Barco Rlm R6+ Performer Owners Manual
Have a look at the manual Barco Rlm R6+ Performer Owners Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 183 Barco manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
16. Adjustment menu (check up) 16. ADJUSTMENT MENU (CHECK UP) Overview • Internal patterns • Convergence •More.. All items in the adjustment menu are given for check up. No adjustments are possible. 16.1 Internal patterns How to select ? 1. PressMENUto activate the menu bar. 2. Press→to select theAdjustmentitem. (image 16-1) 3. Press↓to pull down theAdjustmentmenu. 4. Use↑or↓to selectInternal patterns. 5. Press→to pull down the menu. 6. Use↑or↓to select the desired test pattern. The following test patterns are available: -Purity -Outline -Hatch - Color bars - Checkerboard - Full white -HGBWS - Character set 7. PressENTERto select. The selected test pattern will be displayed. Image 16-1 When character set is selected A character set is built up with several pages: 1. PressENTERfor the next set (page). 2. PressBACKfor previous set (page). 3. PressMENUto return to menu structure. R5976816 RLM R6+ PERFORMER 21/12/2005 147
16. Adjustment menu (check up) 16.2 Convergence Only for check up of the convergence, no adjustment is possible in the field. When a convergence problem occurred, contact a Barco service center. How to select ? 1. PressMENUto activate the menu bar. 2. Press→to select theAdjustmentitem. (image 16-2) 3. Press↓to pull down theAdjustmentmenu. 4. Use↑or↓to selectConvergence. 5. Press→to pull down the menu. 6. Use↑or↓to select the desired convergence test pattern. 7. PressENTERto select. The selected test pattern will be displayed. Image 16-2 16.3 More.. Access The items covered by More are only accessible for service technicians with a special key code. 148 R5976816 RLM R6+ PERFORMER 21/12/2005
A. Standard Image Files A. STANDARD IMAGE FILES A.1 Table overview Table overview The following standard image files are pre-programmed in the projector. Name4Resolution5Fvert Hz 6 FHor kHz 7 Fpix MHz 8 Ptot9Pact10Ltot11Lact12 1600_48V1600x600i48,04062,500135,00021601600651600 CGA640x200i59,92415.70014.318912640262200 COMPUSC41024x480i29,94530,69439,77912961024512480 ED735x48059,94331,47028,638910735525480 EGA640x35059,70221,85116,257744640366350 FMR640x400i42,32336,44028,570784640431400 hd_1080i1920x5406033,75074,24922001920563540 hd_24p1920x108024,00027,00074,0002750192011251080 hd_24sf1950x54048,00027,00074,00027501950562540 hd_25i1920x54050,00028,12574,00026401920562540 hd_25p1920x108025,00028,12574,0002640192011251080 hd_30p1920x108030,00033,75074,0002200192011251080 hd_60p1280x72060,00045,00074,00016501280750720 HDSDI SDI1920x954502761,91722001920563540 HDSDI 25P1920x1080252774,2502640192011521080 HDSDI 24P1920x10802425,98074,2502750192011521080 HDSDI 24S1920x5402412,96074,32427501920563540 HDSDI 60I1920x5406032,40074,33922001920563540 HDSDI 30P1920x10803032,40074,2492200192011251080 HDSDI 60P1280x7206074,25043,20016501280750720 INTER_GR1184x88667,17061,79692,941150411 8 4920886 MAC_3512x38460,14724,48015,667640512407384 MAC_4560_38460,14724,48017,234704560407384 MAC_5512x34260,15822,25916,670704512370342 4. Name: name of file, contains the settings. 5. Resolution: image resolution, when followed by ..i means interlaced. 6. Fvert Hz: vertical frame frequency of the source 7. FHor kHz: horizontal frequency of the source 8. Fpix MHz: pixel frequency 9. Ptot : total pixels on one horizontal line. 10. Pact: active pixels on one horizontal line. 11. Ltot: total lines in one field 12. Lact: active lines in one field. R5976816 RLM R6+ PERFORMER 21/12/2005149
A. Standard Image Files Name4Resolution5Fvert Hz 6 FHor kHz 7 Fpix MHz 8 Ptot9Pact10Ltot11Lact12 MAC_6832x62474,54649,72257,2801152832667624 MAC_71024x76874,90760,15080,00013301024803768 MAC_LC640x48066,61934,97531,338896640525480 MAC_POR640x87074,99668,84657,280932640918870 NTSC675x2406015,74813,512858675263240 PA L675x2865015,62513,500864675313286 PAM500640x40060,00026,40022,810864640440400 PAM8001120x375i44,93636,44350,000137211 2 0406375 ProPAL686x5705027,25831,250864686625570 ProNTSC735x4806028,66131,500910735525480 SDI_625675x278i25,00015,62513,500864720313278 SDI_525675x240i29,97015,73413,500858720263240 SG_501600x120050,00062,500130,3132085160012501200 SG_60_11280x102460,00063,900107,3521680128010651024 SG_60_21024x76860,00048,78064,39013201024813768 SG_60_3960x68060,00043,20054,4321260960720680 