GE Cpv14di018 Manual
Have a look at the manual GE Cpv14di018 Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 45 GE manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
2004/11 – Subject to change – Info 20131 Fieldbus Direct, CPV-CO2 Technical data – Fieldbus node CPV-CO2 Connection and display components 1 5 2 3 4 61Fieldbus connection: –9-pinSub-Dplug 2Switch module (removable) 3Connection for voltage supply (4-pin M12 plug, operating voltage for electronics, load voltage for CP valves) 4LEDs: –Powerstatus(PS) – Module/network status (MNS) 5CP extension connection 6Switching status displays of CPV solenoid coils Pin allocation for CANopen interface (plug view) PinSignalDesignation 1n.c.Not connected 2CAN_LReceived/transmitted data low 3CAN_GND0 V CAN interface 4n.c.Not connected 5CAN_ShldOptional screened connection 6GNDGround 7CAN_HReceived/transmitted data high 8n.c.Not connected 9CAN_V+24 V supply CAN interface HousingScreenConnection to functional earth Pin allocation for M12 adapter PinSignalDesignation 1ScreenConnection to housing 2CAN_V+24 V supply CAN interface 3CAN_GND0 V CAN interface 4CAN_HReceived/transmitted data high 5CAN_LReceived/transmitted data low Pin allocation for Open Style adapter PinSignalDesignation 1CAN_GND0 V CAN interface 2CAN_LReceived/transmitted data low 3ScreenConnection to housing 4CAN_HReceived/transmitted data high 5CAN_V+24 V supply CAN interface
Info 201 – Subject to change – 2004/1132 Fieldbus Direct, CPV-CO2 Technical data – Fieldbus node CPV-CO2 Ordering data DesignationTy p ePart No. Power supply Power supply socket, straightFBSD-GD-718 497 FBSD-GD-918 495 Power supply socket, angledFBSD-WD-718 524 FBSD-WD-918 525 Bus connection Sub-D plug for CANopenFBS-Sub-9-BU-2x5POL-B532 219 Mounting screw for standard Sub- D (IP20)UNC 4-40/M3x5340 960 Bus connection 2xM12 M12 adapterFBA-2-M12-5POL525 632 Fieldbus socket, M12, 5- pin, straightFBSD-GD-9-5POL18 324 Plug, M12, 5-pin, straightFBS-M12-5GS-PG9175 380 Bus connection, 5-pin, screw terminal strip Open Style adapter for 5-pin terminal stripFBA-1-SL-5POL525 634 5- pin terminal stripFBSD-KL-2x5POL525 635 Valve terminal connection Connecting cable WS-WD0.5 mKVI-CP-1-WS-WD-0,5178 564g 1mKVI-CP-1-WS-WD-1.0191 892 2mKVI-CP-1-WS-WD-2163 139 3mKVI-CP-1-WS-WD-3.0191 893 5mKVI-CP-1-WS-WD-5163 138 Connecting cable GS-WD5mKVI-CP-1-GS-WD-5163 137 8mKVI-CP-1-GS-WD-8163 136 Connecting cable GS-GD2 m, for chain link trunkingKVI-CP-2-GS-GD-2170 234g 5 m, for chain link trunkingKVI-CP-2-GS-GD-5170 235 8 m, for chain link trunkingKVI-CP-2-GS-GD-8165 616
2004/11 – Subject to change – Info 20133 Fieldbus Direct, CPV-CO2 Accessories – Fieldbus node CPV-CO2 Ordering data DesignationTy p ePart No. User documentation User documentation for CPV Direct, CPV fieldbus nodeGermanP. B E - C P - C O 2 - D E526 009, CO 2EnglishP. B E - C P - C O 2 - E N526 010 SpanishP. B E - C P - C O 2 - E S526 011 FrenchP. B E - C P - C O 2 - F R526 012 ItalianP. B E - C P - C O 2 - I T526 013 SwedishP. B E - C P - C O 2 - S V526 014 Software CD-ROMValve terminal user documentation (PDF)P.CD-VALVE-T183 350 UtilitiesP.CD-VI-UTILITIES-2533 500
Info 201 – Subject to change – 2004/1134 Fieldbus Direct, CPV-CO2 Fieldbus Direct applications
