/M/66-123DXP Plus Programming Instructions
3.2Reviewing The Control Key DefinitionssThe following list describes the control key functions. Unless otherwise noted, control keys are valid
input at any time during programming.
0Control C (C for Cancel):l
Control E (E for Edit or Erase):
0Control I (I for Increment):l
Control N (N for Next):
0Control P (P for Previous):lControl R (R for Redraw):
0Control X (X for exit):
0Control S (S for Stop):l
Control T (T for Top):
0 Control V:This key will cancel the...

Page 22

DXP Plus Programming Instructions/M/66-123
Reviewing The Command
4
Prompts and Error Reporting
4.1Reviewing The Command PromptsThere are four different types of command prompts.
lMenu Selection Prompt: Use this prompt to make a menu selection. The system requires a numeric
input and displays the valid range of numbers in the prompt that corresponds to the number of menu
items displayed.
lEdit Line Prompt: Use this prompt on database editing screens to get to the desired line number tobe edited. The...

Page 23

Performing The Terminal
Emulation Programming
Once successfully entered, the programming mode causes your PC to display a welcoming menu. From the
welcoming menu, type I +k 7 4 6 % (note that you must type a Capital I ), and then press ENTER to display the
main programming menu.I9
////////////I/////// ////////I/////////
/////////I///
//////I ///I///////////////////////I//////////I /////I
/////////I
///////////I////// ////I////I///I//
/////II//////////////I///////////////...

Page 24

5. IReviewing The Programming Progression
Program the system in the sequence
shown in the following flow diagram.Determine system programmmg
parameters. Record them for future
reference.
From Windows, enter
terminal emulation modf
and use it to enter
DXP Plus programming
Perform MASTER CLEAR procedure.
(Initial installation procedure only!
Thls action
initializes system prior to programming and clears
all memory.)
Perform SYSTEM CLOCK
procedure*. (Sets time
displayed at LCD
speakerphones to current...

Page 25

DXP Plus Programming Instructions/M/66-123
Programming System Features
l Default Functional Programming.............6.1
l TerminalSetup......................6.2
l Messaging.........................6.3
l Serial Port (Serial Data Port Parameters)
.........6.4
lSubdued Off-Hook Voice Announce
(SOHVA) Programming..................6.5
l SpeedDial Programming.................6.6
l System Clock (Time and Date) ..............6.7
l SystemTiming.......................6.8
l System...

Page 26

lM166-123DXP Plus Programming Instructions
6. IDefault Functional Programming
6.1.1Master Clear
Description.=
Programming:
The master clear feature in an on-line procedure that returns the entire system to the default
operating parameters, clears 
all stored speed dial numbers, and clears any other custom
programming as well. The system takes 15 to 20 seconds to exercise a master clear command
depending upon the system size.
You can take one of three different master clear options.
With master clear mode...

Page 27

6.1.2System DefaultDescription:The system default sets the system configuration features to the default operating parameters.
When the system default is performed, certain programmed data, such as custom LCD messages
and system speed dial numbers, are lost.
Programming;1. Press CONTROL T for main menu.
2. From main menu, select system and press ENTER.
3. From system menu, select defaults and press ENTER.
4. From defaults menu, select system and press ENTER.
5. Type y to confirm default or n to deny....

Page 28

6.1.5Bufton Mar, Default
Description.=Every programmable button at each telephone connected to the system provides line selection,
direct station selection, or other functions. Programming action for a particular station assigns a
function to each button Unique button function assignment, known as button mapping, at each
station is possible. This default erases all unique button function assignments and clears all
speed dial locations.
Programming:1 e Press CONTROL T for main menu.
2. From main menu,...

Page 29

6.1.8DID Translation Table, DefaultDescription:
If you have programmed translation tables for DID use (Section 8.4.4), you can clear them with
this procedure.
Programming;1. Press CONTROL T for main menu.
2. From main menu, select system and press ENTER.
3. From system menu, select defaults and press ENTER.
4. From defaults menu, select DID translation table and press ENTER.
5. Type DID table number (1-S) and press ENTER.
6. Repeat step 5 until finished.
7. Press ESCAPE to end.
6.1.9Clear System Status...

Page 30

IMl66- 123DXP Plws Programming Instructions
6.1.11Software Reset
Description:You can reset the system software with this procedure. Resetting the software aligns the
memory pointers and clears any erronous data from the memory locations. Resetting the
software is a memory housekeeping routine and does not default the programmed parameters.
Do not reset the system software while the system is in use. The resetting action will
disconnect all in-progress calls.
Programming;1. Press CONTROL T for main menu....