Cisco D9854i Manual
Have a look at the manual Cisco D9854i Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 53 Cisco manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
Fault History ............................................................................................................ 315 Log History .............................................................................................................. 316 Appendix D Compliance 317 Applicable Standards and Notices .................................................................................... 318 Safety ........................................................................................................................ 318 EMC .......................................................................................................................... 318 Electromagnetic Compatibility Regulatory Requirements ............................... 318 FCC Notices ............................................................................................................. 319 Industry Canada Notice ......................................................................................... 319 Unauthorized Modifications ................................................................................. 319 Declaration of Conformity .................................................................................................. 320 Index 321
About This Manual 78-4021470-01 Rev J xxiii About This Manual Objective This manual describes how to install, use and maintain the Cisco® D9854 Advanced Program Receiver. Note: The manual describes all available options for the D9854 receiver. Your D9854 receiver may only have some of the features described in this manual. Audience The audience of this manual includes users (operators) and service personnel who are responsible for the installation, configuration, operation, monitoring and service of the D9854 receiver. Required Knowledge To use this documentation, the user should have a basic knowledge of the technology used in relation to this product. Service personnel should have additional skills and be familiar with cabling, electronic circuitry, and wiring practices. This manual is intended for operators who are responsible for the configuration, remote operation and maintenance of the D9854 receiver.
78-4021470-01 Rev J 1 Overview This chapter provides a quick setup for your D9854 receiver. If you are unsure about which receiver settings to use, contact your local service provider for assistance. 1 Chapter 1 Quick Setup - Read Me First! In This Chapter Connecting the Receiver to Other Equipment .................................... 2 Setting up for Network Connection ..................................................... 4 Quick Setup Instructions for RF Acquisition ...................................... 5 Assigning a Program Channel to a PE (Program Entry) ................... 7 ASI Out ..................................................................................................... 8 Setting up the HD-SDI Outputs (SDI Model, with SD/HD-SDI and AES outputs) .................................................................................... 9 Setting up the MOIP Outputs (Base Model) ..................................... 10 Setting the DPM Mode ......................................................................... 11
Chapter 1 Quick Setup - Read Me First! 2 78-4021470-01 Rev J Connecting the Receiver to Other Equipment The following displays the rear panel of the D9854 Base Model: The following displays the rear panel of the D9854 SDI Model, with SD/HD-SDI and AES outputs: 1 Connect the L-Band signal to RF1. 13V or 18V LNB power is only available on the RF1 port. The factory default setting for LNB power is OFF. 2 Connect the ASI OUT port to an ASI device for digital tier applications. 3 Connect the Composite Video Output to a video monitor. 4 Connect the terminal block balanced audio outputs labeled AUDIO 1 and AUDIO 2 to monitoring equipment. 5 Apply power by connecting the receiver to a power outlet. The message “Application Starting” will appear on the front panel. The boot process approximately 1 minute for the unit to initialize. When ready, the front panel display shows the startup screen. 6 The Ethernet Management port does not currently provide SNMP or management control. It is used for software application downloads only. 7 Connect the HD-SDI outputs (M1 and M2) to HD compatible signal processing equipment or HD signal monitoring equipment, if applicable.
Connecting the Receiver to Other Equipment 78-4021470-01 Rev J 3 Maintenance of EMC Compliance The power cord (consisting of appliance coupler, flexible cord, and plug) supplied with this product meets the requirements for use in the country for which this product was purchased. In general, the power cord must be approved by an acceptable, accredited agency responsible for evaluation in the country where the product will be used. Double-shielded (braid/foil or braid/braid) cables should be used for all ASI I/O and RF inputs. Single-shield cables are acceptable for all other inputs and outputs. For terminal block (Alarms) I/O, no shielding is required.
Chapter 1 Quick Setup - Read Me First! 4 78-4021470-01 Rev J Setting up for Network Connection 1 Press MENU to display the Main menu. 2 Press to go to the Setup menu. Press SELECT. Press twice to select the IP menu. Press SELECT twice to go to the IP menu. 3 Use the arrow keys to navigate up and down the IP menu, and the arrow keys to move across the IP menu to set the IP Address, Mask and Gateway parameters. Use the number keys to directly enter numbers in the fields. For more information on keypad operation, see Keypad Convention. 4 Press SELECT each time to save the changes. Press MENU four times to return to the startup screen.
Quick Setup Instructions for RF Acquisition 78-4021470-01 Rev J 5 Quick Setup Instructions for RF Acquisition 1 Press MENU to display the Main menu. 2 Press to go to the Setup menu. Press SELECT. Press to move to the TS Input menu. Press SELECT. 3 To setup the ASI input port, go to step 4. To setup the RF1 input port, go to step 5. 4 Press SELECT three times. Press to set the ASI port to Act (Activate). Press SELECT. Go to step 11. 5 Press SELECT. Press to go to RF1. Press SELECT twice. Use to set the RF1 port parameter to Act (Activate). Press SELECT. 6 Press to move to the LO1, LO2, Crossover menu. Verify these parameters for your application. If no change is needed, go to Step 7. If required, you may modify these settings. Use to move to the parameter that you want to modify. Press SELECT. Use the numerical keypad to enter new frequencies. Press SELECT. 7 Press five times to move to the Modulation and Rolloff menu. Press SELECT. Use to choose DVB-S or DVB-S2. Press SELECT. If DVB-S2 is used, press to choose Rolloff. Press SELECT. Use to choose the value. Press SELECT. 8 Press to move to the Freq., Sym Rate, and FEC menu. Press SELECT. Enter the RF frequency. Press SELECT. Press to move to the Sym. Rate menu. Press SELECT. Enter the symbol rate. Press SELECT. If DVB-S2 is used, proceed to step 9. If DVB-S is used, press to set up the FEC. Press SELECT. Use to select AUTO. Press SELECT. 9 Press twice to move to the Net ID menu. Press to choose Net ID. Press SELECT. Enter the value. Press SELECT. 10 Press . Press SELECT. Use to change the LNB power, if needed. Only the RF1 port is capable of providing 13V or 18V. Press SELECT. 11 Press MENU three times. Press to move to Save & Exit. Press SELECT. Save & Exit will return you to the Main: Setup menu; Abandon & Exit will go back to the last menu accessed with the original parameters; Cancel will go back to the last menu accessed with changes saved. 12 The receiver will search for the signal and display “Acquisition Successful”. It will find the first available channel on the network. Press MENU twice to return to the start-up menu.
Chapter 1 Quick Setup - Read Me First! 6 78-4021470-01 Rev J 13 If the front LED is solid green, the unit is authorized. Proceed with Assigning a Program Channel to a PE (Program Entry). If the front LED is flashing green, the unit is unauthorized. Please contact your service provider and provide the Tracking ID number for authorization. The Tracking ID can be found on the ABOUT menu. To locate the Tracking ID, press MENU, press twice, and then press SELECT twice. Make a note of the Tracking ID number. Press MENU three times to return to the startup screen.