Home > Digital Projection > Projector > Digital Projection Projector E-Vision 8000 Series User Manual

Digital Projection Projector E-Vision 8000 Series User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Digital Projection Projector E-Vision 8000 Series User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 577 Digital Projection manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Digital Projection E-Vision 8000 Series  INTRODUCTION Remote Communications Guide
    55
    Introduction
    The projector can be controlled by using an external control system or a\
     PC via a LAN or RS232 serial interface, using a terminal-emulation 
    program, such as HyperTerminal.
    Operation commands
    Operation commands simulate menu operations and determine the settings o\
    f the projector, and use the following format:
    • All commands consist of ASCII text strings starting with the letters ‘op’, and ending with\
     an ASCII Carriage Return character:
    op   [CR]
    • The  string can take one of the following formats:
    Description
    Set= Makes the setting take that value.
    Get?Asks what the current value is.
    The value is returned as an ASCII text string.
    Increment+Adds 1 to the current value.
    Decrement–Subtracts 1 from the current value.
    Execute(none)Performs an action.
    Examples
    op input.sel = 1 [CR] sets the input signal to DVI
    op input.sel ? [CR] asks what is the input signal
    op brightness + [CR] increments the brightness setting
    op contrast – [CR] decrements the contrast setting
    op auto.img [CR]   commands the projector to attempt to re-synchronise to the current input\
     source
    Key commands
    Key commands duplicate remote control key presses and use the following \
    format:
    ky [CR]
    Examples
    ky testpattern[CR] brings up the list of available test patterns (identical to pressing th\
    e TEST PATTERN key on the remote)
    ky input[CR]   brings up the list of available input sources (identical to pressing th\
    e INPUT key on the remote)
    ky power.off[CR]   switches the projector off (identical to pressing the POWER OFF key on the remote)
    Notes
     Details of how to connect to the 
    projector, using the serial control 
    or LAN inputs, can be found in the 
    Connections Guide.
     Spaces in the commands are 
    necessary.
      eg  op input.sel = 1 
    NOT opinput.sel=1
     The TCP Port number is 7000.
     The Serial Port settings are:
     ●Baud rate - 38,400 bps
     ●Data length - 8 bits
     ●Stop bits - one
     ●Parity - none
     ●Flow control - none 
    Rev F July 2014  
    						
    							Digital Projection E-Vision 8000 Series  THE OPERATION COMMANDS Remote Communications Guide
    56
    The Operation Commands
    Notes
    INPUT menu
    input.sel= ?0 = HDMI
    1 = DVI
    2 = VGA
    3 = Component / BNC
    4 = Composite
    5 = S-Video
    6 = 3G-SDI
    Not applicable when Picture Mute is On.
    pip= ?0 = Off
    1 = On
    pip.sel= ?1 = HDMI
    2 = DVI
    3 = VGA
    4 = Component / BNC
    5 = Composite
    6 = S-Video
    7 = 3G-SDI
    Cannot be set to 0.
    pip.swap(execute)Swap main and PIP sourceNot applicable without signal locked.
    pip.pos= ?0 = Top left
    1 = Top right
    2 = Bottom left
    3 = Bottom right
    4 = Split L-R
    Not applicable when PIP is Off.
    continued on next page...
    Notes 
    Rev F July 2014  
    						
