus interface (M12 plug) PinSignal-specific core colourSignalDesignation 1blankScreenConnection to housing 2red24 V DC bus24 V supply CAN interface 3black0Vbus0VCANinterface 4whiteCAN_HReceived/transmitted data high 5blueCAN_LReceived/transmitted data low
Info 201 – Subject to change – 2004/1128 Fieldbus Direct, CDVI-DN Accessories – Fieldbus node CDVI-DN Ordering data DesignationTy p ePart No. Power supply Micro Style M12 Power supply socket, for Micro Style connection, M12, 5-pin, straight socket (A-coded)FBSD-GD-9-5POL18 324 Bus connection Micro Style M12 Micro Style connection, M12, 5- pin, straight socket (A- coded)FBSD-GD-9-5POL18 324 Micro Style connection, M12, 5-pin, straight plug (A-coded)FBS-M12-5GS-PG917 538 Valve terminal connection Connecting cable with angled plug and angled socket0.5 mKVI-CP-1-WS-WD-0,5178 564ggpgg 1mKVI-CP-1-WS-WD-1.0191 892 2mKVI-CP-1-WS-WD-2163 139 3mKVI-CP-1-WS-WD-3.0191 893 5mKVI-CP-1-WS-WD-5163 138 Connecting cable with straight plug and angled socket5mKVI-CP-1-GS-WD-5163 137 8mKVI-CP-1-GS-WD-8163 136 Connecting cable with straight plug and straight socket2 m, for chain link trunkingKVI-CP-2-GS-GD-2170 234ggpgg 5 m, for chain link trunkingKVI-CP-2-GS-GD-5170 235 8 m, for chain link trunkingKVI-CP-2-GS-GD-8165 616 User documentation User documentation for CDVI-DNGermanP.BE-CDVI-DN-DE539 044 EnglishP.BE-CDVI-DN-EN539 045 ItalianP.BE-CDVI-DN-IT539 048 FrenchP.BE-CDVI-DN-FR539 047 SpanishP.BE-CDVI-DN-ES539 046 SwedishP.BE-CDVI-DN-SV539 049 Software CD-ROMValve terminal user documentation (PDF)P.CD-VALVE-T183 350 UtilitiesP.CD-VI-UTILITIES-2533 500
2004/11 – Subject to change – Info 20129 Fieldbus Direct, CPV-CO2 Technical data – Fieldbus node CPV-CO2 CPV fieldbus node for communication between a CPV valve terminal and a fieldbusmaster.Thefieldbusnodeis used for activation of a CPV valve terminal with 8 valve slices and 16 solenoid coils and for displaying the switching status via LED. TheCPV-…valvesareactivatedusing automatic current reduction, which resultsinlesspowerconsumption and heat emission. 16 digital inputs and 8 digital outputs or 16 solenoid coils can be connected via a serial CP string extension. TheCPVvalveterminalsupportsthe CANopen protocol as per the specifications: DS 301, V4.02 DS 401, V2.1 TheCPVfieldbusnodeisavailablein three sizes, with identical performance characteristics: CPV10 CPV14 CPV18 Application Bus connection Plug connector 2xM12 Screw terminals Sub-D fieldbus plugThebranchlinelengthdoesnotapply no matter what type of connection is used. Screw terminals 5-pin screw terminal strip For installations in protected environments (IP20) The bus connection is established via a5-pinrow. If the valve terminal is ordered with this bus connection, the 5-pin screw terminal strip will also be supplied. It is designed with double screw terminals for the incoming and the outgoing bus cable. This connection technology provides the function of a T-distributor. Plug connector 2xM12 Plug connector 2xM12 Installation with IP65 protectionThe bus connection is established via an M12 plug and socket. The bus connection fulfils the require- ment of a T-distributor, this means that the CPV valve terminal can be disconnected from the bus without interrupting the bus. Sub-D fieldbus plug 9- pin Sub- D plug Installation with IP65 protection The bus connection is established via a 9-pin Sub-D plug as per the CAN in Automation (CiA) specification DS102 with additional 24 V CAN transceiver supply (option as per DS102). The bus connector plug facilitates the connec- tion of an incoming and an outgoing bus cable. There are spring-loaded terminals for the four wires (CAN_L, CAN_H,24V,0V)oftheincomingand outgoing bus cable.
Info 201 – Subject to change – 2004/1130 Fieldbus Direct, CPV-CO2 Technical data – Fieldbus node CPV-CO2 Condition monitoring Condition monitoring supports the preventative maintenance of the func- tionchaininautomationsystems. Each valve is assigned a switching cycle counter that automaticallyregisters movements of the system components. Once a maximum number of activations is reached, a message issent to the controller via CANopen and maintenance can be started. In the same way condition monitoring supports the determination of theservice intervals for the function chain. All movements immediately after installation are registered. General technical data Ty p eCPV10-GE-CO2-8CPV14-GE-CO2-8CPV18-GE-CO2-8 Part No.525 876525 882525 884 CP string extensionYes 16 inputs and 8 outputs (or 16 valves) Fieldbus interfaceSub-D, 9-pin, socket (to DS102) Bus interface electrically isolated via optocoupler, 24 V DC supply CAN interface via bus Baud rates[kbps]125, 250, 500 and 1000 Set using DIL switch Addressing rangeNode ID 1 … 127 Set using DIL switch Product familyDigital I/O Communication profileDS 301, V4.02 Device profileDS 401, V2.1 Number of PDOs1Tx/Rx Number of SDOs1serverSDO Configuration supportEDS file and bitmaps Max. address volume, inputs[Byte]8 Max. address volume, outputs[Byte]8 Max. no. of solenoid coils2x16 Max. no. of outputs8 (1x16 solenoid coils omitted) Max. no. of inputs16 digital LED diagnostic displaysPSOperating voltage for electronics and load supplygpy MNSBus status (module/network status) Device-specific diagnosisVia emergency message and object 1001, 1002 and 1003 ParameterisationVia SDO Additional functionsCondition counter Operating voltageNominal value[V DC]24, reverse polarity protectedpgg Permissible range[V]20.4 … 26.4 Power failure buffering[ms]10 Current consumption[mA]Max. 200 + sensor supply Protection class to EN 60 529IP65 ApprovalCE, CiA certification Temperature rangeOperating[°C]–5 … +50pg Storage[°C]–20 … +70 MaterialsHousingDie-cast aluminium Plug capPolyamide, glass fibre (Ultramide) SealNitrile rubber, Neoprene DimensionsInfo 213 Valve terminal CPV WeightInfo 213 Technical data for valvesInfo 213