Home > GE > Alarm system > GE Cpv14di018 Manual

GE Cpv14di018 Manual

Here you can view all the pages of manual GE Cpv14di018 Manual. The GE manuals for Alarm system are available online for free. You can easily download all the documents as PDF.

Page 1

Fieldbus Direct
Extremely compact and space-saving
Info 201
The ideal fieldbus solution
for confined fitting spaces. 

Page 2

Info 201 – Subject to change – 2004/112
Convincingly direct: the overall
concept
A world class product with an impres-
sive size to flow ratio. The Fieldbus
Direct valve terminals CPV, CPV-SC
andCPA-SCcanbeinstalledright
where they’re needed, for example on
a robot arm. Direct proximity to the
actuator ensures short switching
times. The CDVI with Fieldbus Direct
offers an impressive corrosion-
resistant and easy- to- clean surface.
Convincingly direct: the electrical
concept
The first task involved in...

Page 3

2004/11 – Subject to change – Info 2013
Fieldbus Direct – extremely
compact and space-saving!
Decentralised installation … decentralised networking … for small I/O units
Drive-adjacent for short cycle times. Valve terminals directly at the fieldbus
and expandable by max. 2 modules.Cost-effective solution for the connec-
tion of a small number of input/
outputs at the fieldbus, incl.
extension diagnostic options for each
slave.
Fieldbus Direct: one system for a
number of tasks with an even...

Page 4

Info 201 – Subject to change – 2004/114
Fieldbus Direct
Key features
The system
Extremely compact and space-
saving design
Low- cost solution for the connection
of a small number of valves to a
fieldbus
Extremely safe, degree of protection
to IP69k depending on the series
The Fieldbus Direct system contains
four valve terminal series.
CPV (type 10)
CPVSC1 (type 80)
CPASC1 (type 82)
CDVI (type 15)The Fieldbus Direct product range is
the most compact way of connecting
valves to a fieldbus. The...

Page 5

2004/11 – Subject to change – Info 2015
Fieldbus Direct
Key features
Switch module for CPV Direct
The bus parameters and the device
configuration of CPV Direct are set
using the removable switch module.
The integrated DIL switches are alsoeasy to set and check, even if the
mounting position is difficult to
access.
CP string extension
The optional string extension allows
an additional valve terminal and I/O
modules to be connected to the
Fieldbus Direct fieldbus nodes. A CP
string of the CP installation...

Page 6

Info 201 – Subject to change – 2004/116
Fieldbus Direct
Overview of examples
Connection options
FieldbusCPASC1 valve terminals with fieldbus
interfaces can be equipped with 4
to 24 valve positions and 4 to
32 solenoid coils.
Variants
DeviceNet connection
4 to 32 solenoid coils
FieldbusCPVSC1 valve terminals with fieldbus
interfaces can be equipped with 4
to 16 valve positions and 4 to
16 solenoid coils.
Variants
DeviceNet connection
4 to 16 solenoid coils
In
Out
1
3
5
70
2
4
6
FieldbusCDVI-DN valve...

Page 7

2004/11 – Subject to change – Info 2017
Fieldbus Direct
Peripherals overview
CP installation system input/output modules
CP-E16-M12x2-5POL
CP-E16N-M12x2-5POL16 inputs 24 V DC
Signal status display via 16 LEDs
Operating status displayM12 plug, double allocation
1x M9 CP connection
PNP/NPN, IP65
CP-E16-M8
CP-E16N-M816 inputs 24 V DC
Signal status display via 16 LEDs
Operating status displayM8 plug, single allocation
1x M9 CP connection
PNP/NPN, IP65
CP-E16-M8-Z16 inputs 24 V DC
Signal status...

Page 8

Info 201 – Subject to change – 2004/118
Fieldbus Direct
Peripherals overview
CP Compact Line input/output modules
In
Out
1
3
5
7
CP-E08-M12x2-CL8 inputs 24 V DC
Signal status display via 8 LEDs
Operating status display4x M12 plug, 5-pin, double
allocation
2x M9 CP connection
PNP, IP65/67
In
Out
1
3
5
70
2
4
6CP-E08-M8-CL8 inputs 24 V DC
Signal status display via 8 LEDs
Operating status display8xM8plug,3-pin,singleallocation
2x M9 CP connection
PNP, IP65/67
CP-E16-KL-CL16 inputs 24 V DC...

Page 9

2004/11 – Subject to change – Info 2019
Fieldbus Direct, CPV-DI01
Technical data – Fieldbus node CPV-DI01
CPV fieldbus node for communication
between a CPV valve terminal and a
fieldbusmaster.Thefieldbusnodeis
used for activation of a CPV valve
terminal with 8 valve slices and
16 solenoid coils and for displaying
the switching status via LED. The
CPV-… valves are activated using
automatic current reduction, which
resultsinlesspowerconsumption
and heat emission. 16 digital inputs
and 8 digital outputs or...

Page 10

Info 201 – Subject to change – 2004/1110
Fieldbus Direct, CPV-DI01
Technical data – Fieldbus node CPV-DI01
General technical data
Ty p eCPV10-GE-DI01-8CPV14-GE-DI01-8CPV18-GE-DI01-8
Part No.165 809165 811165 813
CP string extensionYes
16 inputs and 16 outputs
Baud rates[kBaud]9.6 … 12,000;
automatic detection
Addressing rangeProfibus DP (12 MBaud)
Festo fieldbus
ABB CS31
Moeller SUCONET K1…125
Set using switch module
Product family4: Valves
Ident. number0xC9
Type of communicationCyclic communication...