Page 151

16. Adjustment menu (check up)
16. ADJUSTMENT MENU (CHECK UP)
Overview
• Internal patterns
• Convergence
•More..
All items in the adjustment menu are given for check up. No adjustments are possible.
16.1 Internal patterns
How to select ?
1. PressMENUto activate the menu bar.
2. Press→to select theAdjustmentitem. (image 16-1)
3. Press↓to pull down theAdjustmentmenu.
4. Use↑or↓to selectInternal patterns.
5. Press→to pull down the menu.
6. Use↑or↓to select the desired test pattern.
The following test...

Page 152

16. Adjustment menu (check up)
16.2 Convergence
Only for check up of the convergence, no adjustment is possible in the field. When a convergence problem
occurred, contact a Barco service center.
How to select ?
1. PressMENUto activate the menu bar.
2. Press→to select theAdjustmentitem. (image 16-2)
3. Press↓to pull down theAdjustmentmenu.
4. Use↑or↓to selectConvergence.
5. Press→to pull down the menu.
6. Use↑or↓to select the desired convergence test pattern.
7. PressENTERto select.
The selected test...

Page 153

A. Standard Image Files
A. STANDARD IMAGE FILES
A.1 Table overview
Table overview
The following standard image files are pre-programmed in the projector.
Name4Resolution5Fvert
Hz
6
FHor
kHz
7
Fpix
MHz
8
Ptot9Pact10Ltot11Lact12
1600_48V1600x600i48,04062,500135,00021601600651600
CGA640x200i59,92415.70014.318912640262200
COMPUSC41024x480i29,94530,69439,77912961024512480
ED735x48059,94331,47028,638910735525480
EGA640x35059,70221,85116,257744640366350
FMR640x400i42,32336,44028,570784640431400...

Page 154

A. Standard Image Files
Name4Resolution5Fvert
Hz
6
FHor
kHz
7
Fpix
MHz
8
Ptot9Pact10Ltot11Lact12
MAC_6832x62474,54649,72257,2801152832667624
MAC_71024x76874,90760,15080,00013301024803768
MAC_LC640x48066,61934,97531,338896640525480
MAC_POR640x87074,99668,84657,280932640918870
NTSC675x2406015,74813,512858675263240
PA L675x2865015,62513,500864675313286
PAM500640x40060,00026,40022,810864640440400
PAM8001120x375i44,93636,44350,000137211 2 0406375
ProPAL686x5705027,25831,250864686625570...

Page 155

A. Standard Image Files
Name4Resolution5Fvert
Hz
6
FHor
kHz
7
Fpix
MHz
8
Ptot9Pact10Ltot11Lact12
UXGA_701600x12007087,497188,9932160160012501200
VGA_60640x4806031,32625,061800640525480
VGA_72640x4807337,86031,500832640520480
VGA_75640x48075,00037,50031, 500840640500480
VGA75ISO640x48075,00039,37531,500800640525480
VIDEO525680x239i29,97015,73432,207720680263239
VIDEO625680x278i25,00015,62531,984720680313278
XGA_431024x3848735,50044,87212641024409384
XGA_601024x76860,00048,36064,99613441024806768...

Page 156

A. Standard Image Files
152R5976816 RLM R6+ PERFORMER 21/12/2005 

Page 157

B. Maintenance of the Projector
B. MAINTENANCE OF THE PROJECTOR
B.1 Air Filters
About maintaining the air filters
It is recommended that you replace the air filters (located at the bottom of the projector) when you replace the lamp - or sooner, in
dusty or dirty environment. In the latter case,check monthlyif replacement is required.
A clogged filter reduces the air flow, and can lead to overheating and failure of the projector.
Location of the air filters
The air filters, in total 5 filters, are located...

Page 158

B. Maintenance of the Projector
AB
Image B-2
C
Image B-3
Available kit
All the 5 air filters are assembled to 1 kit, order numberR401045K
154
R5976816 RLM R6+ PERFORMER 21/12/2005 

Page 159

C. Specifications
C. SPECIFICATIONS
C.1 RLM R6+ Performer specifications
Overview
Light Output6000 ANSI Lumen
6500 Center lumen
Resolution1400 x 1050 (native)
Contrast ratio1600:1 (full field)
Lamp2 x 250 W mercury
Lamp warranty: 1000 hrs
Ambient temperatureMax 40°C (104°F)
Power consumption700 W
Mains Voltage92-240 V
WeightProjector: 25 kg (56 lbs)
Frame: 5kg(11lbs)
Dimensions (WxLxH)705 x 707,8 x 316,5 mm
(27.8 x 27.9 x 12.5 inch)
Sealed DLP™ coreStandard
ScenergiXStandard horizontal and vertical...

Page 160

C. Specifications
156R5976816 RLM R6+ PERFORMER 21/12/2005 