Home > Brother > Printer > Brother Hl 4040cn User Manual

Brother Hl 4040cn User Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Brother Hl 4040cn User Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 331 Brother manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Appendix
    182
    A
    This parameter selects the bar code mode as shown above. When n is ‘t5’ or ‘T5’ the bar code mode (EAN 
    8, EAN 13, or UPC A) varies according to the number of characters in the data.
    Bar code, expanded character, line block drawing and box drawingA
    This parameter chooses the bar code style as above. When the EAN 8, EAN 13, UPC-A, Code 128 or EAN 
    128 bar code mode is chosen, this bar code style parameter is ignored.
    Expanded Character
    ‘S’
    0 = White
    1 = Black
    2 = Vertical stripes
    3 = Horizontal stripes
    4 = Cross hatch
    For example ‘S’ n1 n2
    n1 = Background fill pattern
    n2 = Foreground fill pattern
    If ‘S’ is followed by only one parameter, the parameter is a foreground fill pattern.
    Line block drawing & box drawing
    ‘S’
    1 = Black
    2 = Vertical stripes
    3 = Horizontal stripes
    4 = Cross hatch
    Bar code A
    n = ‘mnnn’ or ‘Mnnn’ (nnn = 0 ~ 32767)
    This parameter shows the bar code width. The unit of ‘nnn’ is a percentage.n = ‘s0’ or ‘S0’ 3: 1 (default)
    n = ‘s1’ or ‘S1’ 2: 1
    n = ‘s3’ or ‘S3’ 2.5: 1
     
    						
    							Appendix
    183
    A
    Bar code human readable line ON or OFFA
    This parameter shows whether the printer prints the human readable line below the bar code. Human 
    readable characters are always printed with OCR-B font of 10 pitch and all the current character style 
    enhancements are masked. The default setting is determined by the bar code mode selected by ‘t’ or ‘T’.
    Quiet zoneA
    n = ‘onnn’ or ‘Onnn’ (nnn = 0 ~ 32767)
    Quiet zone is the space on both sides of the bar codes. Its width can be shown using the units that are set by 
    the ‘u’ of ‘U’ parameter. (For the description of ‘u or ‘U parameter, see the next section.) The default setting 
    of the quiet-zone width is 1 inch.
    Bar code, expanded character unit, line block drawing and box drawingA
    This parameter shows the measurement units of X-axis offset, Y-axis offset, and bar code height.
    Bar code, expanded character, line block drawing and box drawing offset in X-axisA
    n = ‘xnnn’ or ‘Xnnn’
    This parameter shows the offset from the left margin in the ‘u’- or ‘U’-specified unit.n = ‘r0’ or ‘R0 Human readable line OFF
    n = ‘r1’ or ‘R1 Human readable line ON
    Preset: Human readable line ON
    (1) ‘T5’ or ‘t5’
    (2) ‘T6’ or ‘t6’
    (3) ‘T130’ or ‘t130’
    (4) ‘T131’ or ‘t131’
    Preset: Human readable line OFF
    All others
    n = ‘u0’ or ‘U0’ mm (preset)
    n = ‘u1’ or ‘U1’ 1/10
    n = ‘u2’ or ‘U2’ 1/100
    n = ‘u3’ or ‘U3’ 1/12
    n = ‘u4’ or ‘U4’ 1/120
    n = ‘u5’ or ‘U5’ 1/10 mm
    n = ‘u6’ or ‘U6’ 1/300
    n = ‘u7’ or ‘U7’ 1/720
     
