Fieldbus Direct Extremely compact and space-saving Info 201 The ideal fieldbus solution for confined fitting spaces.
Info 201 – Subject to change – 2004/112 Convincingly direct: the overall concept A world class product with an impres- sive size to flow ratio. The Fieldbus Direct valve terminals CPV, CPV-SC andCPA-SCcanbeinstalledright where they’re needed, for example on a robot arm. Direct proximity to the actuator ensures short switching times. The CDVI with Fieldbus Direct offers an impressive corrosion- resistant and easy- to- clean surface. Convincingly direct: the electrical concept The first task involved in designing a system is the control concept. The fieldbussystemisextremelywellde- fined. Looking for the right pneumatic control concept? No problem with the CPV, CPV- SC, CPA- SC and the CDVI valve terminal from Festo. Direct actuation makes it compatible with all of the most commonly used fieldbus protocols: Profibus DP, Interbus, DeviceNet, CANopen, AS-interface ®, Beckhoff, ABB – including Festo plug & work ®. Convincingly direct: the pneumatic concept Valve terminals designed by the inven- tor of the valve terminal merely have to convince through the sum of their parts. With valve functions up to eight 5/2- way valves and up to sixteen 3/2- way valves and flow rates from 150 to 1,600 l/min, the modular, versatile, compact and sturdy Compact Performance terminals haveit all. Need vacuum technology? The CPV vacuum valve slice gives you vacuum technology right where it’s needed. An optional pneumatic multiple connector plate allows pneu- matic and electrical work to be carried out on the valve terminal at any time. The CDVI really comes into its own in corrosive environments. Fieldbus Direct: maximum performance in the minimum of space “Fieldbus Direct” valve terminals increase the productivity of decentralised system concepts. IP65 and direct fieldbus integration allows the Compact Performance valve terminal CPV, CPV-SC and CPA-SC to be installed closer to the actuator. They offer virtually unlimited flexibility thanks to versatile pneumatic connec- tion options. Fieldbus Direct is the most compact way of connecting valves to a fieldbus. Optional: the CP string extension The optional string extension allows additional valve terminals and I/O modules (16I, 16O) to be connected to the fieldbus nodes of the Fieldbus Direct valve terminals. A CP string of the CP installation system is inte- grated in the fieldbus node as an extension. The CP string extensions range from 0.5 to 10 metres in length, which means that the modules with selectable connection technology can be mounted directly on-site (IP65/IP67). Fieldbus Direct and valve terminals fromFesto–theflexiblespace- saving system
2004/11 – Subject to change – Info 2013 Fieldbus Direct – extremely compact and space-saving! Decentralised installation … decentralised networking … for small I/O units Drive-adjacent for short cycle times. Valve terminals directly at the fieldbus and expandable by max. 2 modules.Cost-effective solution for the connec- tion of a small number of input/ outputs at the fieldbus, incl. extension diagnostic options for each slave. Fieldbus Direct: one system for a number of tasks with an even greaternumberofadvantages. Advantages for designers Advantages for purchasers Advantages for commissioning and maintenance 1. Direct connection for fieldbus protocolsEasy integration in existing control systems Direct fieldbus connection of a small number of pneumatic drives Easy to switch between a number of fieldbus protocols (CPV)Reduced costs thanks to single sourcing Optimised product selection and warehousing Reliable ordering thanks to FACE software configurator with plausibility checkEasy to expand Fast and reliable switching of modules Extensive diagnostic options Condition monitoring 2. Proven basic pneumatic conceptReduced installation space thanks to maximum performance in confines spaces Terminal installed directly where it’s needed Flexible adaptation to the automation task Installation-saving solutions save timePneumatically innovative and proven technology reduces follow-up costs Reduced warehousing costs High reliability of supply Fully pre-assembled and tested units Low operating costsReduced costs thanks to fewer different parts Simple, step-by-step installation and commissioning 3. Access to a proven basic productComprehensive technical documentation for designers (parts list, dimensional drawings, etc.) Greater operational reliability and longer service lifeHigh machine availability High productivity Simple logisticsEasy advance commissioning Competent support and comprehensive product documentation Integrated diagnostic concept reduces system downtimes
Info 201 – Subject to change – 2004/114 Fieldbus Direct Key features The system Extremely compact and space- saving design Low- cost solution for the connection of a small number of valves to a fieldbus Extremely safe, degree of protection to IP69k depending on the series The Fieldbus Direct system contains four valve terminal series. CPV (type 10) CPVSC1 (type 80) CPASC1 (type 82) CDVI (type 15)The Fieldbus Direct product range is the most compact way of connecting valves to a fieldbus. The fieldbus node is directly integrated in the electrical interface of the valve terminal and therefore takes up only a minimal amount of space. Fieldbus Direct is a system for the connection of one valve terminal to nine different fieldbus standards. The most important systems includ- ing Profibus, Interbus, DeviceNet and CANopen are supported.The CP string extension option allows the functions and components of the CP installation system to be used. The optional string extension allows an additional valve terminal and I/O modules to be connected to the Fieldbus Direct fieldbus node. The I/O modules and cables for the CP string extension are ordered using the order code for the CP installation system.The max. length of the CP string extension is 10 metres, which means that the extension modules can be mounted directly on-site. All of the required electrical signals are trans- mitted via the CP cable, which in turn means that no further installation is needed on the extension module.
