Home > Epson > Printer > Epson Aculaser M 2000 Service Manual

Epson Aculaser M 2000 Service Manual

Here you can view all the pages of manual Epson Aculaser M 2000 Service Manual. The Epson manuals for Printer are available online for free. You can easily download all the documents as PDF.

Page 181

EPSON AcuLaser C9200NRevision D
DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 181
Confidential3. Remove two Screws [5], and remove the Exit Sensor Holder [6].
4. Remove three Screws [7], and remove the Exit Tray [8].
[5]
[6]
[7] [8]
Front Door
1. Open the Front Door.
2. Remove the Screw [1] each to remove the Right and Left Stoppers [2].
3. Pull out the Right and Left Pins [3] to remove the Front Door [4].
B7
C7
D7
[1] [4][2]
4038F2C038DB
[3]
4038F2C039DA 

Page 182

EPSON AcuLaser C9200NRevision D
DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 182
Confidential
Front Cover
1. Remove the Screw [1], and remove the Connector protective cover [2].
2. Disconnect two Connectors [3].
B8
C8
D8
[3]
4038F2C052DA
[1]
[2]
4038F2C051DA
3. Release two Hooks [4] and remove the Guide [5] installed in the insertion slot of the Toner 
Cartridge (K). 
Dont use too much force when releasing the Hooks of the Guide because they break 
easily.
[4]
[5] [4] 

Page 183

EPSON AcuLaser C9200NRevision D
DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 183
Confidential4. Disconnect two Connectors [6].
5. Remove four Screws [7].
[7]
[7][6]
4038F2C053DA
6. Remove six Claws [8] and remove the Front Cover [9].
[8]
[8][9]
4038F2C055DA 

Page 184

EPSON AcuLaser C9200NRevision D
DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 184
Confidential
Transfer Belt Unit

	

The Transfer Belt Unit is included in Transfer Kit as a service part. Additionally, the 
2nd Image Transfer Roller, Ozone filter, and Dust Filter are also included in Transfer 
Kit. Replace them at the same time. Refer to (Refer to Chapter 6 
“MAINTENANCE”) (p331))After the Transfer Belt Unit has been removed from the Main Unit for other purposes 
than...

Page 185

EPSON AcuLaser C9200NRevision D
DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 185
Confidential
†
Insert the Transfer Belt Unit into the Main Unit completely and make sure the 
Drive Gear of the Transfer Belt Unit matches with that of the Main Unit. And then, 
secure them with Screws. If they are secured even though both Drive Gears have 
not been matched, the Main Unit may be damaged when closing the cover. 
Matched Not Matched
PH Interface Board (PWB-D)
1. Pull out the Paper Cassette...

Page 186

EPSON AcuLaser C9200NRevision D
DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 186
Confidential3. Remove seven Screws [3], and remove the Right Door Switch Assy [4].
4. Remove four Screws [5] and remove four Photoconductor Unit Contact Assy [6] of each 
color.
[3][3]
[4]
4038F2C098DA
[5] [6]
4038F2C099DA
When connecting the Connector to the Photoconductor Unit Contact Assy, check the 
color of Connector and connect it to corresponding that of the Imaging Unit. 
YMCK 

Page 187

EPSON AcuLaser C9200NRevision D
DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 187
Confidential5. Remove eight Screws [7] and remove four Photoconductor Unit Roll Assy [8] of each color.
6. Remove all the Connectors and the Flat Cables on the PH Interface Board.
[7] [8]
4038F2C100DA
7. Remove two Screws [9] and six tabs [10], and remove the PH Interface Board [11].
[9][9]
[11] [10]
[10]
4038F2C102DB 

Page 188

EPSON AcuLaser C9200NRevision D
DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 188
Confidential
PH Unit
When replacing the PH Unit, replace four units at the same time.
Even when the single Unit needs to be replaced, replace four units.
1. Remove three Screws [1], three Connectors [2], and three Photoconductor Unit Guide rails 
[3].
D10
[1]
[2] [3]
4038F2C106DA
When installing the Photoconductor Unit Guide rail, insert its end correctly to the 
mounting hole in the Main Unit side. 

Page 189

EPSON AcuLaser C9200NRevision D
DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 189
Confidential2. Remove the Flat Cable [4] and the Connector [5] of the PH Unit (Black).
3. Remove the Claw [6] and remove the Gear [7] of the PH Unit (Black).
[7] [6]
4038F2C108DB
[4]
[5]
4038F2C107DA
When removing the Stopper, use care so that both ends of the Stopper will not open 
but stay parallel as shown in the figure above. Keep using the Stopper after once 
stretched out may cause uneven pitch or...

Page 190

EPSON AcuLaser C9200NRevision D
DISASSEMBLY AND ASSEMBLY      Main Unit Disassembly/Reassembly 190
Confidential5. Remove the PH Unit (Black) according to the following procedure.
1. Move the front side of the PH Unit to left a little, and remove the Boss [9] from the locating 
hole [10]. 
2. Lift up the front side of the PH Unit a little.
3. Remove the Boss [11] at the rear side of the PH Unit from the locating hole [12].
4. Remove the PH Unit [14].
6. Follow the same procedures to remove all PH...
Start reading Epson Aculaser M 2000 Service Manual

Related Manuals for Epson Aculaser M 2000 Service Manual

All Epson manuals