Page 251
EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 251 Confidential Main Motor (M1) 1. Remove the Connector [1] and four Screws [2], and remove the Main Motor [3]. A5 B5 C5 [1] [2] [3] 4039F2C517DA Transfer Drive Assy 1. Remove three Screws [1], and remove the Reinforcement plate [2] of the Right Door and spring [3]. Remove the spring with its tension loosened by declining right before the Left Door is closed.A6 B6 C6 [1] [2] [3] 4038F2C118DA
Page 252
EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 252 Confidential2. Remove the Shoulder Screw [4]. 3. Remove two Screws [5], and remove the Metal blanking plate [6]. [5] [6] [4] 4038F2C119DA 4. Remove two Screws [7] and remove the Rear Handle Assy Protect Cover [8]. 5. Remove five Screws [9] and the Connector [10], and remove the Rear Handle Assy [11]. [9] [9] [10] [11] [9] 4038F2C121DA [7] [8]
Page 253
EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 253 Confidential6. Remove two Harnesses [12] from four Wire Saddles [11]. [10] [11][11] [12] [12] 4038F2C122DA 7. Remove eight Screws [13], and remove the Transport Drive Assy [14]. Screws [13] secure the Transfer Drive Assy are shown by △ mark.Never remove the Screws other than shown by △ mark. [13][13] [14] 4038F2C123DA
Page 254
EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 254 Confidential Hopper Drive Assy 1. Disconnect seven Connectors [1]. A7 [1][1] 4038F2C124DB[1] 2. Remove the Harness from four Wire Saddles [2]. [2] 4038F2C125DA
Page 255
EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 255 Confidential3. Remove the Connector from the Cooling Fan Motor [3] and 1st Image Transfer Pressure/ Retraction Position Sensor [4]. 4. Remove two Screws [5] and remove the Cooling Fan Motor [3] and Duct [6] simultaneously. There is a possibility to install the wrong Connector because the Connector for the Cooling Fan Motor has a same number of Pins as the Connector for the 1st Image Transfer...
Page 256
EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 256 Confidential Standard Cassette Paper Feed Clutch (CL2) 1. Remove the E-ring [1], three Screws [2] and remove the Standard Cassette Feed Clutch Cover [3]. B7 [3][2] [1] [2] 2. Remove the E-ring[4] and three Screws [5] and then remove the Standard Cassette Feed Clutch Cover [6].3. Remove Upper conductive spring cover [9] by removing the screw [7] and Upper conductive spring [8]. [7] [9][8] [6] [4] [5] [5]
Page 257
EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 257 Confidential4. Remove the Conductive Spring Assy [11] by removing two Hooks [10]. The upper Hook of Conductive Spring Assy is disabled downside with tweezers.[11] [10] Before Releasing After Releasing [10] [11] 5. Remove three Screws [12] and two E-rings [13] and then remove the Drive Cover [14]. 6. Remove the Feed Clutch [16] by removing the Connector [15]. [16] [15] [14] [12] [12]...
Page 258
EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 258 Confidential Be cautious following things when installing the Feed Clutch.† Let the Cable into the Notch. † Match the Rotation Stopper of the Clutch [17] with the Tab of the Main Unit [18] surely. [18] [17] 1st Image Transfer Pressure/Retraction Position Sensor (PC6) 1. Remove the 1st Image Transfer Pressure/Retraction Position Sensor Unit [3] by removing the Screw [1] and Connector [2]. C7 [3][1] [2]
Page 259
EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 259 Confidential When removing the 1st Image Transfer Pressure/Retraction Position Sensor, if the Torsion Coil Spring has come off, correctly install it referring to the Figure. After installing the Torsion Coil Spring, check if the Actuator operates normally.
Page 260
EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 260 Confidential4.3.12 Group 12CONTENT Parts/Units to be Disassembled Guide Right DoorNear Empty Assy AB Right Door A Near Empty Assy B