Epson Aculaser M 2000 Service Manual
Here you can view all the pages of manual Epson Aculaser M 2000 Service Manual. The Epson manuals for Printer are available online for free. You can easily download all the documents as PDF.
Page 141
EPSON AcuLaser C9200NRevision D Troubleshooting Image quality problem 141 Confidential LOW IMAGE DENSITY (DECREASE OF ID)A. Typical Faulty ImagesB. Troubleshooting ProcedureStep Section Check Item Result Action 1 Photoconductor Unit Dirty on the outside. YES Clean. 2 PH Unit The surface of the PH Window is dirty. YES Clean with cleaning jig. 3 TCR Sensor window The color TCR Sensor window on the LED Assy is dirty. YES Clean. 4 Transfer Belt Unit Transfer Belt makes positive contact with...
Page 142
EPSON AcuLaser C9200NRevision D Troubleshooting Image quality problem 142 Confidential GRADATION REPRODUCTION FAILUREA. Typical Faulty ImagesB. Troubleshooting Procedure FOGGY BACKGROUNDA. Typical Faulty ImagesB. Troubleshooting Procedure Step Section Check Item Result Action 1 Photoconductor Unit Dirty on the outside. YES Clean. 2 PH Unit The surface of the PH Window is dirty. YES Clean with cleaning jig. 3 TCR Sensor window TCR Sensor window is dirty. YES Clean. 4 Adjust Density Change the...
Page 143
EPSON AcuLaser C9200NRevision D Troubleshooting Image quality problem 143 Confidential VOID AREAS, WHITE SPOTSA. Typical Faulty ImagesB. Troubleshooting Procedure COLORED SPOTSA. Typical Faulty ImagesB. Troubleshooting Procedure Step Section Check Item Result Action 1 Image Check There are void areas at the front side or high density section. YES Refer to p.141. 2 There is void area at the rear side section. YES Change the setting value of TR XXX in the Printer Adjust Menu. 3...
Page 144
EPSON AcuLaser C9200NRevision D Troubleshooting Image quality problem 144 Confidential BLURRED IMAGEA. Typical Faulty ImagesB. Troubleshooting Procedure BLANK PRINT, BLACK PRINTA. Typical Faulty ImagesB. Troubleshooting Procedure Step Section Check Item Result Action 1 PH Unit The surface of the PH Window is dirty. YES Clean with cleaning jig. 2 Photoconductor Unit Dirty on the outside. YES Clean. 3 The problem has been eliminated through the checks of steps up to 2. NO Change...
Page 145
EPSON AcuLaser C9200NRevision D Troubleshooting Image quality problem 145 Confidential UNEVEN IMAGEA. Typical Faulty ImagesB. Troubleshooting ProcedureStep Section Check Item Result Action 1 Toner Cartridge The Toner Cartridge of every color is surely installed. NO Re-install it. 2 PH Unit PH Unit is surely installed. NO Re-install it. 3 Uneven pitch occurs in 3.0 mm pitch. YES Replace PH Unit Stopper. (p.175) 4 Toner Cartridge There is any stain or breakage on the Drive section of the Toner...
Page 146
EPSON AcuLaser C9200NRevision D Troubleshooting Image quality problem 146 Confidential WHITE LINES IN SUB SCAN DIRECTION, WHITE BANDS IN SUB SCAN DIRECTION, COLORED LINES IN SUB SCAN DIRECTION, AND COLORED BANDS IN SUB SCAN DIRECTIONA. Typical Faulty ImagesB. Troubleshooting ProcedureStep Section Check Item Result Action 1 Transfer Belt Unit Fingerprints, oil, or other foreign matter is evident on the Transfer Belt YES Clean with specified solvent. (Refer to Chapter 6 MAINTENANCE (p....
Page 147
EPSON AcuLaser C9200NRevision D Troubleshooting Image quality problem 147 Confidential WHITE LINES IN MAIN SCAN DIRECTION, WHITE BANDS IN MAIN SCAN DIRECTION, COLORED LINES IN MAIN SCAN DIRECTION, AND COLORED BANDS IN MAIN SCAN DIRECTIONA. Typical Faulty ImagesB. Troubleshooting ProcedureStep Section Check Item Result Action 1 Transfer Belt Unit Fingerprints, oil, or other foreign matter is evident on the Transfer Belt. YES Clean with specified solvent (Refer to Chapter 6 MAINTENANCE (p....
Page 148
EPSON AcuLaser C9200NRevision D Troubleshooting Image quality problem 148 Confidential UNEVEN DENSITY IN SUB SCAN DIRECTIONA. Typical Faulty ImagesB. Troubleshooting Procedure UNEVEN DENSITY IN MAIN SCAN DIRECTIONA. Typical Faulty ImagesB. Troubleshooting Procedure Step Section Check Item Result Action 1 Transfer Belt Unit Fingerprints, oil, or other foreign matter is evident on the Transfer Belt. YES Clean with specified solvent. (Refer to Chapter 6 MAINTENANCE (p. 331) ) 2 Transfer...
Page 149
EPSON AcuLaser C9200NRevision D Troubleshooting Image quality problem 149 Confidential LOW IMAGE DENSITY (DECREASE OF ID)A. Typical Faulty ImagesB. Troubleshooting ProcedureStep Section Check Item Result Action 1 Paper Paper is damp. YES Change paper to one just unwrapped from its package. Install Paper Dehumidifying Heater. 2 Transfer Belt Unit Terminal is dirty. YES Clean. 3 2nd Transfer Roller 2nd Transfer Roller is installed properly. NO Reinstall. 4 Charge Neutralizing Cloth is not...
Page 150
EPSON AcuLaser C9200NRevision D Troubleshooting Image quality problem 150 Confidential POOR COLOR REPRODUCTIONA. Typical Faulty ImagesB. Troubleshooting ProcedureStep Section Check Item Result Action 1 Paper Paper is damp. YES Change paper to one just unwrapped from its package. Install Paper Dehumidifying Heater. 2 Transfer Belt Unit Terminal is dirty. YES Clean. 3 2nd Transfer Roller 2nd Transfer Roller is installed properly. NO Reinstall. 4 Charge Neutralizing Cloth is not separated and...