Cleaning the Media Feed Rollers for Tray 2 (AcuLaser CX16NF only) Be sure to remove the duplex option before cleaning the media feed rollers for Tray 2. 1. If the duplex option is installed, remove it. Note: If the duplex option is not installed and the locking pins are installed at the back of Tray 2, remove the locking pins (one in each opening on the left and right sides at the back of Tray 2). To remove a locking pin, turn it to either the left or the right so that its grip is vertical, and then pull out the locking pin to remove it. 2. Remove the dust cover from Tray 1 and close the tray. 3. Lift the machine off of Tray 2 and temporarily place it on a sturdy flat surface. AcuLaser CX16 Series Printer / Copier / Scanner User’s Guide Maintenance 141
4. Clean the media feed rollers by wiping them with a soft, dry cloth. 5. Lift the machine and reinstall it on top of Tray 2. 6. Open Tray 1 and reattach the dust cover. 7. If you removed the duplex option in step 1, reinstall it. Note: If the duplex option is not to be installed, install the locking pins. While holding the grip of the locking pin vertical, insert the locking pin into the opening on either the left or right side of the 500-sheet paper cassette unit and, while pushing it in, turn it to either the left or the right. The locking pin is installed when its grip is horizontal. Installing the left and right locking pins secures the 500-sheet paper cassette unit to the machine so it cannot be removed. AcuLaser CX16 Series Printer / Copier / Scanner User’s Guide Maintenance 142
Cleaning the Media Feed Rollers for the attachment (AcuLaser CX16NF only) Be sure to remove the duplex option before cleaning the media feed rollers for the attachment. 1. If the duplex option is installed, remove it. 2. Remove the dust cover from Tray 1 and close the tray. 3. Lift the machine off of the attachment and temporarily place it on a sturdy flat surface. 4. Clean the media feed rollers by wiping them with a soft, dry cloth. AcuLaser CX16 Series Printer / Copier / Scanner User’s Guide Maintenance 143
5. Lift the machine and reinstall it on top of the attachment. 6. Open Tray 1 and reattach the dust cover. 7. If you removed the duplex option in step 1, reinstall it. Cleaning the Media Feed Rollers for the Duplex (AcuLaser CX16NF only) 1. Open the duplex door. AcuLaser CX16 Series Printer / Copier / Scanner User’s Guide Maintenance 144
2. Clean the feed rollers by wiping them with a soft, dry cloth. 3. Close the duplex door. Print Head Window Continuing to use this machine with a dirty print head window can cause print quality problems. Clearing the Print Head Window 1. With the main screen displayed, press the l key to display the PRINTER MODE screen. 2. Press the d key to select T/C CHANGE and then press the Select key. 3. Press the d key to select P/H CLEAN MODE and then press the Select key. AcuLaser CX16 Series Printer / Copier / Scanner User’s Guide Maintenance 145
Note: It is n o t po s si b le t o exi t P / H C LE A N MO DE before the operation is finished (even if the Stop/Reset key is pressed). If the machine has incorrectly been switched to P/H CLEAN MODE, perform steps 4 through 7, then steps 11 through 16 (skipping steps 8 through 10) to exit P/H CLEAN MODE mode. 4. Open the front cover. Note: Before opening the front cover, open Tray 1 if it is not already open. AcuLaser CX16 Series Printer / Copier / Scanner User’s Guide Maintenance 146
5. The magenta toner cartridge has been moved to the position from where it can be replaced. Pull down the handle on the toner cartridge until the toner cartridge is unlocked and moves out slightly toward you. Remove the toner cartridge. Note: When the magenta toner cartridge is removed, a gap is created within the machine so that the print head window can easily be cleaned. AcuLaser CX16 Series Printer / Copier / Scanner User’s Guide Maintenance 147
Note: Do not touch the contact indicated in the illustration. 6. Close the front cover. Note: The toner cartridge rotate within the machine. AcuLaser CX16 Series Printer / Copier / Scanner User’s Guide Maintenance 148
7. After the toner cartridges have finished rotating, open the scanner unit. Note: Do not touch the wires and flat cable shown in the illustration. AcuLaser CX16 Series Printer / Copier / Scanner User’s Guide Maintenance 149
8. Grab the handle and lift it up slightly to the back, and then slowly pull the photoconductor unit out vertically. Note: ❏Do not touch the PC drum and the transfer belt on the photoconductor unit. ❏Position the removed photoconductor unit horizontally as shown in the illustration below. Be sure to keep the photoconductor unit horizontal and place it where it will not become dirty. Do not leave the photoconductor unit removed for more than 15 minutes, and do not place the removed photoconductor unit in a location where it would be exposed to direct light (such as sunlight). AcuLaser CX16 Series Printer / Copier / Scanner User’s Guide Maintenance 150