Epson Aculaser M 2000 Service Manual
Here you can view all the pages of manual Epson Aculaser M 2000 Service Manual. The Epson manuals for Printer are available online for free. You can easily download all the documents as PDF.
Page 201
EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 201 Confidential2. Remove two Connectors [2], the Type-B Guide rail [3], and three Harnesses [4]. 3. Remove nine Screws [5], and remove the Controller Board [6]. [2] [3] [4][4] [5] [5][5] [6] [5] Exit Tray 1. Open the Upper Fusing Cover [2]. 2. Remove two Claws [3], and remove the Upper Fusing Cover [2]. B3 C3 [2] [3] [3] 4039F2C019DA
Page 202
EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 202 Confidential3. Remove two Screws [5], and remove the Exit Sensor Holder [6]. 4. Remove three Screws [7], and remove the Exit Tray [8]. [5] [6] [7] [8] Controller Board Mounting Bracket 1. Remove three Wire Saddles [1], six Screws [6], and four Clamp Cores [3], then remove the Flat Cable Cover. B4 C4 [1] [2] [2] [4] [3]
Page 203
EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 203 Confidential2. Remove eleven Screws [5] and release the Edge Cover [6], and remove the Controller Board Mounting Bracket [7]. [5] [5] [5] [5] [7] [6] Mechanical Control Board (PWB-M) 1. Remove all the Connectors and Flat Cables on the Mechanical Control Board. 2. Remove six Screws [8] and remove the Mechanical Control Board [9]. B5 [8] [9] [8]
Page 204
EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 204 Confidential † When the Mechanical Control Board (PWB-M) is replaced, relocate the Parameter Chip (IC6). † Mount the Parameter Chip (IC6) of old Mechanical Control Board onto the new Mechanical Control Board. † When the Parameter Chip (IC6) is mounted, precisely fit the directions of each “A.” † When installing the Mechanical Control Board (PWB-M) , secure the Harness to the original location with the...
Page 205
EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 205 Confidential RTC Board (PWB-R) 1. Disconnect the Connector [1], and remove two Screws [2], and remove the RTC Board [3]. C5 [2] [3] [1] 4039F2C034DA
Page 206
EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 206 Confidential4.3.6 Group 6CONTENT DISASSEMBLY FLOWCHART Parts/Units to be Disassembled Guide Standard Paper CassettePaper Width Detection Unit AB A Standard Paper Cassette Paper Width Detection Unit B B1 A1 B2B3 Standard Paper Cassette (P. 207)Start Optional Cassette (P. 208) Paper Width Detection Unit (P. 209) *When the Optional Cassette is installed
Page 207
EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 207 Confidential Standard Paper Cassette 1. Slide out the Standard Paper Cassette [1]. A1 B1 [1] 2. Slide out the Standard Paper Cassette with pressing the Slide Locks [2] at both ends. [2][2]
Page 208
EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 208 Confidential Optional Cassette 1. Slide out the Optional Cassette [1]. B2 [1] 2. Remove the Screw [2] and remove the Stopper [3]. 3. Remove the Optional Cassette with while pressing the Slide Lock [4]. [3] [4] [2]
Page 209
EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 209 Confidential Paper Width Detection Unit 1. Remove the Paper Width Detection Unit pushing it toward the Right Door, with pushing the Knob [A] on the upper inside wall of the Tray toward the Right Door. B3 [1] [A] 2. Remove two Connectors and release the Harness from the tab of the Paper Width Detection Unit, then remove the Paper Width Detection Unit. † When the Paper Width Detection Unit has been removed,...
Page 210
EPSON AcuLaser C9200NRevision D DISASSEMBLY AND ASSEMBLY Main Unit Disassembly/Reassembly 210 Confidential4.3.7 Group 7CONTENT Parts/Units to be Disassembled Guide MP tray Left Cover + MP tray Right Cover + Tray ExtensionMulti Bypass UnitIDC Sensor/1 (SE1) + IDC Sensor/2 (SE2)Feed Roller (MP tray)Separation Roller (MP tray) ABCDE MP tray Right CoverA Tray Extension MP tray Left Cover A Multi Bypass Unit B A IDC Sensor/1 (SE1) IDC Sensor/2 (SE2) C C Feed Roller DE Separation Roller