Page 111
Appendices105 Chapter 4 6.Wipe the removed rollers with a firmly wrung cloth moistened with water. IMPORTANT Do not use detergent to clean the rollers, since any detergent on the rollers could cause a feeding error. 7.Attach the rollers that werw removed. - See “Attaching the Pickup Roller,” on p. 115. - See “Attaching the Feed Roller,” on p. 118. - See “Attaching the Retard Roller,” on p. 121. 8.Be sure that the upper unit is completely closed by pushing on both edges with both hands until you hear a...
Page 112
106Appendices Cleaning the Shading Boards The shading boards are the white standard boards located behind the platen rollers. A dirty shading board may alter scanned colors or cause marks on the images. 1.Turn ON the power. 2.Hold the upper unit as shown in the diagram, and open it slowly until it stops. CAUTION The pickup roller is located in the middle of the upper unit. Do not hold the protrusion on the upper unit when you open it. Doing so may deform the pickup roller or cause a feeding error....
Page 113
Appendices107 Chapter 4 5.Press the stop button. The shading board goes back in. 6.Close the upper unit slowly. Be sure that the upper unit is completely closed by pushing on both edges with both hands until you hear a click. IMPORTANT Do not force the upper unit to close. Doing so may damage the scanner.
Page 114
108Appendices 2. Removing and Attaching the Rollers Follow the relevant procedure to remove and attach the pickup roller, feed rollers and retard roller when you clean or replace them. IMPORTANT Feed rollers are consumable parts. When the rollers start to wear out, paper jams and misfeeds may occur more often. When this happens, buy a exchange roller kit, and replace the pickup roller, feed rollers and the retard roller. CAUTION • Turn ON the power to the scanner to remove or attach the pickup...
Page 115
Appendices109 Chapter 4 Resetting the Counter After replacing the feed rollers, open the [Counter setup] dialog box and reset the counter. 1.Follow the procedure below to open the [CANON DR-6030C USB Properties] (or [CANON DR-6030C SCSI Properties]) dialog box. 1. Click the [Start] button, and then click [Control Panel].
Page 116
110Appendices 2. This operation depends on your operating system. „Windows XP Switch the Control Panel to Classic View, or select [Printers and Other Hardware] in the working field. „ Windows Vista Switch the Control Panel to Classic View, or select [Hardware and sound] in the working field. „ Windows 7 Click [View by] at the upper-right of the Control Panel, and then select [Large icons] or [Small icons] from the list, or select [Hardware and Sound] in the category view. Printers and Other...
Page 117
Appendices111 Chapter 4 3. Click [View devices and printers]. (For Windows XP and Windows Vista, click [Scanners and Cameras].) 4. Select [CANON DR-6030C] (or [CANON DR-6030C SCSI]), and then click the right mouse button and select [Properties]. (For Windows XP and Windows Vista, select [CANON DR-6030C USB] (or [CANON DR-6030C SCSI]), and then click [Properties].)
Page 118
112Appendices [CANON DR-6030C USB Properties] (or [CANON DR-6030C SCSI Properties]) is displayed. 2.Click the [Maintenance] tab.
Page 119
Appendices113 Chapter 4 3.Click the [Reset] button, and then make sure that the counter for the roller being used is set to 0. Removing and Attaching the Pickup Roller When cleaning or replacing the pickup roller, feed rollers or retard roller, use the appropriate procedure to remove and replace the rollers. CAUTION • Turn ON the power to the scanner to remove or attach the pickup roller. Be careful when working on the scanner when the power is ON. • Do not use excessive force when removing or...
Page 120
114Appendices Removing the Pickup Roller 1.Turn ON the power. Note Because the pickup roller locks when the power is OFF, it will not fall forward when the upper unit is opened. 2.Hold the upper unit as shown in the diagram, and open it slowly until it stops. CAUTION The pickup roller is located in the middle of the upper unit. Do not hold the protrusion on the upper unit when you open it. Doing so may deform the pickup roller or cause a feeding error. 3.Push up on the pickup roller to open the hook,...