Page 1

COMDlAL
DSU
Digital Telephone System
Video Display Terminal
Programming Manual
This publication is’applicable to the following common equipment base
units GO408 Rev. A and later, GO816 Rev. A and later, or G1632 Rev. A
and later; with software cartridges IO 408, SO408; 10816, SO816; or
101632, SO1632 Rev. 
14A and later. 

Page 2

contents
11.
-I
Table of Contents
Introducing VDT Programming1
1.1Using This Book 1
1.2Knowing The Programming Commands1
1.3Operating A PC 2
1.3.1Setting The Data Communication Parameters2
1.3.2Setting The Terminal Parameters 3
1.3.3prograrming The System and Loading / Saving The Data Base‘3
1.4Using The Password 4
1.5Master Clearing The System 4
2.Programmiug The System 5
2.1 Using This Chapter 5
2.2 Defaulting The System 6
2.2.1 Default All System Data 6
2.2.2Default All Line Data2.2.3 Default All...

Page 3

co?ltentsZMZ66-094
2.4System Timing 12
2.4.1Recall Tap Time12
2.4.2
Pause Time12
2.4.3Timed Hold Recall12
2.4.4Transfer Recall Time12
2.4.5
Department Transfer Recall Time13
2.4.6Call Park Recall Time13
2.4.7DTMF Extended Dialing13
2.5Load / Save C.O.S. Data14
2.5.1Transmit C.O.S. Data Using Xmodem14
2.5.2Receive C.O.S. Data Using Xmodem14
2.5.3Transmit Auto Dial and Speed Dial NumbersUsing Xmodem 15
2.5.4Receive Auto Dial and Speed Dial NumbersUsing Xmodem 15
2.6Serial Communication Parameters16...

Page 4

Contents
2.17Specialized Route Access 26
2.17.1Specialized Route Access Feature26
2.17.2Assign Line Group Number to Office Code26
2.17.3Assign Line Group Number to Area Code
26
2.17.4Assign Line Group Number to Special Table26
2.17.5Overflow Line Group 26
2.17.6Assign Area Code 27
2.17.7Clear Area Code 27
2.17.8Assign Insert Digit 27
2.17.9Clear Insert Digit 27
2.17.10SRA Wait Time
2.18Software Version Number 28
3.Programming The Lines29
3.1
3::
i:S
E
3:8
3.9
3.10
3.11
3.12
3.13
3.14Using This Chapter29...

Page 5

Conte?ltkZMZ6tSO944.7
4.7.1
4.7.2
4.7.3
4.7.44.8
4.9
4.10
4.11
4.12Ringing Assignments 36
Personal Ringing Tone36
Direct / Delayed Ri.n$ng36
Night Ringing
Distinctive Ringing for AT1
36Button Mapping 37
Toll Restriction Administration37
Automatic Busy / RNA Call Forwarding37
Miscellaneous Features Prograxn$ng38
Speakerphone Coeffkients
5.Toll Restriction Table Administration41Build 
/ Modify an Allow Table41
Build 
/ Modify a Deny Table41Clear a Table 
/ Entry41
Toll Restriction Programming Steps42...

Page 6

ZMZ66-094ZntroductionIntroducing VDT Programming
1.1Using This Book
This publication provides instruction for programming a digital telephone system, or Digital Service Unit (DSU),
using a Video Display Terminal 
(VDT).You can use a personal computer that is running a terminal emulation
software program as a VDT if desired (See pages 2 and 3).Refer to the Digital Telephone System Manual.
IMI66-107, section 4-77, for a detailed discussion about VDT connection and use.
We have preprogrammed the telephone...

Page 7

PCoperati5nIMA%-094
1.3Operating A Personal Computer
The following procedure is given as a typical example for using a PC and an XMODEM-type communications
software program to program the digital telephone system.It is only provided for illustration 
andzference purposes
and describes a set-up using a typical 
communications software program known as PROCOMM(produced by
Datastorm Technologies, Inc.).Many other communications software programs are also available that you can use
for this purpose. While...

Page 8

ZMZ66-094PC Operation
I.32Setting The Terminal Parameters
Jh?scription:The Terminal parameters are the matching parameters for the DSU. Remember, all of them must be the
same as they are for the DSU.NOTE:
Setting the terminal emulation for a Wyse-50 or VT-100 emulation will provide a compatible set of &fault
values; however, any 
emukztion which provides fill duplex operation is satisfactory.
ToProgram:1.Once in ?RQCOMMTM k.ss ALT S2. 
Press2andRETURN3. 
PresslandRETURN
4.Use arrow keys to select VDT-100...

Page 9

Programming Introduction
1.4Using the Password
ZMI66-094
To enter the programming mode, you must first enter the password Q*746*).
If you have not made a programming
choice within a set amount of time, approximately three minutes, the system will automatically logoff. If logoff
occurs, you must re-enter the password.
1.5Master Clearing the System
Before you begin any programming, you can master clear the system. Master clearing returns the entire system to
default conditions.
NOTE:Do not do this unless...

Page 10

IM66-094system C.O.S. RogmnImingProgramming The System
2.1Using This Chapter
Programming the customer’s new system is the most intricate and important aspect of the installer’s job. Chapter
Two deals only with the programming of the system, which means that you are setting the parameters 
char will be
truefor the entire sysrm.Jf you are unsure whether or not you are programming the correct function, check tbe
features chapter of 
JMI66-107 for a full definition of the features.You should make a record of...
Start reading Comdial Digital Telephone System Programming Manual

Related Manuals for Comdial Digital Telephone System Programming Manual

All Comdial manuals