2004/11 – Subject to change – Info 2015 Fieldbus Direct Key features Switch module for CPV Direct The bus parameters and the device configuration of CPV Direct are set using the removable switch module. The integrated DIL switches are alsoeasy to set and check, even if the mounting position is difficult to access. CP string extension The optional string extension allows an additional valve terminal and I/O modules to be connected to the Fieldbus Direct fieldbus nodes. A CP string of the CP installation system is integrated in the fieldbus node as an extension. Different input and output modulesaswellasCPVandCPAvalve terminals can be connected.The max. length of the CP string extension is 10 metres, which means that the extension modules can be mounted directly on-site. All of the required electrical signals are trans- mitted via the CP cable, which in turn means that no further installation is needed on the extension module.The CP string interface offers: 16 input signals 16 output signals for output modules 24 V DC or solenoid coils Logic and sensor supply for the output modules Load voltage supply for the valve terminals Logic supply for the output module CPV Direct with fieldbus node Fieldbus8valveslices 16 solenoid coils 16 valves with 3/2- way valves CPV Direct with input module 24 V DC for detecting the cylinder end positions Fieldbus8valveslices 16 inputs M8 or M12, each with sensor supply
Info 201 – Subject to change – 2004/116 Fieldbus Direct Overview of examples Connection options FieldbusCPASC1 valve terminals with fieldbus interfaces can be equipped with 4 to 24 valve positions and 4 to 32 solenoid coils. Variants DeviceNet connection 4 to 32 solenoid coils FieldbusCPVSC1 valve terminals with fieldbus interfaces can be equipped with 4 to 16 valve positions and 4 to 16 solenoid coils. Variants DeviceNet connection 4 to 16 solenoid coils In Out 1 3 5 70 2 4 6 FieldbusCDVI-DN valve terminals with fieldbus interfaces can be equipped with 4, 6, 8or12valvepositionsand4to24 solenoid coils. Variants DeviceNet connection 4 to 24 solenoid coils Valve terminals for extension CPA valve terminal Max. 16 valves Size 10, 14Further information Info 214 Valve terminal CPA CPV valve terminal Max. 16 valves in 8 valve slices Size 10, 14, 18Further information Info 213 Valve terminal CPV
2004/11 – Subject to change – Info 2017 Fieldbus Direct Peripherals overview CP installation system input/output modules CP-E16-M12x2-5POL CP-E16N-M12x2-5POL16 inputs 24 V DC Signal status display via 16 LEDs Operating status displayM12 plug, double allocation 1x M9 CP connection PNP/NPN, IP65 CP-E16-M8 CP-E16N-M816 inputs 24 V DC Signal status display via 16 LEDs Operating status displayM8 plug, single allocation 1x M9 CP connection PNP/NPN, IP65 CP-E16-M8-Z16 inputs 24 V DC Signal status display via 16 LEDs Operating status displayElectrical isolation through additional power supply M8 plug, single allocation 1x M9 CP connection Separate sensor supply PNP/NPN, IP65 CP-E16-KL-IP20-Z2x8inputs24VDC Signal status display via 16 LEDs Operating status displayScrew terminal or tension- spring sockets 1x M9 CP connection Separate sensor supply PNP/NPN, IP20 CP-A08-M12-5POL CP-A08N-M128outputs24VDC Output signal display via 8 LEDs Operating status display M12 plug, single allocation2x M9 CP connection Separate load voltage Outputs resistant to overloads and short circuits PNP/NPN, IP65 Detailed description of input and output modules Info 221 CP installation system
Info 201 – Subject to change – 2004/118 Fieldbus Direct Peripherals overview CP Compact Line input/output modules In Out 1 3 5 7 CP-E08-M12x2-CL8 inputs 24 V DC Signal status display via 8 LEDs Operating status display4x M12 plug, 5-pin, double allocation 2x M9 CP connection PNP, IP65/67 In Out 1 3 5 70 2 4 6CP-E08-M8-CL8 inputs 24 V DC Signal status display via 8 LEDs Operating status display8xM8plug,3-pin,singleallocation 2x M9 CP connection PNP, IP65/67 CP-E16-KL-CL16 inputs 24 V DC Indirect signal status display via LEDs in the connection set of the tension-spring socket Operating status displayScrew terminal or tension- spring sockets 2x M9 CP connection PNP, IP20 CP-A04-M12x2-CL4outputs24VDC Signal status display via 4 LEDs Operating status display4x M12 plug, 5-pin, double allocation 2x M9 CP connection Outputs resistant to overloads and short circuits PNP, IP65/67 Detailed description of input and output modules Info 221 CP installation system CP connecting cable The CP string is connected using pre- assembled CP cables, which are sup- plied in lengths from 0.5 to 8 metres.