    							Digital Projection E-Vision 8000 Series  THE OPERATION COMMANDS Remote Communications Guide
    57
    ...continued from previous page
    Notes
    pattern= ?0 = Color Bar
    1 = Cross Hatch
    2 = Burst
    3 = Red
    4 = Green
    5 = Blue
    6 = White
    7 = Black
    8 = Cross Mark
    9 = Cross Hatch + Mark
    10 = Red (TI)
    11 = Green (TI)
    12 = Blue (TI)
    13 = HRamp (TI)
    14 = Off
    color.space= ?0  = Auto
    1 = YCbCr
    2 = YPbPr
    3 = RGB-PC (0-255)
    4 = RGB-Video (16-235)
    Not applicable without signal locked.
    input.lock= ?0  = Auto
    1 = 48 Hz
    2 = 50 Hz
    3 = 60 Hz
    Not applicable without signal locked.
    no.signal= ?0 = Logo
    1 = Blue
    2 = Black
    3 = White
    vid.std= ?0  = Auto
    1 = PAL
    2 = SECAM
    3 = NTSC
    Not applicable without signal locked.
    Only valid when the input is Composite or 
    S-Video.
    auto.imgadj= ?0 = Off
    1  = Auto
    2  = Always
    Not applicable without signal locked.
    continued on next page...
    Notes 
    Rev F July 2014  
    						
    							Digital Projection E-Vision 8000 Series  THE OPERATION COMMANDS Remote Communications Guide
    58
    ...continued from previous page
    Notes
    PICTURE menu
    pic.mode= ?0 = High Bright
    1 = Presentation
    2 = Video
    contrast= ? + -0 ~ 200Not applicable without signal locked.
    dyna.cont= ?0 = Off
    1 = On
    Not applicable without signal locked.
    bright= ? + -0 ~ 200Not applicable without signal locked.
    saturat= ? + -0 ~ 200Not applicable without signal locked.
    Only valid when the input is Composite or 
    S-Video.
    tint= ? + -0 ~ 200Hue
    Not applicable without signal locked.
    Only valid when the input is Composite or 
    S-Video.
    gamma= ?0 = Film
    1 = Graphics
    2 = Video
    3 = Linear
    Not applicable without signal locked.
    color.temp
    (pic.mode is 
    “High Bright”)
    ?5 = NativeNot applicable without signal locked.
    Not applicable when Color Space is set to 
    Custom.
    Not applicable when edge blending is on.
    color.temp
    (pic.mode is 
    “Presentation”)
    = ?2 = 6500K
    5 = Native
    Not applicable without signal locked.
    Not applicable when Color Space is set to 
    Custom.
    Not applicable when edge blending is on.
    color.temp
    (pic.mode is 
    “Video”)
    = ?0 = 5000K
    2 = 6500K
    3 = 7800K
    4 = 9300K
    5 = Native
    Not applicable without signal locked.
    Not applicable when Color Space is set to 
    Custom.
    Not applicable when edge blending is on.
    red.offset= ? + -0 ~ 200Not applicable without signal locked.
    green.offset= ? + -0 ~ 200Not applicable without signal locked.
    continued on next page...
    Notes 
    Rev F July 2014  
    						
    							Digital Projection E-Vision 8000 Series  THE OPERATION COMMANDS Remote Communications Guide
    59
    ...continued from previous page
    Notes
    blue.offset= ? + -0 ~ 200Not applicable without signal locked.
    red.gain= ? + -0 ~ 200Not applicable without signal locked.
    green.gain= ? + -0 ~ 200Not applicable without signal locked.
    blue.gain= ? + -0 ~ 200Not applicable without signal locked.
    sharpness= ? + -0 ~ 200Not applicable without signal locked.
    nr= ? + -0 ~ 200Noise Reduction
    Not applicable without signal locked.
    aspect= ?0 = 5:4
    1 = 4:3
    2 = 16:10
    3 = 16:9
    4 = 1.88
    5 = 2.35
    6 = Letterbox
    7 = Native
    8 = Unscaled
    Not applicable without signal locked.
    Native aspect ratio is not applicable when zoom is 
    set to Zoom.
    zoom= ?0 = Off 
    1 = Crop 
    2 = Zoom
    Overscan
    Not applicable without signal locked.
    Zoom is not applicable when aspect ratio is set to 
    Native.
    h.total= ? + -0 ~ 200Not applicable without signal locked.
    Only applicable when the source is either VGA or 
    Component.
    h.pos= ? + -0 ~ 200Not applicable without signal locked.
    h.phase= ? + -0 ~ 200Not applicable without signal locked.
    Only applicable when the source is either VGA or 
    Component.
    v.pos= ? + -0 ~ 200Not applicable without signal locked.
    auto.img(execute)Auto Sync
    Not applicable without signal locked.
    continued on next page...
    Notes 
    Rev F July 2014  
    						
