Page 251

EPSON AcuLaser C9200NRevision D
DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 251
Confidential
Main Motor (M1)
1. Remove the Connector [1] and four Screws [2], and remove the Main Motor [3].
A5
B5
C5
[1]
[2]
[3]
4039F2C517DA
Transfer Drive Assy
1. Remove three Screws [1], and remove the Reinforcement plate [2] of the Right Door and 
spring [3].
	

Remove the spring with its tension loosened by declining right before the Left Door is 
closed.A6
B6
C6
[1]
[2] [3]
4038F2C118DA 

Page 252

EPSON AcuLaser C9200NRevision D
DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 252
Confidential2. Remove the Shoulder Screw [4].
3. Remove two Screws [5], and remove the Metal blanking plate [6].
[5]
[6]
[4]
4038F2C119DA
4. Remove two Screws [7] and remove the Rear Handle Assy Protect Cover [8].
5. Remove five Screws [9] and the Connector [10], and remove the Rear Handle Assy [11].
[9] [9] [10]
[11]
[9]
4038F2C121DA
[7]
[8] 

Page 253

EPSON AcuLaser C9200NRevision D
DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 253
Confidential6. Remove two Harnesses [12] from four Wire Saddles [11].
[10]
[11][11] [12]
[12]
4038F2C122DA
7. Remove eight Screws [13], and remove the Transport Drive Assy [14].
	

Screws [13] secure the Transfer Drive Assy are shown by △ mark.Never remove the Screws other than shown by △ mark.
[13][13] [14]
4038F2C123DA

	
 

Page 254

EPSON AcuLaser C9200NRevision D
DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 254
Confidential
Hopper Drive Assy
1. Disconnect seven Connectors [1].
A7
[1][1]
4038F2C124DB[1]
2. Remove the Harness from four Wire Saddles [2].
[2]
4038F2C125DA 

Page 255

EPSON AcuLaser C9200NRevision D
DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 255
Confidential3. Remove the Connector from the Cooling Fan Motor [3] and 1st Image Transfer Pressure/
Retraction Position Sensor [4].
4. Remove two Screws [5] and remove the Cooling Fan Motor [3] and Duct [6] 
simultaneously.
There is a possibility to install the wrong Connector because the Connector for the 
Cooling Fan Motor has a same number of Pins as the Connector for the 1st Image 
Transfer...

Page 256

EPSON AcuLaser C9200NRevision D
DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 256
Confidential
Standard Cassette Paper Feed Clutch (CL2)
1. Remove the E-ring [1], three Screws [2] and remove the Standard Cassette Feed Clutch 
Cover [3].
B7
[3][2] [1] [2]
2. Remove the E-ring[4] and three Screws [5] and then remove the Standard Cassette Feed Clutch 
Cover [6].3. Remove Upper conductive spring cover [9] by removing the screw [7] and Upper 
conductive spring [8].
[7]
[9][8]
[6] [4]
[5]
[5] 

Page 257

EPSON AcuLaser C9200NRevision D
DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 257
Confidential4. Remove the Conductive Spring Assy [11] by removing two Hooks [10].
	

The upper Hook of Conductive Spring Assy is disabled downside with tweezers.[11]
[10]
Before Releasing
After Releasing
[10] [11]

	

5. Remove three Screws [12] and two E-rings [13] and then remove the Drive Cover [14].
6. Remove the Feed Clutch [16] by removing the Connector [15].
[16]
[15]
[14]
[12] [12]...

Page 258

EPSON AcuLaser C9200NRevision D
DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 258
Confidential
Be cautious following things when installing the Feed Clutch.†
Let the Cable into the Notch.
†
Match the Rotation Stopper of the Clutch [17] with the Tab of the Main Unit [18] 
surely.
[18]
[17]
1st Image Transfer Pressure/Retraction Position Sensor 
(PC6)
1. Remove the 1st Image Transfer Pressure/Retraction Position Sensor Unit [3] by removing 
the Screw [1] and Connector [2].
C7
[3][1] [2] 

Page 259

EPSON AcuLaser C9200NRevision D
DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 259
Confidential
When removing the 1st Image Transfer Pressure/Retraction Position Sensor, if the 
Torsion Coil Spring has come off, correctly install it referring to the Figure. After 
installing the Torsion Coil Spring, check if the Actuator operates normally. 

Page 260

EPSON AcuLaser C9200NRevision D
DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 260
Confidential4.3.12  Group 12CONTENT
Parts/Units to be Disassembled
Guide
Right DoorNear Empty Assy
AB
Right Door
A
Near Empty Assy
B
 