2004/11 – Subject to change – Info 2019 Fieldbus Direct, CPV-DI01 Technical data – Fieldbus node CPV-DI01 CPV fieldbus node for communication between a CPV valve terminal and a fieldbusmaster.Thefieldbusnodeis used for activation of a CPV valve terminal with 8 valve slices and 16 solenoid coils and for displaying the switching status via LED. The CPV-… valves are activated using automatic current reduction, which resultsinlesspowerconsumption and heat emission. 16 digital inputs and 8 digital outputs or 16 valves can be connected via a serial CP string extension. DI01 supports 4 different fieldbus protocols, which are selected by means of DIL switches: Profibus DP Moeller SUCOnet K ABB CS31 Festo fieldbus TheCPVfieldbusnodeisavailablein three sizes, with identical performance characteristics: CPV10 CPV14 CPV18 Application Bus connection M12 adapter Sub-D socket Sub-D socket 9- pin Sub- D socket Installation with IP65 protection The bus connection is established via a9-pinSub-Dsocketwithatypical Profibus allocation (to EN 50 170). The bus connector plug (with protec- tion class IP65 from Festo or IP20 from other manufacturers) facilitates the connection of an incoming and an outgoing bus cable. An active bus terminal can be connected using the integrated DIL switch. The Sub-D interface is designed for the control of network components with a fibre optic cable connection.M12 adapter Push-in connector 2xM12 Installation with IP65 protection Alternatively the bus connection can be established via a 2x M12 adapter plug (B-coded).
Info 201 – Subject to change – 2004/1110 Fieldbus Direct, CPV-DI01 Technical data – Fieldbus node CPV-DI01 General technical data Ty p eCPV10-GE-DI01-8CPV14-GE-DI01-8CPV18-GE-DI01-8 Part No.165 809165 811165 813 CP string extensionYes 16 inputs and 16 outputs Baud rates[kBaud]9.6 … 12,000; automatic detection Addressing rangeProfibus DP (12 MBaud) Festo fieldbus ABB CS31 Moeller SUCONET K1…125 Set using switch module Product family4: Valves Ident. number0xC9 Type of communicationCyclic communication Configuration supportGSD file and bitmaps Max. no. of solenoid coils2x16 Max. no. of outputs8 (1x16 solenoid coils omitted) Max. no. of inputs16 LED diagnostic displaysPOWEROperating voltage for electronics and load supplygpy BUSCommunication and configuration errors Device-specific diagnosis via PROFIBUS DPShort circuit/overload of outputs Undervoltage of valves Undervoltage of outputs Undervoltage of sensor supply Missing module on CP string extension Operating voltageNominal value[V DC]Reverse polarity protected Bus interface and logic, pin 1 Solenoid valve, pin 2 Permissible range[V]20.4 … 26.4 Current consumption[mA]Max. 100 Protection class to EN 60 529IP65 ApprovalCE Temperature rangeOperating[°C]–5 … +50pg Storage[°C]–20 … +70 MaterialsHousingDie-cast aluminium Plug capPolyamide, glass fibre (Ultramide) SealPerbunan, Neoprene DimensionsInfo 213 Valve terminal CPV WeightInfo 213 Technical data for valvesInfo 213