    						
    							Appendix
    184
    A
    Bar code & expanded character offset in Y-axisA
    n = ‘ynnn’ or ‘Ynnn’
    This parameter shows the downward offset from the current print position in the ‘u’- or ‘U’-specified unit.
    Bar code, expanded character, line block drawing and box drawing heightA
    n = ‘hnnn’, ‘Hnnn’, ‘dnnn’, or ‘Dnnn’
    1 EAN13, EAN8, UPC-A, ISBN (EAN13, EAN8, UPC-A), ISBN (UPC-E): 22 mm
    2 UPC-E: 18 mm
    3 Others: 12 mm
    Expanded characters i 2.2 mm (preset)
    Line block drawing and box drawing i 1 dot
    This parameter shows the height of bar codes or expanded characters as shown above. It can start with ‘h’, 
    ‘H’, ‘d’, or ‘D’. The height of bar codes is shown in the ‘u’- or ‘U’-specified unit. The default setting of the bar 
    code height (12 mm, 18 mm or 22 mm) is determined by the bar code mode selected by ‘t’ or ‘T’.
    Expanded character width, line block drawing and box drawingA
    n = ‘wnnn’ or ‘Wnnn’
    Expanded character i 1.2 mm
    Line block drawing and box drawing i 1 dot
    This parameter shows the width of expanded characters as shown above.
    Expanded character rotationA
    Bar code data startA
    n = ‘b’ or ‘B’
    Data that follows ‘b’ or ‘B’ is read in as bar code data. Bar code data must end with the ‘  ’ code (5CH), which 
    also ends this command. The acceptable bar code data is determined by the bar code mode selected by ‘t’ 
    or ‘T’.
    When CODE 39 is chosen with the parameter ‘t0’ or ‘T0’
    Forty three characters ‘0’ to ‘9’, ‘A’ to ‘Z’, ‘-’, ‘ . ’, ‘ (space)’, ‘$’, ‘ / ’, ‘+’, and ‘%’ can be accepted as bar code 
    data. Other characters will cause a data error. The number of characters for bar codes is not limited. The 
    bar code data automatically starts and ends with an asterisk ‘ * ’ (start character and stop character). If the 
    received data has an asterisk ‘ * ’ at the beginning or end, the asterisk is regarded as a start character or 
    stop character. n = ‘a0’ or ‘A0’ ‘Upright (preset)
    n = ‘a1’ or ‘A1’ ‘Rotated 90 degrees
    n = ‘a2’ or ‘A2’ ‘Upside down, rotated 180 degrees
    n = ‘a3’ or ‘A3’ ‘Rotated 270 degrees
     
    						
    							Appendix
    185
    A
    When Interleaved 2 of 5 is selected with the parameter ‘t1’ or ‘T1’:
    Ten numerical characters ‘0’ to ‘9’ can be accepted as bar code data. Other characters cause a data error. 
    The number of characters for bar codes is not limited. This mode of bar codes needs even characters. If 
    the bar code data has odd characters, ‘0’ is automatically added to the end of the bar code data.
    When FIM (US-Post Net) is selected with the parameter ‘t3’ or ‘T3’
    Characters ‘A’ to ‘D’ are valid and one digit of data can be printed. Upper-case and lower-case alphabet 
    characters can be accepted.
    When Post Net (US-Post Net) is selected with the parameter ‘t4’ or ‘T4’
    Numbers ‘0’ to ‘9 can be data and it must end with a check digit. ‘?’ can be used instead of the check digit.
    When EAN 8, EAN 13, or UPC A is selected with the parameter ‘t5’ or ‘T5’
    Ten numbers ‘0’ to ‘9’ can be accepted as bar code data. The number of characters for bar codes is limited 
    as follows:
    EAN 8: Total 8 digits (7 digits + 1 check digit)
    EAN 13: Total 13 digits (12 digits + 1 check digit)
    UPC A: Total 12 digits (11 digits + 1 check digit)
    A number of characters other than those stated above will cause a data error that results in the bar code 
    data being printed as normal print data. If the check digit is not correct, the printer decides the correct 
    check digit automatically so that the correct bar code data will be printed. When EAN13 is selected, adding 
    ‘+’ and a two-digit or five-digit number after the data can create an add-on code.
    When UPC-E is selected with the parameter ‘t6’ or ‘T6’:
    The numbers ‘0’ to ‘9’ can be accepted as bar code data.
    1‘?’ can be used instead of a check digit.
    2Adding ‘+’ and two-digit or five-digit number after the data creates an add-on code.
    When Codebar is chosen with the parameter ‘t9’ or ‘T9’
    Characters ‘0’ to ‘9’, ‘-’, ‘ . ’, ‘$’, ‘/’, ‘+’, ‘ : ’ can be printed. Characters ‘A’ to ‘D’ can be printed as a start-
    stop code, which can be upper case or lower case. If there is no start-stop code, errors will happen. A 
    check digit cannot be added and using ‘?’ causes errors.
    When Code 128 Set A, Set B, or Set C is selected with the parameter ‘t12’ or ‘T12’, ‘t13’ or ‘T13’, or ‘t14’ 
    or ‘T14’
    Code 128 sets A, B and C can be individually selected. Set A shows characters Hex 00 to 5F. Set B 
    includes characters Hex 20 to 7F. Set C includes the pairs 00 to 99. Switching is allowed between the code 
    sets by sending %A, %B, or %C. FNC 1, 2, 3, and 4 are produced with %1, %2, %3, and %4. The SHIFT 
    code, %S, allows temporary switching (for one character only) from set A to set B and vice versa. The ‘%’ 
    character can be encoded by sending it twice.
    When ISBN (EAN) is selected with the parameter ‘t130’ or ‘T130’
    The same rules apply as for ‘t5’ or ‘T5’. Eight digits
    12(standard format) The first character must be ‘0’ and the data must end with a check digit.
    Total eight digits = ‘0’ plus 6 digits plus 1 check digit.
    Six digits
    2The first character and the last check digit are removed from the eight digit data. 
     
