     Provisioning 
     
    78-4025112-01 Rev H0 107 
     
    Note: Once a carrier is in data mode, Data Map becomes active for that carrier.  The 
    Data Map serves as a routing table which maps incoming data to unique output 
    carriers. 
    To Configure the Data Map 
    1 Navigate to the Maps page. 
    2 In the tree menu, select Data Map. 
     
    3 Configure the Stream Type to be MPEG for the desired carrier.  
    Note: The Stream Type setting of the RFGW-1-D is dependent upon the rf-
    channel configuration for the relevant controller modular-Cable in the CMTS. 
    The following table lists the valid Stream Type settings for each of the rf-channel 
    options in the uBR10K. 
    rf-channel (CMTS) Stream Type (RFGW-1-D) 
    udp-port MPEG 
    depi-remote-id DOCSIS MPT w/o UDP 
    In DOCSIS 2.0 Cisco Wideband operation, the eQAM device carries only 
    wideband channels (non-primary DOCSIS).  For non-primary flows in DOCSIS 
    2.0 Cisco Wideband operation, rf-channels are typically configured as udp-ports 
    in the CMTS, and the valid Stream Type is MPEG.  For DOCSIS 3.0 Cisco 
    Wideband operation, most operators are migrating to using depi-remote-id for 
    all rf-channels.  This is done primarily to provide flexibility in defining primary 
    and non-primary channels.  For flows defined as depi-remote-id in the CMTS, 
    the valid Stream Type is DOCSIS MPT w/o UDP.  
    						
    							 
    Chapter 6    Wideband Data Specific Operation  
     
     
    108 78-4025112-01 Rev H0 
    4 Select the Allowable Ingress Ports which receives the flows from the CMTS.  
    The correct GbE port (independent mode) or port-pair (port-pair mode) will 
    have its GbE port physical address (independent mode) or Video/Data IP 
    address (port-pair mode) under the System/IP Network web view configured to 
    match the eQAM IP address in the CMTS. 
    5 Enter the Destination UDP Port for the input stream to be mapped out to the 
    relevant RF Gateway 1 carrier.  The Destination UDP Port must match the udp-
    port of the corresponding rf-channel in the CMTS. 
    Notes:  
    – Session ID will automatically set to N/A when Stream Type is MPEG. 
    – For a given ingress port pair, the UDP port or session ID must be unique. 
    6 Click Apply. 
    7 Click Save. 
      
    						
    							 
     
     Status Monitoring 
     
    78-4025112-01 Rev H0 109 
     
    Status Monitoring 
    Introduction 
    This section provides information for status monitoring for video streams using the 
    RF Gateway 1 web page. 
    The RF Gateway 1 provides utilities for monitoring: 
     Input streams (i.e., stream type, status, IP, UDP, input bitrate) 
     Output streams (i.e., session ID, destination QAM channel)   
    Monitoring 
    To View Input Monitoring 
    1 Navigate to the Monitor page. 
    2 In the tree menu, select the Input/GbE port. 
    Result: Input monitoring is shown for each GbE port. 
      
    						
    							 
    Chapter 6    Wideband Data Specific Operation  
     
     
    110 78-4025112-01 Rev H0 
     
    To View Output Monitoring 
    1 Navigate to the Monitor page. 
    2 In the tree menu, select the Output/Card/RF Port. 
    Result: Output monitoring is shown for each QAM Card. 
      
    						
    							 
     
     Status Monitoring 
     
    78-4025112-01 Rev H0 111 
     
     
    To View Data Monitoring 
    1 Navigate to the Monitor page. 
    2 In the tree menu, select Data. 
    Result: Data monitoring is revealed for each GbE port. 
      
    						
    							 
    Chapter 6    Wideband Data Specific Operation  
     
     
    112 78-4025112-01 Rev H0 
     
    To View Input Details 
    Additional input information (for the output stream) can be retrieved by pressing 
    the Input/Details button on the output monitoring screen. 
    Result: The following screen is displayed. 
     
     
      
    						
    							 
     
    78-4025112-01 Rev H0 113 
     
    Introduction 
    This section provides information for provisioning the RF Gateway 1 
    for DOCSIS compliant M-CMTS operation.  
     