2004/11 – Subject to change – Info 20135 Fieldbus Direct, CPV-SD Technical data – Fieldbus node CPV-SD CPV fieldbus node for communication between a CPV valve terminal and a Smart Distributed System master. The fieldbus node is used for activation of a CPV valve terminal with 8 valve slices and 16 solenoid coils and for displaying the switching status via LED. TheCPV-…valvesareactivatedusing automatic current reduction, which resultsinlesspowerconsumption and heat emission. The CPV fieldbus node supports the Smart Distributed System fieldbus protocol. TheCPVfieldbusnodeisavailablein three sizes, with identical performance characteristics: CPV10 CPV14 CPV18 Application Bus connection The bus connection is established via 4-pin M12 plugs with protection class IP65. The bus connection is typically established via a branch line.The pin allocation corresponds to the Smart Distributed System specification. The bus connection also includes the 24 V DC supply for the electronics. -U-Typ e to be di sco n t i n u ed Available until 2008
Info 201 – Subject to change – 2004/1136 Fieldbus Direct, CPV-SD Technical data – Fieldbus node CPV-SD General technical data Ty p eCPV10-GE-SD-8 Part No.192 097 CP string extensionNo Baud ratesAutomatic baud rate detection Fieldbus interfaceM12, 4-pin Addressing range1…126 Set using switch module Object type168 Ident. number113 Max. no. of solenoid coils16 Max. no. of outputs0 Max. no. of inputs0 LED diagnostic displaysOperational status displaygpy Valve status Device-specific diagnosis via SDSUndervoltage of valves Operating voltageNominal value[V DC]24, reverse polarity protectedpgg Permissible range[V]21.0 … 26.4 Residual ripple[Vss]4 Power failure buffering[ms]20 Current consumption[mA]100 Protection class to EN 60 529IP65 ApprovalCE Temperature rangeOperating[°C]–5 … +50pg Storage[°C]–20 … +70 MaterialsHousingDie-cast aluminium Plug capPolyamide, glass fibre (Ultramide) SealNitrile rubber, Neoprene DimensionsInfo 213 Valve terminal CPV WeightInfo 213 Technical data for valvesInfo 213 -U-Typ e to be di sco n t i n u ed Available until 2008
2004/11 – Subject to change – Info 20137 Fieldbus Direct, CPV-SD Technical data – Fieldbus node CPV-SD Connection and display components 1234 5 6 1Load voltage connection for CPV valves 2Diagnostic LED 3Fieldbus/operating voltage connection 4Switch cover 5CP extension connection 6Switching status displays of CPV solenoid coils Example of circuit 3 1 2 1Connecting cable to equipotential bonding 2The 24 V load supply to the valves can be disconnected separately. The voltage for the bus interface and internal logic is supplied via the fieldbus connection. 3Earth terminal on left- hand end plate -U-Typ e to be di sco n t i n u ed Available until 2008
Info 201 – Subject to change – 2004/1138 Fieldbus Direct, CPV-SD Technical data – Fieldbus node CPV-SD Pin allocation for fieldbus interface and internal RC resistance network PinSignal 1DC 24 V bus interface/logic supply 2GND/0 V bus interface/logic supply 3Data – (CAN_L) 4Data + (CAN_H) HousingEarthing with metal M12 socket Pin allocation for load voltage connection (valve terminal plug view) PinSignal 1n.c. (not connected) 224VDCloadvoltageforCPvalves 30 V load voltage for CP valves 4n.c. (not connected) Ordering data DesignationTy p ePart No. Power supply Power supply socket, straightFBSD-GD-718 497 FBSD-GD-918 495 Power supply socket, angledFBSD-WD-718 524 FBSD-WD-918 525 Bus connection M12 Fieldbus socket, M12, 5- pin, straightFBSD-GD-9-5POL18 324 User documentation UserdocumentationforCPVDirect,CPVfieldbusnode SDGermanP. B E - C P - S D 8 - D E192 205 SDEnglishP. B E - C P - S D 8 - E N192 206 Software CD-ROMValve terminal user documentation (PDF)P.CD-VALVE-T183 350 UtilitiesP.CD-VI-UTILITIES-2533 500 -U-Typ e to be di sco n t i n u ed Available until 2008