    						
    							Appendix
    186
    A
    When ISBN (UPC-E) is selected with the parameter ‘t131’ or ‘T131’:
    The same rules apply as for ‘t6’ or ‘T6’.
    When EAN 128 set A, set B or set C is selected with the parameter ‘t132’ or ‘T132’, ‘t133’ or ‘T133’ or ‘t134’ 
    or ‘T134’
    The same rules apply as for ‘t12’ or ‘T12’, ‘t13’ or ‘T13’, or ‘t14’ or ‘T14’.
    Box drawingA
    ESC i ... E (or e)
    ‘E’ or ‘e’ is a terminator.
    Line block drawingA
    ESC i ... V (or v)
    ‘V’ or ‘v’ is a terminator.
    Expanded character data startA
    n = ‘l’ or ‘L’
    Data that follows ‘l’ or ‘L’ is read as expanded character data (or labeling data). Expanded character data must 
    end with the ‘  ’ code (5CH), which also ends this command.
    Example Program Listings
    A
    WIDTH LPT1:,255
    CODE 39
    LPRINT CHR$(27);it0r1s0o0x00y00bCODE39?\;
    Interleaved 2 of 5
    LPRINT CHR$(27);it1r1s0o0x00y20b123456?\;
    FIM
    LPRINT CHR$(27);it3r1o0x00y40bA\;
    Post Net
    LPRINT CHR$(27);it4r1o0x00y60b1234567890?\;
    EAN-8
    LPRINT CHR$(27);it5r1o0x00y70b1234567?\;
    UPC-A
    LPRINT CHR$(27);it5r1o0x50y70b12345678901?\;
    EAN-13
    LPRINT CHR$(27);it5r1o0x100y70b123456789012?\;
    UPC-E
    LPRINT CHR$(27);it6r1o0x150y70b0123456?\;
     
    						
    							Appendix
    187
    A
    Codabar
    LPRINT CHR$(27);it9r1s0o0x00y100bA123456A\;
    Code 128 set A
    LPRINT CHR$(27);it12r1o0x00y120bCODE128A12345?\;
    Code 128 set B
    LPRINT CHR$(27);it13r1o0x00y140bCODE128B12345?\;
    Code 128 set C
    LPRINT CHR$(27);it14r1o0x00y160b;CHR$(1);CHR$(2);?\;
    ISBN(EAN)
    LPRINTCHR$(27);it130r1o0x00y180b123456789012?+12345\;
    EAN 128 set A
    LPRINT CHR$(27);it132r1o0x00y210b1234567890?\;
    LPRINT CHR$(12)
    END
     
    						
    							188
    B
    B
    Brother numbersB
    IMPORTANT
    For technical and operational help, you must call the country where you bought the printer. Calls must be 
    made from within that country.
     
    Register your productB
    By registering your Brother product, you will be recorded as the original owner of the product.
    Your registration with Brother:
    may serve as a confirmation of the purchase date of your product should you lose your receipt;
    may support an insurance claim by you in the event of product loss covered by insurance; and,
    will help us to notify you of enhancements to your product and special offers.
    Please complete the Brother Warranty Registration or, for your convenience and most efficient way to register 
    your new product, register on-line at
     
    http://www.brother.com/registration/
     
    Frequently asked questions (FAQs)B
    The Brother Solutions Center is our one-stop resource for all your printer needs. You can download the latest 
    drivers, software and utilities, read FAQs and troubleshooting tips to learn how to get the most from your 
    Brother product.
     
    http://solutions.brother.com
     
    You can check here for Brother driver updates.
    Customer Service
    B
    Visit http://www.brother.com for contact information on your local Brother office.
    Service center locations
    B
    For service centres in Europe, contact your local Brother Office. Address and telephone contact information 
    for European offices can be found at http://www.brother.com
     by selecting your country.
    Appendix (for Europe and Other 
    Countries)
    B
    Internet A ddresses
    Brother Global Web Site: http://www.brother.com
    For Frequently Asked Questions (FAQs), Product Support and Technical Questions, and Driver Updates and Utilities: 
    http://solutions.brother.com
     
