AcuLaser M4000 Series Users Guide Replacing Consumable Products121 Chapter 5 Replacing Consumable Products Precautions During Replacement Always observe the following handling precautions when replacing consumable products. For details about the replacement, see the instructions on the package. ❏Provide enough space for the replacement procedure. You will have to open some parts (such as the printer cover) of the printer when you are replacing consumables. ❏Do not install used consumable products into the printer. w Warning: ❏Be careful not to touch the fuser, which is marked CAUTION HOT SURFACE or CAUTION HIGH TEMPERATURE, or the surrounding areas. If the printer has been in use, the fuser and surrounding areas may be very hot. ❏Do not dispose of used consumable products in fire, as they may explode and cause injury. Dispose of them according to local regulations. Replacement Messages If a consumable product reaches the end of its service life, the printer displays the following messages on the LCD panel or the window of EPSON Status Monitor. When this happens, replace the depleted consumable products. Note: Messages appear for one consumable product at a time. After replacing a consumable product, check the LCD panel for replacement messages for other consumable products. LCD Panel Message Description Replace Toner Cartridge The imaging cartridge has reached the end of its service life. Replace Fuser The fuser unit has reached the end of its service life.
AcuLaser M4000 Series Users Guide Replacing Consumable Products122 Imaging Cartridge Always observe the following handling precautions when replacing the consumable products: ❏Installing a genuine consumable product is recommended. Using a non-genuine consumable product may affect print quality. EPSON shall not be liable for any damages or problems arising from the use of consumable products not manufactured or approved by EPSON. ❏When handling imaging cartridge, always place it on a clean, smooth surface. ❏Do not install the consumable products that reach end of service life into the printer. ❏If you have moved an imaging cartridge from a cool to a warm environment, wait for at least one hour before installing it to prevent damage from condensation. ❏Do not open the drum’s protective cover and avoid exposing an imaging cartridge to room light any longer than necessary. Overexposing the cartridge may cause abnormally dark or light areas to appear on the printer page and reduce the life of the cartridge. w Warning: ❏Do not touch the toner. Keep the toner away from your eyes. If toner gets on your skin or clothes, wash it off with soap and water immediately. ❏Keep consumable products out of the reach of children. ❏Do not dispose of a used imaging cartridge in fire, as it may explode and cause injury. Dispose of it according to local regulations. ❏If toner is spilled, use a broom and dustpan or a damp cloth with soap and water to clean it up. Because the fine particles can cause a fire or explosion if they come into contact with a spark, do not use a vacuum cleaner.
AcuLaser M4000 Series Users Guide Replacing Consumable Products123 1. Open cover A slowly. Note: When the optional Stacker is installed, raise the Stacker first, then open cover A.
AcuLaser M4000 Series Users Guide Replacing Consumable Products124 2. Hold the handle of the imaging cartridge and pull out from the printer. 3. Take the new imaging cartridge out of its package and gently shake the imaging cartridge as shown below.
AcuLaser M4000 Series Users Guide Replacing Consumable Products125 4. Put the new imaging cartridge on the flat surface and pull out the protective yellow tape seal as shown below. 5. Insert the new imaging cartridge all the way until it stops. Note: Insert the cartridge with the arrow mark on the top of the imaging cartridge facing toward cover A.
AcuLaser M4000 Series Users Guide Replacing Consumable Products126 6. Close cover A until it clicks shut. Note: When the optional Stacker is installed, lower the Stacker after closing cover A. Fuser Unit Always observe the following handling precautions when replacing the consumable products: ❏Do not touch the surface of the consumable products. Doing so may impair print quality. w Warning: ❏The fuser unit can be very hot if the printer has been in use. Turn the printer off and wait for 30 minutes until the temperature has subsided before replacing the fuser unit. ❏Keep fuser units out of the reach of children.
AcuLaser M4000 Series Users Guide Replacing Consumable Products127 1. Turn off the printer and unplug the power cord and the interface cable. Note: If the printer has been in use, wait at least 30 minutes until the fuser cools down before replacing it. 2. Lift the cover B lever at the top left corner of the back of the printer.
AcuLaser M4000 Series Users Guide Replacing Consumable Products128 3. Open cover B. Note: If the Duplex Unit is installed, remove the unit before opening cover B. See “Removing the Duplex Unit” on page 101 for instructions. 4. Pull down the two levers at either side of the fuser unit.
AcuLaser M4000 Series Users Guide Replacing Consumable Products129 5. Remove the fuser unit slowly. Note: When removing the fuser unit, hold your hands as shown above, on the three tabs on both sides of the bottom of the fuser unit. 6. Push the tabs of the protective materials on both sides of the fuser unit, and remove the protective materials from the fuser unit.
AcuLaser M4000 Series Users Guide Replacing Consumable Products130 7. Slowly insert the new fuser unit. 8. Lift up the two levers at either side of the fuser unit to lock it. 9. Close cover B. 10. Reconnect the interface cable and power cord, and then turn on the printer.