    							Digital Projection E-Vision 8000 Series  THE OPERATION COMMANDS Remote Communications Guide
    60
    ...continued from previous page
    Notes
    LAMPS menu
    lamps= ?0 = Single
    1 = Dual
    Not applicable when lamp is cooling.
    lamp.mode= ?0 = Economy
    1 = Standard
    2 = Dimming
    Drive
    Not applicable without signal locked.
    lamp.pwr= ?0 ~ 25 ( 80.4 % ~ 100.0 % )Not applicable without signal locked.
    altitude= ?0 = Off
    1 = On
    High Altitude
    lamp1.stat?0 = Off
    1 = On
    lamp2.stat?0 = Off
    1 = On
    ALIGNMENT menu
    proj.mode= ?0 = Front
    1 = Rear
    2 = Ceiling + Front
    3 = Ceiling + Rear
    fan.pos= ?0 = Normal
    1 = Vertical
    2 = Down
    zoomio+ -+ = Zoom out
    - = Zoom in
    focus+ -+ = Focus Near
    - = Focus Far
    vert.offset+ -+ = Up
    - = Down
    Vertical Lens Shift
    horiz.offset+ -+ = Right
    - = Left
    Horizontal Lens Shift
    lens.load=1 ~ 10Lens Memory Load
    lens.save=1 ~ 10Lens Memory Save
    lens.center(execute)
    continued on next page...
    Notes 
    Rev F July 2014  
    						
    							Digital Projection E-Vision 8000 Series  THE OPERATION COMMANDS Remote Communications Guide
    61
    ...continued from previous page
    Notes
    h.keystone= ? + --350 ~ +350The sum of the absolute values of h.keystone and 
    v.keystone cannot be greater than 350.
    v.keystone= ? + --200 ~ +200The sum of the absolute values of h.keystone and 
    v.keystone cannot be greater than 350.
    warp.rotat= ? + --20 ~ +20Each unit is ¼°. 
    warp.pinbrl= ? + --100 ~ +100Pincushion/Barrel
    warp.tlc.x
    warp.tlc.y
    = ? + -x: -192 ~ +192
    y: -120 ~ +120
    Top Left Corner
    warp.trc.x
    warp.trc.y
    = ? + -x: -192 ~ +192
    y: -120 ~ +120
    Top Right Corner
    warp.blc.x
    warp.blc.y
    = ? + -x: -192 ~ +192
    y: -120 ~ +120
    Bottom Left Corner
    warp.brc.x
    warp.brc.y
    = ? + -x: -192 ~ +192
    y: -120 ~ +120
    Bottom Right Corner
    warp.reset(execute)
    blank.top= ? + -0 ~ 360
    blank.btm= ? + -0 ~ 360
    blank.left= ? + -0 ~ 534
    blank.right= ? + -0 ~ 534
    blank.rst(execute)
    eb.stat= ?0 = Off
    1 = On
    Edge Blend
    eb.wht.top= ? + -0, 200 ~ 500Blend Width Top
    1-199 not allowed
    eb.wht.btm= ? + -0, 200 ~ 500Blend Width Bottom
    1-199 not allowed
    eb.wht.left= ? + -0, 200 ~ 800Blend Width Left
    1-199 not allowed
    eb.wht.right= ? + -0, 200 ~ 800Blend Width Right
    1-199 not allowed
    eb.blk.top= ? + -0, 8, 16, 24, 32Black Level Uplift Area Top
    continued on next page...
    Notes 
    Rev F July 2014  
    						
