Have a look at the manual Digital Projection Projector E-Vision 8000 Series User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 577 Digital Projection manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Digital Projection E-Vision 8000 Series INTRODUCTION Remote Communications Guide 55 Introduction The projector can be controlled by using an external control system or a\ PC via a LAN or RS232 serial interface, using a terminal-emulation program, such as HyperTerminal. Operation commands Operation commands simulate menu operations and determine the settings o\ f the projector, and use the following format: • All commands consist of ASCII text strings starting with the letters ‘op’, and ending with\ an ASCII Carriage Return character: op [CR] • The string can take one of the following formats: Description Set= Makes the setting take that value. Get?Asks what the current value is. The value is returned as an ASCII text string. Increment+Adds 1 to the current value. Decrement–Subtracts 1 from the current value. Execute(none)Performs an action. Examples op input.sel = 1 [CR] sets the input signal to DVI op input.sel ? [CR] asks what is the input signal op brightness + [CR] increments the brightness setting op contrast – [CR] decrements the contrast setting op auto.img [CR] commands the projector to attempt to re-synchronise to the current input\ source Key commands Key commands duplicate remote control key presses and use the following \ format: ky [CR] Examples ky testpattern[CR] brings up the list of available test patterns (identical to pressing th\ e TEST PATTERN key on the remote) ky input[CR] brings up the list of available input sources (identical to pressing th\ e INPUT key on the remote) ky power.off[CR] switches the projector off (identical to pressing the POWER OFF key on the remote) Notes Details of how to connect to the projector, using the serial control or LAN inputs, can be found in the Connections Guide. Spaces in the commands are necessary. eg op input.sel = 1 NOT opinput.sel=1 The TCP Port number is 7000. The Serial Port settings are: ●Baud rate - 38,400 bps ●Data length - 8 bits ●Stop bits - one ●Parity - none ●Flow control - none Rev F July 2014
Digital Projection E-Vision 8000 Series THE OPERATION COMMANDS Remote Communications Guide 56 The Operation Commands Notes INPUT menu input.sel= ?0 = HDMI 1 = DVI 2 = VGA 3 = Component / BNC 4 = Composite 5 = S-Video 6 = 3G-SDI Not applicable when Picture Mute is On. pip= ?0 = Off 1 = On pip.sel= ?1 = HDMI 2 = DVI 3 = VGA 4 = Component / BNC 5 = Composite 6 = S-Video 7 = 3G-SDI Cannot be set to 0. pip.swap(execute)Swap main and PIP sourceNot applicable without signal locked. pip.pos= ?0 = Top left 1 = Top right 2 = Bottom left 3 = Bottom right 4 = Split L-R Not applicable when PIP is Off. continued on next page... Notes Rev F July 2014
Digital Projection E-Vision 8000 Series THE OPERATION COMMANDS Remote Communications Guide 57 ...continued from previous page Notes pattern= ?0 = Color Bar 1 = Cross Hatch 2 = Burst 3 = Red 4 = Green 5 = Blue 6 = White 7 = Black 8 = Cross Mark 9 = Cross Hatch + Mark 10 = Red (TI) 11 = Green (TI) 12 = Blue (TI) 13 = HRamp (TI) 14 = Off color.space= ?0 = Auto 1 = YCbCr 2 = YPbPr 3 = RGB-PC (0-255) 4 = RGB-Video (16-235) Not applicable without signal locked. input.lock= ?0 = Auto 1 = 48 Hz 2 = 50 Hz 3 = 60 Hz Not applicable without signal locked. no.signal= ?0 = Logo 1 = Blue 2 = Black 3 = White vid.std= ?0 = Auto 1 = PAL 2 = SECAM 3 = NTSC Not applicable without signal locked. Only valid when the input is Composite or S-Video. auto.imgadj= ?0 = Off 1 = Auto 2 = Always Not applicable without signal locked. continued on next page... Notes Rev F July 2014
