Factory Default Settings 78-4021470-01 Rev J 297 DPM - ASI Parameter Default PMT 8192 Act Drop OutCh 0 PMT 8191 Map Mode SVC ID & PID Duplic Mode Pkt Copy Unref Drop PSI Options Drop All PSI Rate SA Std Service ID Valid Ch PAT Pass CAT Pass PMT Pass TSDT Pass NIT Pass NITO Pass SDT Pass SDTO Pass BAT Pass EIT Pass TDT Pass RST Pass TOT Pass DIT Pass SIT Pass ECM Pass EMM Pass DRT Pass
Appendix B Default Settings 298 78-4021470-01 Rev J Parameter Default CDT Pass Noise Cutoff Parameter Default Trnsprt (DVB-S/DVB-S2 Marg) Cutoff 0.0 Trnsprt (DVB-S/DVB-S2 Marg) Restore 0.1 Audio (DVB-S/DVB-S2 Marg) Cutoff 0.0 Audio (DVB-S/DVB-S2 Marg) Restore 0.1 Muting Control Enable Import/Export (Web GUI only) Parameter Default Settings File Name file name FTP Server IP Address 192.168.0.100 FTP Port Number 21 FTP User Name user FTP Password USER
DPM Default Settings for Different Output Modes 78-4021470-01 Rev J 299 DPM Default Settings for Different Output Modes The DPM parameters are preset to default settings for each DPM Output Mode. The default settings for particular Output modes have been preset to optimize the output when PID mapping is required. If the DPM parameters are changed to values which switch the receiver to Full DPM Control, the receiver may enter a condition where conflicts in the settings may occur, which may require manual manipulation of the DPM or output parameters to obtain the desired output. The fields labeled “Any” in the table below are not used, in which case, the Output Mode will not change if the parameter is changed. However, if you change any of the other parameters listed in the table for the MAP output modes, the Output Mode will change to Full DPM Control. Output Mode No Output Passthrough Service Chans Only MAP Passthrough MAP Svc Chans Only Full DPM Control Rate Control Any (unchanged) Any (unchanged) Any (unchanged) Any (unchanged) Any (unchanged) Any (unchanged) User Rate Any (unchanged) Any (unchanged) Any (unchanged) Any (unchanged) Any (unchanged) Any (unchanged) Descramble Mode Any (unchanged) Any (unchanged) Any (unchanged) Any (unchanged) Any (unchanged) Any (unchanged) Regenerate Any (unchanged) Any (unchanged) Any (unchanged) Any (unchanged) Any (unchanged) Any (unchanged) Insert Null Packet Any (unchanged) Any (unchanged) Any (unchanged) Any (unchanged) Any (unchanged) Any (unchanged) Map Mode Any (not used) Svc ID Svc ID Svc Id & PID Svc ID & PID Actual Value Duplic Mode Any (not used) PSI Remap PSI Remap Pkt Copy Pkt Copy Actual Value Unref Drop Pass Drop Pass Drop Actual Value PSI Options Drop Ctl By Table Ctl By Table Ctl By Table Ctl By Table Actual Value PSI Rate Any (not used) SA Std SA Std SA Std SA Std Actual Value Svc ID Any (not used) Valid Ch Valid Ch Valid Ch Valid Ch Actual Value PAT Not Displayed Pass Regen Regen Regen Actual Value
Appendix B Default Settings 300 78-4021470-01 Rev J Output Mode No Output Passthrough Service Chans Only MAP Passthrough MAP Svc Chans Only Full DPM Control CAT Not Displayed If Descramble Mode is set to Descrambled, it is set to Regen; otherwise, it is set to Pass If Descramble Mode is set to Descrambled, it is set to Regen; otherwise, it is set to Pass If Descramble Mode is set to Descrambled, it is set to Regen; otherwise, it is set to Pass If Descramble Mode is set to Descrambled, it is set to Regen; otherwise, it is set to Pass Actual Value PMT Not Displayed If Descramble Mode is set to Descrambled, it is set to