Home
>
Comdial
>
Communications System
>
Comdial Dxp Plus Digital Communications System Instructions Manual
Comdial Dxp Plus Digital Communications System Instructions Manual
Here you can view all the pages of manual Comdial Dxp Plus Digital Communications System Instructions Manual. The Comdial manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 11
1.4ReLoading Or Up-Grading The System Software The DXP Plus includes system software when it ships from the factory. At initial system installation,you do not need to load the system software to make the system operational. Should you need to later reload the system software (for software up-grade purposes for example), you can do so using the supplied system software disk. Use Windows File Manager or MS-DOS commands to save the disk’s information from your computer’s floppy drive to its hard drive....
Page 12
ItW66- 123DXP Plus Programming Instructions 1.5Using VMMI Software To Translate A DXP DatabaseYou can use the VMMI software to translate the database residing in a DXP to a format that is compatible with the DXP Plus, and load that database into the DXP Plus system. While translating data, your PC need not be connected to the DXP Plus.Before you translate a DXP database, determine the revision level of the DXP system software. If the DXP system software revision is 8.A or later, you can translate the...
Page 13
Saving the DXP Dafabase NOTE: This programming procedure details steps that one follows when using the communications software program known as PROCOMM (produced by Datastorm Technologies). If you are using a different communications software, your steps may be different. 1.Connect your PC to the DXP, and take the necessary steps to establish communications between the PC and the DXP. 2At the banner screen, type the password (default password is: 1%746+K). 3.Press CONTROL T for the main menu. 4.From the...
Page 14
/M/66-123DXP Plus Programming Instructions 1.5.2Translating The DXP Data Base 1. 2. 3. 4. 5. 6.Turn on your PC and load the Windows software. Select the VMMI program from the Windows menu screen. From the VMMI window, select the FILE pull-down menu. From the File pull-down menu, select Open. System default conditions cause the VMMI program to search for all *.DXP files in the VMMI directory; however, you may need to type the path location and DOS file name of the DXP database that you wish to...
Page 15
DXP Plus Programming instructions/M/66-123(c) The VMMI program presents a screen graphic that depicts the boards installed in a default arrangement in the main and expansion cabinets of a DXP Plus system. The default arrangement places station boards in ascending slot order beginning with slot 1 in the main cabinet; it places line boards in descending slot order beginning with slot 30 in the lower expansion cabinet. TheVMMI program leaves a blank slot for any place that you answered a station or line...
Page 16
1.6UsinVMMI Software To Archive Andiiestore The Data BaseYou can use the VMMI software to archive and restore the DXP Plus database. To archive and restore data, your PC must be connected to the DXP Plus (see Smtion 1.1).To archive a data base, 1. 2. 3. 4. 5. 6. 7. 8.Turn on your PC and load the Windows software. Select the VMMI program from the Windows menu screen. From the VMMI window, select the DXP pull-down menu. From the DXP pull-down menu, select Login.From the Login window, perform all login...
Page 17
DXP Plus Programming InstructionslMl66-123 1.7UsinVMMI Software To Perform Theiioard Configuration You can use the VMMI software to program the DXP Plus board configuration feature. To perform the board configuration feature, your PC must be connected to the DXP Plus (see Section 1.1). 1.Turn on your PC and load the Windows software. 2.Select the VMMI program from the Windows menu screen. 3.From the VMMI window, select the FILE pull-down menu. 4.From the File pull-down menu, select Open. 5.From the Open...
Page 18
lM166-123DXP PIUS Programming hstructions 1.6Configuring The Windows Terminal Emulation When configuring the terminal emulation program so that it can communicate with the DXP Plus, youmust arrange it to emulate either an ANSI standard, ANSI color, or WYSE 50 terminal Such emulations provide full screen editing of database information You must match the data configurations of the terminal emulation with those of the DXP Phs. The CPUboard provides a DIP switch that changes the DXP Plus data configuration...
Page 19
DXP Plus Programming InstructionslMi66-123 Reviewing General Programming Considerations Since the programming procedure is menu driven, you should consider all \ of the following points. lThe menu presents a list of selections for your consideration. Each sele\ ction differs in content and requires a different response. lWhen you respond to each selection, it either causes the system to prese\ nt a further breakdown of selections or causes a particular programming action to take place. lMenu lines prompt...
Page 20
3 Understanding Keyboard And Terminal Definrtions 3.1Reviewing The Keyboard Definitions The following list describes the functional keys on the keyboard. l Number keys:Use keys O-9 for selecting menu items, lines of data to edit, orfor editing numeric prompts. l Alphabetic keys: Use keys A-Z and a-z for entering string information such as names and messages. Always begin names of stations, lines, and so forth with a letter or a space. l ESCAPE key: This key will return you to the previous command prompt...