Digital Projection E-Vision 8000 Series THE OPERATION COMMANDS Remote Communications Guide 58 ...continued from previous page Notes PICTURE menu pic.mode= ?0 = High Bright 1 = Presentation 2 = Video contrast= ? + -0 ~ 200Not applicable without signal locked. dyna.cont= ?0 = Off 1 = On Not applicable without signal locked. bright= ? + -0 ~ 200Not applicable without signal locked. saturat= ? + -0 ~ 200Not applicable without signal locked. Only valid when the input is Composite or S-Video. tint= ? + -0 ~ 200Hue Not applicable without signal locked. Only valid when the input is Composite or S-Video. gamma= ?0 = Film 1 = Graphics 2 = Video 3 = Linear Not applicable without signal locked. color.temp (pic.mode is “High Bright”) ?5 = NativeNot applicable without signal locked. Not applicable when Color Space is set to Custom. Not applicable when edge blending is on. color.temp (pic.mode is “Presentation”) = ?2 = 6500K 5 = Native Not applicable without signal locked. Not applicable when Color Space is set to Custom. Not applicable when edge blending is on. color.temp (pic.mode is “Video”) = ?0 = 5000K 2 = 6500K 3 = 7800K 4 = 9300K 5 = Native Not applicable without signal locked. Not applicable when Color Space is set to Custom. Not applicable when edge blending is on. red.offset= ? + -0 ~ 200Not applicable without signal locked. green.offset= ? + -0 ~ 200Not applicable without signal locked. continued on next page... Notes Rev F July 2014
Digital Projection E-Vision 8000 Series THE OPERATION COMMANDS Remote Communications Guide 59 ...continued from previous page Notes blue.offset= ? + -0 ~ 200Not applicable without signal locked. red.gain= ? + -0 ~ 200Not applicable without signal locked. green.gain= ? + -0 ~ 200Not applicable without signal locked. blue.gain= ? + -0 ~ 200Not applicable without signal locked. sharpness= ? + -0 ~ 200Not applicable without signal locked. nr= ? + -0 ~ 200Noise Reduction Not applicable without signal locked. aspect= ?0 = 5:4 1 = 4:3 2 = 16:10 3 = 16:9 4 = 1.88 5 = 2.35 6 = Letterbox 7 = Native 8 = Unscaled Not applicable without signal locked. Native aspect ratio is not applicable when zoom is set to Zoom. zoom= ?0 = Off 1 = Crop 2 = Zoom Overscan Not applicable without signal locked. Zoom is not applicable when aspect ratio is set to Native. h.total= ? + -0 ~ 200Not applicable without signal locked. Only applicable when the source is either VGA or Component. h.pos= ? + -0 ~ 200Not applicable without signal locked. h.phase= ? + -0 ~ 200Not applicable without signal locked. Only applicable when the source is either VGA or Component. v.pos= ? + -0 ~ 200Not applicable without signal locked. auto.img(execute)Auto Sync Not applicable without signal locked. continued on next page... Notes Rev F July 2014
Digital Projection E-Vision 8000 Series THE OPERATION COMMANDS Remote Communications Guide 60 ...continued from previous page Notes LAMPS menu lamps= ?0 = Single 1 = Dual Not applicable when lamp is cooling. lamp.mode= ?0 = Economy 1 = Standard 2 = Dimming Drive Not applicable without signal locked. lamp.pwr= ?0 ~ 25 ( 80.4 % ~ 100.0 % )Not applicable without signal locked. altitude= ?0 = Off 1 = On High Altitude lamp1.stat?0 = Off 1 = On lamp2.stat?0 = Off 1 = On ALIGNMENT menu proj.mode= ?0 = Front 1 = Rear 2 = Ceiling + Front 3 = Ceiling + Rear fan.pos= ?0 = Normal 1 = Vertical 2 = Down zoomio+ -+ = Zoom out - = Zoom in focus+ -+ = Focus Near - = Focus Far vert.offset+ -+ = Up - = Down Vertical Lens Shift horiz.offset+ -+ = Right - = Left Horizontal Lens Shift lens.load=1 ~ 10Lens Memory Load lens.save=1 ~ 10Lens Memory Save lens.center(execute) continued on next page... Notes Rev F July 2014