Regen; otherwise, it is set to Pass If Descramble Mode is set to Descrambled, it is set to Regen; otherwise, it is set to Pass Regen Regen Actual Value TSDT Not Displayed Pass Pass Pass Pass Actual Value NIT Not Displayed Pass Regen Regen Regen Actual Value NITO Not Displayed Pass PwRc PwRc PwRc Actual Value SDT Not Displayed If Descramble Mode is set to Descrambled, it is set to Regen; otherwise, it is set to Pass Regen Regen Regen Actual Value SDTO Not Displayed If Descramble Mode is set to Descrambled, it is set to Regen; otherwise, it is set to Pass PwRc PwRc PwRc Actual Value BAT Not Displayed If Descramble Mode is set to Descrambled, it is set to PwRC; otherwise, it is set to Pass PwRC PwRC PwRC Actual Value EIT Not Displayed Pass Pass Pass Pass Actual Value
DPM Default Settings for Different Output Modes 78-4021470-01 Rev J 301 Output Mode No Output Passthrough Service Chans Only MAP Passthrough MAP Svc Chans Only Full DPM Control TDT Not Displayed Pass Pass Pass Pass Actual Value RST Not Displayed Pass Pass Pass Pass Actual Value TOT Not Displayed Pass Pass Pass Pass Actual Value DIT Not Displayed Pass Pass Pass Pass Actual Value SIT Not Displayed Pass Pass Pass Pass Actual Value ECM Not Displayed Pass Pass Pass Pass Actual Value EMM Not Displayed Pass Pass Pass Pass Actual Value DRT Not Displayed Pass Pass Pass Pass Actual Value CDT Not Displayed Pass Pass Pass Pass Actual Value PE Action (all PEs) Drop Pass Pass Map Map Actual Value
78-4021470-01 Rev J 303 C Appx auto letter Appendix C Lock Levels Introduction This appendix contains the lock levels for the D9854 Advanced Program Receiver. In This Appendix D9854 Receiver Lock Levels .............................................................. 304
Appendix C Lock Levels 304 78-4021470-01 Rev J D9854 Receiver Lock Levels Four (4) lock levels (0, 1, 2, 3, and 4) are available for protecting your receiver and its settings against unauthorized use or modification (see the table below for full details). Level Description 0 All settings are unlocked (receiver lockout disabled) 1 All settings are unlocked except Factory Reset, Password options and receiver parameters. 2 All settings are unlocked except RF and ASI Input Tuning parameters. 3 All settings locked (access via password only), except IP address and RF power. 4 All settings locked (can be changed via PNC uplink signal only) If a change made to the current Lock Level setting is not saved, the previously saved setting is restored. Note: The user cannot select NONE as a Lock Level. Video Parameter Lock Level PV Format 2 SD Format 2 Aspect Ratio Parameter Lock Level SD Aspect Ratio 2 AR Selection 2 AR Conversion 2 WSS Mode 2
D9854 Receiver Lock Levels 78-4021470-01 Rev J 305 Closed Caption Parameter Lock Level Preferred Mode 2 Subtitles Parameter Lock Level Op Mode 2 Lang Menu 2 Lang List 2 PMT Order 2 Manual Entry 2 Imitext Position 2 Foreground 2 Background 2 Download Parameter Lock Level Mode 2 DL Type 2 DL Bank 2 Command 2 Runnable Application Parameter Lock Level Index 2 Select 2 Erase 2
Appendix C Lock Levels 306 78-4021470-01 Rev J Runnable FPGA Parameter Lock Level Index 2 Select 2 Erase 2 Audio Parameter Lock Level Audio Sel Key 2 Mode 2 AC3 Comp 2 Left 2 Right 2 PMT Source 2 PV Muting Thresholds Parameter Lock Level Transport Cutoff 2 Transport Restore 2 Audio Cutoff 2 Audio Restore 2 LDPC Muting Thresholds Parameter Lock Level Transport Cutoff 2 Transport Restore 2 Audio Cutoff 2