SG_60_41600x120060,00075,000156,3752085160012501200 SUNEWS671280x102467,18971,691117,0001632128010671024 SUNXGA601024x76859,98448,28764,12513281024805768 SUNXGA701024x76870,04156,59674,25013121024808768 SVGA_56800x60056,25035,15636,0001024800625600 SVGA_60800x60060,31737,87940,0001056800628600 SVGA_72800x60072,08448,08050,0031040800666600 SVGA_75800x60075,00046,87575,0001056800625600 SVGA_85800x60085,00053,63556,2501048800631600 SXGA_721280x10247276,699128,8541680128010611024 SXGA_751280x10247579,974134,9971688128010661024 SXGA_851280x10248591,149157,5061728128010721024 UXGA_601600x12006075,002162,0042160160012501200 UXGA_651600x12006581,248175,4962160160012501200 150R5976816 RLM R6+ PERFORMER 21/12/2005
A. Standard Image Files Name4Resolution5Fvert Hz 6 FHor kHz 7 Fpix MHz 8 Ptot9Pact10Ltot11Lact12 UXGA_701600x12007087,497188,9932160160012501200 VGA_60640x4806031,32625,061800640525480 VGA_72640x4807337,86031,500832640520480 VGA_75640x48075,00037,50031, 500840640500480 VGA75ISO640x48075,00039,37531,500800640525480 VIDEO525680x239i29,97015,73432,207720680263239 VIDEO625680x278i25,00015,62531,984720680313278 XGA_431024x3848735,50044,87212641024409384 XGA_601024x76860,00048,36064,99613441024806768 XGA_701024x76870,00056,47574,99913281024806768 XGA_721024x76871,95558,14080,00013761024808768 XGA_751024x7687560,02478,75213121024800768 XGA_851024x76885,00068,68094,50013761024808768 XGA_EOS1024x76863,00050,00067,20013441024796768 XGA75_GS1024x76874,53459,70179,28413281024801768 Table A-1 R5976816 RLM R6+ PERFORMER 21/12/2005151
A. Standard Image Files 152R5976816 RLM R6+ PERFORMER 21/12/2005
B. Maintenance of the Projector B. MAINTENANCE OF THE PROJECTOR B.1 Air Filters About maintaining the air filters It is recommended that you replace the air filters (located at the bottom of the projector) when you replace the lamp - or sooner, in dusty or dirty environment. In the latter case,check monthlyif replacement is required. A clogged filter reduces the air flow, and can lead to overheating and failure of the projector. Location of the air filters The air filters, in total 5 filters, are located into the bottom of the projector. The 2 exterior filters (4 & 5) are obstructed by the mounted stacking frame. To be able to remove these filters, loosen a few turn the frame screw (A) nearest the rear side of the projector. 1 2 3 4 5 A Image B-1 Location of air filters Replacement of the air filters 1. Press the lip (A) of the filter lock (2 for filters 1 to 3 and 1 for filter 4 & 5) to release and next, 2. Lift up front (B) of air filter and move forwards (C) to remove. (image B-2, image B-3) Tip:For the filters 4 & 5, when the lock is released, move the filter a little to the inside of the projector until the filter center clips are free, and next remove the filter to the outside. R5976816 RLM R6+ PERFORMER 21/12/2005 153
B. Maintenance of the Projector AB Image B-2 C Image B-3 Available kit All the 5 air filters are assembled to 1 kit, order numberR401045K 154 R5976816 RLM R6+ PERFORMER 21/12/2005
C. Specifications C. SPECIFICATIONS C.1 RLM R6+ Performer specifications Overview Light Output6000 ANSI Lumen 6500 Center lumen Resolution1400 x 1050 (native) Contrast ratio1600:1 (full field) Lamp2 x 250 W mercury Lamp warranty: 1000 hrs Ambient temperatureMax 40°C (104°F) Power consumption700 W Mains Voltage92-240 V WeightProjector: 25 kg (56 lbs) Frame: 5kg(11lbs) Dimensions (WxLxH)705 x 707,8 x 316,5 mm (27.8 x 27.9 x 12.5 inch) Sealed DLP™ coreStandard ScenergiXStandard horizontal and vertical electronic edge blending Picture-in-pictureUp to 4 sources simultaneously (2 data, 1 video and 1 SDI) Lens encodersOn zoom and focus (with TLD lenses) Input source compatibility1600 x 1200 (max. input) Fixed Inputs• 1x configurable 5 cable (BNC) • 1x composite Video (BNC) • 1x S-Video (4-pin DIN) • 1x analogue RGB (D15 Connector) • 1x SDI/HDSDI ( + loop through) •1xDVI Modular inputsNot available Throw RatioLens Throw ratio (on RLM R6+)TLD (HB) 0.8 0.75 TLD (HB) 1.6 - 2.0 1.45 - 1.85 TLD (HB) 2.0 - 2.8 1.85 - 2.55 TLD (HB) 2.8 - 5.0 2.55 - 4.55 TLD (HB) 5.0 - 8.0 4.55 - 7.3 Order InformationProjector body (without lens): R9010270 Spare dual lamp: R9852940 Lens Order NrTLD (HB) 0.8 R9842040 TLD (HB) 1.6 - 2.0 R9842060 TLD (HB) 2.0 - 2.8 R9842080 TLD (HB) 2.8 - 5.0 R9842100 TLD (HB) 5.0 - 8.0 R9842120 R5976816 RLM R6+ PERFORMER 21/12/2005155
C. Specifications 156R5976816 RLM R6+ PERFORMER 21/12/2005