Digital Projection E-Vision 8000 Series THE OPERATION COMMANDS Remote Communications Guide 61 ...continued from previous page Notes h.keystone= ? + --350 ~ +350The sum of the absolute values of h.keystone and v.keystone cannot be greater than 350. v.keystone= ? + --200 ~ +200The sum of the absolute values of h.keystone and v.keystone cannot be greater than 350. warp.rotat= ? + --20 ~ +20Each unit is ¼°. warp.pinbrl= ? + --100 ~ +100Pincushion/Barrel warp.tlc.x warp.tlc.y = ? + -x: -192 ~ +192 y: -120 ~ +120 Top Left Corner warp.trc.x warp.trc.y = ? + -x: -192 ~ +192 y: -120 ~ +120 Top Right Corner warp.blc.x warp.blc.y = ? + -x: -192 ~ +192 y: -120 ~ +120 Bottom Left Corner warp.brc.x warp.brc.y = ? + -x: -192 ~ +192 y: -120 ~ +120 Bottom Right Corner warp.reset(execute) blank.top= ? + -0 ~ 360 blank.btm= ? + -0 ~ 360 blank.left= ? + -0 ~ 534 blank.right= ? + -0 ~ 534 blank.rst(execute) eb.stat= ?0 = Off 1 = On Edge Blend eb.wht.top= ? + -0, 200 ~ 500Blend Width Top 1-199 not allowed eb.wht.btm= ? + -0, 200 ~ 500Blend Width Bottom 1-199 not allowed eb.wht.left= ? + -0, 200 ~ 800Blend Width Left 1-199 not allowed eb.wht.right= ? + -0, 200 ~ 800Blend Width Right 1-199 not allowed eb.blk.top= ? + -0, 8, 16, 24, 32Black Level Uplift Area Top continued on next page... Notes Rev F July 2014
Digital Projection E-Vision 8000 Series THE OPERATION COMMANDS Remote Communications Guide 62 ...continued from previous page Notes eb.blk.btm= ? + -0, 8, 16, 24, 32Black Level Uplift Area Bottom eb.blk.left= ? + -0, 4, 8, 12, 16, 20, 24, 28, 32Black Level Uplift Area Left eb.blk.right= ? + -0, 4, 8, 12, 16, 20, 24, 28, 32Black Level Uplift Area Right eb.all= ? + -0 ~ 32Black Level Uplift Adjust Width All eb.red= ? + -0 ~ 32Black Level Uplift Adjust Width Red eb.green= ? + -0 ~ 32Black Level Uplift Adjust Width Green eb.blue= ? + -0 ~ 32Black Level Uplift Adjust Width Blue eb.reset(execute) eb.adl= ?0 = Off 1 = On Align Pattern CONTROL menu eco.net.pow= ?0 = Off (ECO Standby Mode) 1 = On (Standard Standby Mode) Eco Network Power auto.powoff= ?0 = Off 1 = On auto.powon= ?0 = Off 1 = On proj.ctrl= ?0 = RS232 1 = network Not applicable when Eco Network Power is on. net.ipaddr= ? net.subnet= ? net.gateway= ? net.dhcp= ?0 = Off 1 = On startup.logo= ?0 = Off 1 = On continued on next page... Notes Rev F July 2014
Digital Projection E-Vision 8000 Series THE OPERATION COMMANDS Remote Communications Guide 63 ...continued from previous page Notes trig.1= ?0 = 5:4 1 = 4:3 2 = 16:10 3 = 16:9 4 = 1.88 5 = 2.35 6 = Letterbox 7 = Native 8 = Unscaled 9 = Auto If trig.1 is set to Auto, the projector will start sending the trigger as soon as it is switched on. Otherwise the trigger will be sent only when the aspect ratio matches this setting. auto.src= ?0 = Off 1 = On Auto Search dblack= ?0 = Off 1 = On Dynamic Black lang= ?0 = English 1 = French 2 = Spanish 3 = German 4 = Portuguese 5 = Chinese Simplified 6 = Chinese Traditional 7 = Japanese 8 = Korean SERVICE menu model? ser.no? sw.ver? act.src?0 = HDMI 1 = DVI 2 = VGA 3 = Component / BNC 4 = Composite 5 = S-Video 6 = 3G-SDI Active Source continued on next page... Notes Rev F July 2014
Digital Projection E-Vision 8000 Series THE OPERATION COMMANDS Remote Communications Guide 64 ...continued from previous page Notes pip.src?0 = HDMI 1 = DVI 2 = VGA 3 = Component / BNC 4 = Composite 5 = S-Video 6 = 3G-SDI PIP Source pixel.clock?In MHz Not applicable without signal locked. signal?Not applicable without signal locked. h.refresh?Not applicable without signal locked. v.refresh?Not applicable without signal locked. lamp1.hours? lamp2.hours? proj.runtime? blue.only= ?0 = Off 1 = On fact.reset(execute)Factory reset Miscellaneous commands power.on(execute)Power on power.off(execute)Power off (puts projector into Standby mode) picture.mute= ?0 = Off 1 = On status?0 = standby 1 = warm up 2 = imaging 3 = cooling 4 = warning remote.set= ?1 ~ 10: Set Projector ID 255: Clear Projector ID (No ID) Notes Rev F July 2014