     
    7 Chapter 7 
    Basic M-CMTS Data Specific 
    Operation 
    In This Chapter 
     Provisioning ......................................................................................... 114 
     Status Monitoring ............................................................................... 119  
    						
    							 
    Chapter 7    Basic M-CMTS Data Specific Operation  
     
     
    114 78-4025112-01 Rev H0 
    Provisioning 
    This section provides information for provisioning the RF Gateway 1 for M-CMTS 
    operation. 
    Prerequisite configurations:  
     GbE input ports, including Video/Data IP address 
     QAM outputs 
     Channel Application Mode  
    Channel Application Mode 
    To Verify Channel Application Mode 
    1 Navigate to the Maps page. 
    2 In the tree menu, select Map Configuration. 
    Result: Channel Application Mode is revealed for each output carrier.  
    Note: The correct setting is Data. 
      
    Data Map Configuration 
    For a specific output carrier, using the Maps/Data Map web page, the operator can 
    configure: 
     Input Stream Type 
     Allowable ingress port or port-pair 
     Input stream DEPI Session ID port  
    						
    							 
     
     Provisioning 
     
    78-4025112-01 Rev H0 115 
     
    Note: Once a carrier is in data mode, the Data Map becomes active for that carrier.  
    The Data Map serves as a routing table which maps incoming data to unique output 
    carriers. 
    To Configure the Data Map 
    1 Navigate to the Maps page. 
    2 In the tree menu, select Data Map. 
    Result: The following window is displayed. 
     
    3 Configure the Stream Type to be DOCSIS MPT without UDP for the desired 
    carrier.  
    Note: The Stream Type setting of the RFGW-1-D is dependent upon the rf-
    channel configuration for the relevant controller modular-Cable in the CMTS. 
    The following table lists the valid Stream Type settings for each of the rf-channel 
    options in the uBR10K. 
    rf-channel (CMTS) Stream Type (RFGW-1-D) 
    udp-port MPEG 
    depi-remote-id DOCSIS MPT w/o UDP 
    In DOCSIS 2.0 Cisco Wideband operation, the eQAM device carries only 
    wideband channels (non-primary DOCSIS).  For non-primary flows in DOCSIS 
    2.0 Cisco Wideband operation, rf-channels are typically configured as udp-ports 
    in the CMTS, and the valid Stream Type is MPEG. For DOCSIS 3.0 Cisco 
    Wideband operation, most operators are migrating to using depi-remote-id for 
    all rf-channels.  This is done primarily to provide flexibility in defining primary 
    and non-primary channels.  For flows defined as depi-remote-id in the CMTS, 
    the valid Stream Type is DOCSIS MPT w/o UDP.  
    						
    							 
    Chapter 7    Basic M-CMTS Data Specific Operation  
     
     
    116 78-4025112-01 Rev H0 
    4 Select the Allowable Ingress Ports which receives the flows from the CMTS.  
    The correct GbE port (independent mode) or port pair (port-pair mode) will have 
    its GbE port physical address (independent mode) or Video/Data IP address 
    (port-pair mode) under the System/IP Network web view configured to match 
    the eQAM IP address in the CMTS. 
    5 Enter the Destination UDP Port for the input stream to be mapped out to the 
    relevant RF Gateway 1 carrier.  The Destination UDP Port must match the udp-
    port of the corresponding rf-channel in the CMTS. 
    Notes:  
    – Session ID will automatically set to N/A when Stream Type is MPEG. 
    – For a given ingress port pair, the UDP port or session ID must be unique. 
    6 Click Apply. 
    7 Click Save.  
    Connecting to DTI Server 
    The RF Gateway 1 chassis provides redundant RJ-45 connections for connecting to 
    DTI server devices.  These connectors are located along the bottom row of RJ-45 
    connectors on the rear panel of the RF Gateway 1 chassis. 
     
    To Connect To DTI Server 
    1 Locate the DTI ports on the rear panel of the RF Gateway 1 chassis. 
    2 Connect the RF Gateway 1 to the timing server network using CAT5 cable. 
    To Configure DTI 
    1 Navigate to the System page.  
    						