Digital Projection E-Vision 8000 Series  INTRODUCTION Remote Communications Guide
55
Introduction
The projector can be controlled by using an external control system or a\
 PC via a LAN or RS232 serial interface, using a terminal-emulation 
program, such as HyperTerminal.
Operation commands
Operation commands simulate menu operations and determine the settings o\
f the projector, and use the following format:
• All commands consist of ASCII text strings starting with the letters ‘op’, and ending with\...

Page 62

Digital Projection E-Vision 8000 Series  THE OPERATION COMMANDS Remote Communications Guide
56
The Operation Commands
Notes
INPUT menu
input.sel= ?0 = HDMI
1 = DVI
2 = VGA
3 = Component / BNC
4 = Composite
5 = S-Video
6 = 3G-SDI
Not applicable when Picture Mute is On.
pip= ?0 = Off
1 = On
pip.sel= ?1 = HDMI
2 = DVI
3 = VGA
4 = Component / BNC
5 = Composite
6 = S-Video
7 = 3G-SDI
Cannot be set to 0.
pip.swap(execute)Swap main and PIP sourceNot applicable without signal locked.
pip.pos= ?0 = Top left
1 =...

Page 63

Digital Projection E-Vision 8000 Series  THE OPERATION COMMANDS Remote Communications Guide
57
...continued from previous page
Notes
pattern= ?0 = Color Bar
1 = Cross Hatch
2 = Burst
3 = Red
4 = Green
5 = Blue
6 = White
7 = Black
8 = Cross Mark
9 = Cross Hatch + Mark
10 = Red (TI)
11 = Green (TI)
12 = Blue (TI)
13 = HRamp (TI)
14 = Off
color.space= ?0  = Auto
1 = YCbCr
2 = YPbPr
3 = RGB-PC (0-255)
4 = RGB-Video (16-235)
Not applicable without signal locked.
input.lock= ?0  = Auto
1 = 48 Hz
2 = 50 Hz
3 =...

Page 64

Digital Projection E-Vision 8000 Series  THE OPERATION COMMANDS Remote Communications Guide
58
...continued from previous page
Notes
PICTURE menu
pic.mode= ?0 = High Bright
1 = Presentation
2 = Video
contrast= ? + -0 ~ 200Not applicable without signal locked.
dyna.cont= ?0 = Off
1 = On
Not applicable without signal locked.
bright= ? + -0 ~ 200Not applicable without signal locked.
saturat= ? + -0 ~ 200Not applicable without signal locked.
Only valid when the input is Composite or 
S-Video.
tint= ? + -0 ~...

Page 65

Digital Projection E-Vision 8000 Series  THE OPERATION COMMANDS Remote Communications Guide
59
...continued from previous page
Notes
blue.offset= ? + -0 ~ 200Not applicable without signal locked.
red.gain= ? + -0 ~ 200Not applicable without signal locked.
green.gain= ? + -0 ~ 200Not applicable without signal locked.
blue.gain= ? + -0 ~ 200Not applicable without signal locked.
sharpness= ? + -0 ~ 200Not applicable without signal locked.
nr= ? + -0 ~ 200Noise Reduction
Not applicable without signal...

Page 66

Digital Projection E-Vision 8000 Series  THE OPERATION COMMANDS Remote Communications Guide
60
...continued from previous page
Notes
LAMPS menu
lamps= ?0 = Single
1 = Dual
Not applicable when lamp is cooling.
lamp.mode= ?0 = Economy
1 = Standard
2 = Dimming
Drive
Not applicable without signal locked.
lamp.pwr= ?0 ~ 25 ( 80.4 % ~ 100.0 % )Not applicable without signal locked.
altitude= ?0 = Off
1 = On
High Altitude
lamp1.stat?0 = Off
1 = On
lamp2.stat?0 = Off
1 = On
ALIGNMENT menu
proj.mode= ?0 = Front
1...

Page 67

Digital Projection E-Vision 8000 Series  THE OPERATION COMMANDS Remote Communications Guide
61
...continued from previous page
Notes
h.keystone= ? + --350 ~ +350The sum of the absolute values of h.keystone and 
v.keystone cannot be greater than 350.
v.keystone= ? + --200 ~ +200The sum of the absolute values of h.keystone and 
v.keystone cannot be greater than 350.
warp.rotat= ? + --20 ~ +20Each unit is ¼°. 
warp.pinbrl= ? + --100 ~ +100Pincushion/Barrel
warp.tlc.x
warp.tlc.y
= ? + -x: -192 ~ +192
y: -120...

Page 68

Digital Projection E-Vision 8000 Series  THE OPERATION COMMANDS Remote Communications Guide
62
...continued from previous page
Notes
eb.blk.btm= ? + -0, 8, 16, 24, 32Black Level Uplift Area Bottom
eb.blk.left= ? + -0, 4, 8, 12, 16, 20, 24, 28, 32Black Level Uplift Area Left
eb.blk.right= ? + -0, 4, 8, 12, 16, 20, 24, 28, 32Black Level Uplift Area Right
eb.all= ? + -0 ~ 32Black Level Uplift Adjust Width All
eb.red= ? + -0 ~ 32Black Level Uplift Adjust Width Red
eb.green= ? + -0 ~ 32Black Level Uplift...

Page 69

Digital Projection E-Vision 8000 Series  THE OPERATION COMMANDS Remote Communications Guide
63
...continued from previous page
Notes
trig.1= ?0 = 5:4
1 = 4:3
2 = 16:10
3 = 16:9
4 = 1.88
5 = 2.35
6 = Letterbox
7 = Native
8 = Unscaled
9  = Auto
If trig.1 is set to Auto, the projector will start 
sending the trigger as soon as it is switched on. 
Otherwise the trigger will be sent only when the 
aspect ratio matches this setting.
auto.src= ?0 = Off 
1 = On
Auto Search
dblack= ?0 = Off
1 = On
Dynamic Black...

Page 70

Digital Projection E-Vision 8000 Series  THE OPERATION COMMANDS Remote Communications Guide
64
...continued from previous page
Notes
pip.src?0 = HDMI
1 = DVI
2 = VGA
3 = Component / BNC
4 = Composite
5 = S-Video
6 = 3G-SDI
PIP Source
pixel.clock?In MHz
Not applicable without signal locked.
signal?Not applicable without signal locked.
h.refresh?Not applicable without signal locked.
v.refresh?Not applicable without signal locked.
lamp1.hours?
lamp2.hours?
proj.runtime?
blue.only= ?0 = Off
1 = On...
Start reading Digital Projection Projector E-Vision 8000 Series User Manual

Related Manuals for Digital Projection Projector E-Vision 8000 Series User Manual

All Digital Projection manuals