2004/11 – Subject to change – Info 20139 Fieldbus Direct, CPV-IB Technical data – Fieldbus node CPV-IB CPV fieldbus node for communication between a CPV valve terminal and an Interbus master. The fieldbus node is used for activation of a CPV valve terminal with 8 valve slices and 16 solenoid coils and for displaying the switching status via LED. TheCPV-…valvesareactivatedusing automatic current reduction, which resultsinlesspowerconsumption and heat emission. 16 digital inputs and 8 digital outputs or 16 solenoid coils can be connected via a serial CP string extension. The CPV fieldbus node IB supports the Interbus fieldbus protocol and represents a remote bus station. TheCPVfieldbusnodeisavailablein three sizes, with identical performance characteristics: CPV10 CPV14 CPV18 Application Bus connection Sub-D plug Interbus outgoing Sub-D socket Interbus incomingThe bus connection is established via a 9- pin Sub- D socket and a 9- pin Sub-D plug with a typical Interbus pin allocation. The bus connector plugs (with protec- tion class IP65 from Festo or IP20 from other manufacturers) facilitate the connection of the incoming and the outgoing bus cable. The outgoing bus plug contains the typical Interbus RBST bridge for identification of the outgoing bus connection.The Sub-D interfaces are designed for the control of network components using a fibre optic cable connection.
Info 201 – Subject to change – 2004/1140 Fieldbus Direct, CPV-IB Technical data – Fieldbus node CPV-IB General technical data Ty p eCPV10-GE-IB-8CPV14-GE-IB-8CPV18-GE-IB-8 Part No.197 177197 179197 181 CP string extensionYes 16 inputs and 16 outputs Fieldbus interfaceSub- D, 9- pin, socket and pin Baud rates[kbps]500, 2000 Set using DIL switch Bus typeRemote bus Profile12 (digital I/O devices) PCP channelNo Configuration supportIcons for CMD software Max. no. of solenoid coils2x16 Max. no. of outputs8 (1x16 solenoid coils omitted) Max. no. of inputs16 Max. no. of process data bitsInputs32p Outputs32 LED diagnostic displaysULOperating voltage of Interbus interfacegpy RCRemotebus check BABus active RDRemotebus disable PowOperating voltage for electronics and load supply DiaShort circuit/overload of outputs Undervoltage of valves Undervoltage of outputs Undervoltage of sensor supply Missing module on CP string extension Actual/desired configuration not consistent Device-specific diagnosisVia peripherals errors ParameterisationNo Additional functionsDiagnosis using status bits (inputs) Operating voltageNominal value[V DC]24, reverse polarity protectedpgg Permissible range[V]20.4 … 26.4 Residual ripple[Vss]4 Power failure buffering[ms]10 Current consumption[mA]Max. 200 + sensor supply Protection class to EN 60 529IP65 ApprovalCE, Interbus Club certification Temperature rangeOperating[°C]–5 … +50pg Storage[°C]–20 … +70 MaterialsHousingDie-cast aluminium Plug capPolyamide, glass fibre (Ultramide) SealNitrile rubber, Neoprene DimensionsInfo 213 Valve terminal CPV WeightInfo 213 Valve terminal CPV Technical data for valvesInfo 213 Valve terminal CPV