Page 81
CONSOLE - PROGRAMMING OVERLAY l Cut out along border. l Cut out shaded openings. l Fit over console faceplate. 703500-567 PROORAMMING OVERLAY C70 C71 C72 C73 C74 C75 C76 C77 C78 C79 C60 C61 C62 C63 C64 C65 C66 C67 C68 C69 C50 C51 C52 C53 C54 C55 C56 C57 C58 C59 C40 C41 C42 C43 C44 C45 C46 C47 C48 C49 C30 C31 C32 C33 C34 C35 C36 C37 C38 C39 C20 C21 C22 C23 C24 C25 C26 C27 C28 C29 Cl0 CIIcl2 Cl3 Cl4 Cl5 Cl6 Cl7 Cl8 ‘Cl9
Page 82
IMI 66-060 CHAPTER 4 HAINTEBANCEMaintenance TECHNICAL ASSISTANCE AND REPAIR SERVICE Technical Assistance Should you experience zdifficulty with-installation, checkout, or programming,and have made an attempt to isolate the problem using information provided herein;or should you encounter problems at a later date which cannot be resolved by referring to this manual, call the Comdial Technical Service staff.They can be reached at l-800-366-8224 between the hours of 8:00 AM and 8:00 PM Eastern time, Monday...
Page 83
IMI 66-060 Maintenance ‘:7uvrA::250v SEWBLOW3ov 5V5v-5v l 5v -3ov COMM. BND. COMM. COMMA. I -3bvI II I7vhcSTATUS STATUS STATUS OUTbUT CONNECTORdVl abvSTATUS STATUSFigure 4-l.Fuse Location And Value and Power Supply Output ValuesFAILURE ISOLATION Wiring Refer to the installation check out procedure for instructions for testing the system wiring for possible failure.System Status Indicator The power supply contains five red LED indicators.When these LEDs are on,they indicate that their corresponding power...
Page 84
IMI 66-060Maintenance . Station Self Test The multiline stations can be self tested for proper operation per the following instructions. 1.Disconnect the line cord at the station base. IMPORTANT NOTE THE ADJACENT ODD OR EVEN STATION WILL BE DISABLED DURING THE TIME THAT THE STATION LINE CORD IS BEING DISCONNECTED OR RECONNECTED. 2.Press and hold theMUTEkey,and reconnect the.line cord to the station connector. The station will automatically perform a self test routine.Release theMUTE key as soon as the...
Page 85
IMI 66-060 MaintenanceIMPORTANT NOTE: The companion station will be disabled during the time that the console is being disconnected and reconnected. 3..Release console key ClO,and note that the BLF indicators will each turn on in sequence beginning with the station 10 indicator. Theindicators will then turn off and the console will become operational.Paired Stations Station ports 10 through 41 are paired for data and for overload protection as shown below.Console ports are not paired with any other...
Page 86
IMI 66-060 Maintenance If erratic light indications or ring signals occur at a paired station,an open data pair at either station may be the fault. A station with an open data line may work properly on a short loop but fail on along loop. Test the wiring of stations showing this symptom per the checkout procedure given in Chapter 2. If a fault occurs which.causes more than 300 ma. of current to be drawn,the overload paired stations are disabled by circuit action. Disconnect the disabled stations and...
Page 87
YESREPLACE FAILING TELEPHONE W’T%%WNTELEPHONEPERFORM SELF TESTFA:kDTELEPHONE L 1NO F” YES4 SERVICE AGENT REPLACE DEFECTIVE TELEPHONE I CONNECT TELCOlPBX INPUT FOR FAILED LINE TO UNUSED TELCO/PBX LINE PORT ON KSU (RggLygM ASSIGNMENT),HAVESERVICE AGENT REPLACE POWER SUPPLY )AND/OR KSU AND PERFORM COS d PROGRAMMING Figure 4-2.Failure Analysis Flow Chart
Page 88
IMI 66-060Maintenance DESK/WALL REVERSAL AND WALL MOUNTING (Executech II Multiline Telephone and Single-Line Keyset, Only) Conversion To convert a station from a standard desk model to one which can be hung on the wall, follow the procedure outlined below. 1.Remove and discard the pull out directory (Executech II Multiline Keyset, only). 2.Remove the lower housing of the station; and rotate it 180 degrees. CAUTION: The PWB contains circuitry which is sensitive to static electricity discharge.Be sure...
Page 90
IMI 66-060 GLOSSARY OF TERMSGlossary Of TermsAbandoned hold timeout: The length o.f time between when a distant party abandons a hold condition and when the line returns to an idle state is programmable.Access denied: Access to particular lines can be denied at certain stations by class of service.All-call and zone paging: Multiline station can receive voice announcements through the telephone speaker.Area paging: Dialing an access code or pressing dedicated line key can provide access to an external...