    							Digital Projection E-Vision 8000 Series  THE OPERATION COMMANDS Remote Communications Guide
    62
    ...continued from previous page
    Notes
    eb.blk.btm= ? + -0, 8, 16, 24, 32Black Level Uplift Area Bottom
    eb.blk.left= ? + -0, 4, 8, 12, 16, 20, 24, 28, 32Black Level Uplift Area Left
    eb.blk.right= ? + -0, 4, 8, 12, 16, 20, 24, 28, 32Black Level Uplift Area Right
    eb.all= ? + -0 ~ 32Black Level Uplift Adjust Width All
    eb.red= ? + -0 ~ 32Black Level Uplift Adjust Width Red
    eb.green= ? + -0 ~ 32Black Level Uplift Adjust Width Green
    eb.blue= ? + -0 ~ 32Black Level Uplift Adjust Width Blue
    eb.reset(execute)
    eb.adl= ?0 = Off
    1 = On
    Align Pattern
    CONTROL menu
    eco.net.pow= ?0 = Off (ECO Standby Mode)
    1 = On (Standard Standby Mode)
    Eco Network Power
    auto.powoff= ?0 = Off 
    1 = On
    auto.powon= ?0 = Off 
    1 = On
    proj.ctrl= ?0 = RS232
    1 = network
    Not applicable when Eco Network Power is on.
    net.ipaddr= ?
    net.subnet= ?
    net.gateway= ?
    net.dhcp= ?0 = Off
    1 = On
    startup.logo= ?0 = Off
    1 = On
    continued on next page...
    Notes 
    Rev F July 2014  
    						
    							Digital Projection E-Vision 8000 Series  THE OPERATION COMMANDS Remote Communications Guide
    63
    ...continued from previous page
    Notes
    trig.1= ?0 = 5:4
    1 = 4:3
    2 = 16:10
    3 = 16:9
    4 = 1.88
    5 = 2.35
    6 = Letterbox
    7 = Native
    8 = Unscaled
    9  = Auto
    If trig.1 is set to Auto, the projector will start 
    sending the trigger as soon as it is switched on. 
    Otherwise the trigger will be sent only when the 
    aspect ratio matches this setting.
    auto.src= ?0 = Off 
    1 = On
    Auto Search
    dblack= ?0 = Off
    1 = On
    Dynamic Black
    lang= ?0 = English
    1 = French
    2 = Spanish
    3 = German
    4 = Portuguese
    5 = Chinese Simplified
    6 = Chinese Traditional
    7 = Japanese
    8 = Korean
    SERVICE menu
    model?
    ser.no?
    sw.ver?
    act.src?0 = HDMI
    1 = DVI
    2 = VGA
    3 = Component / BNC
    4 = Composite
    5 = S-Video
    6 = 3G-SDI
    Active Source
    continued on next page...
    Notes 
    Rev F July 2014  
    						
    							Digital Projection E-Vision 8000 Series  THE OPERATION COMMANDS Remote Communications Guide
    64
    ...continued from previous page
    Notes
    pip.src?0 = HDMI
    1 = DVI
    2 = VGA
    3 = Component / BNC
    4 = Composite
    5 = S-Video
    6 = 3G-SDI
    PIP Source
    pixel.clock?In MHz
    Not applicable without signal locked.
    signal?Not applicable without signal locked.
    h.refresh?Not applicable without signal locked.
    v.refresh?Not applicable without signal locked.
    lamp1.hours?
    lamp2.hours?
    proj.runtime?
    blue.only= ?0 = Off
    1 = On
    fact.reset(execute)Factory reset
    Miscellaneous commands
    power.on(execute)Power on
    power.off(execute)Power off (puts projector into Standby mode)
    picture.mute= ?0 = Off
    1 = On
    status?0 = standby 
    1 = warm up 
    2 = imaging 
    3 = cooling 
    4 = warning
    remote.set= ?1 ~ 10: Set Projector ID
    255: Clear Projector ID (No ID)
    Notes 