    						
    							Appendix  (for Europe and Other Countri es)
    189
    B
    Important information: regulationsB
    Radio interference (220 to 240 volt model only)B
    This printer follows EN55022 (CISPR Publication 22)/Class B.
    Before you use this product, make sure that you use one of the following interface cables.
    1 A shielded parallel interface cable with twisted-pair conductors and that it is marked IEEE 1284 compliant 
    (HL-4050CDN / HL-4070CDW only).
    2 A USB cable.
    The cable must not be more than 2 meters long.
    IEC 60825-1 specification (220 to 240 volt model only )B
    This printer is a Class 1 laser product as defined in IEC 60825-1 +A2:2001 specifications. The label shown 
    below is attached in countries where it is needed.
     
    This printer has a Class 3B laser diode which produces invisible laser radiation in the laser unit. You should 
    not open the laser unit under any circumstances. 
     Caution
    B
    Use of controls or adjustments or performance of procedures other than those specified in this User’s Guide 
    may result in hazardous invisible radiation exposure. 
    For Finland and SwedenB
    LUOKAN 1 LASERLAITE
    KLASS 1 LASER APPARAT
     Varoitus!
    B
    Laitteen käyttäminen muulla kuin tässä käyttöohjeessa mainitulla tavalla saattaa altistaa käyttäjän 
    turvallisuusluokan 1 ylittävälle näkymättömälle lasersäteilylle.
     Varning
    B
    Om apparaten används på annat sätt än i denna Bruksanvisning specificerats, kan användaren utsättas för 
    osynlig laserstrålning, som överskrider gränsen för laserklass 1.
    CLASS 1 LASER PRODUCT
    APPAREIL À LASER DE CLASSE 1
    LASER KLASSE 1 PRODUKT
     
    						
    							Appendix  (for Europe and Other Countri es)
    190
    B
    Internal laser radiationB
    EU Directive 2002/96/EC and EN50419B
     
    (European Union only)
    This equipment is marked with the above recycling symbol. It means that at the end of the life of the 
    equipment you must dispose of it separately at an appropriate collection point and not place it in the normal 
    domestic unsorted waste stream. This will benefit the environment for all. (European Union only)
    IMPORTANT - for your safetyB
    To ensure safe operation, the supplied three-pin plug must be inserted only into a standard three-pin power 
    outlet that is properly grounded through the standard electrical wiring. 
    Extension cords used with this printer must be three-pin plug type and correctly wired to provide grounding. 
    Incorrectly wired extension cords may cause personal injury and equipment damage. 
    The fact that the equipment operates satisfactorily does not imply that the power is grounded and that the 
    installation is completely safe. For your safety, if in any doubt about the effective grounding of the power, call 
    a qualified electrician. 
    This product should be connected to an AC power source within the range indicated on the rating label. DO 
    NOT connect it to a DC power source. If you are not sure, contact a qualified electrician.
    Disconnect deviceB
    You must install this printer near a power outlet that is easily accessible. In case of an emergency, you must 
    disconnect the power cord from the power outlet to shut off the power completely.
    Caution for LAN connection B
    Connect this product to a LAN connection that is not subjected to overvoltages.Maximum radiation power: 25 mW
    Wave length: 780 - 800 nm
    Laser class: Class 3B
     
    						
    							Appendix  (for Europe and Other Countri es)
    191
    B
    IT power system (For Norway only)B
    This product is also designed for an IT power system with phase-to-phase voltage 230V.
    Wiring information (for UK)B
    ImportantB
    If you need to replace the plug fuse, fit a fuse that is approved by ASTA to BS1362 with the same rating as 
    the original fuse.
    Always replace the fuse cover. Never use a plug that does not have a cover.
    Warning - This printer must be earthed.
    B
    The wires in the mains lead are coloured in line with the following code:
    Green and Yellow: Earth
    Blue: Neutral
    Brown: Live
    If in any doubt, call a qualified electrician.
    Maschinenlärminformations- Verordnung 3. GPSGV (For Germany only)B
    Der höchste Schalldruckpegel beträgt 70 dB(A) oder weniger gemäß EN ISO 7779.
     
    						
    All Brother manuals Comments (0)

    Related Manuals for Brother Hl 4040cn User Manual