19. Picture in Picture (PIP) • F1-F2-F4 and F5: changing the place of the PIP window in the projected image. Image 19-3 Position of the PIP window • F1-F2-F4 and F5: enlarging the PIP window when pressed a second time. Image 19-4 PIP window enlarged A Normal PIP window B Enlarged PIP window • F3: swapping the main source and the PIP source. Image 19-5 Image swapping R5976468 CINE VERSUM SYSTEM 03112003137
19. Picture in Picture (PIP) 138R5976468 CINE VERSUM SYSTEM 03112003
20. Cine VERSUM Master Settings & Info 20. CINE VERSUM MASTER SETTINGS & INFO Overview • Service Menu • Cine VERSUM Master Identification • Cine VERSUM Master Password • CineVERSUMMasterAddress Entering the Installation as well as the Service menu can be password protected. If this should be the case, trying to enter both menus is preceded by a pop up menu, requesting to enter password. 20.1 Service Menu How to enter the service menu 1. Select the INSTALLATION menu (see Loading a File, page 97). 2. Select itemSERVICEby rotating the jog dial on the Master or the↑or↓keys on the Remote Control. 3. Press the jog dial on the Master or the keyENTERon the Remote Control to confirm. The sub menu SERVICE appears on-screen and in the graphical display, including a list of available settings and info, specific for the Cine VERSUM Master. (menu 20-1) Service Identification Password IR Address 001 Common Address 000 Serial Communication I2C Diagnosis Back Menu 20-1 20.2 Cine VERSUM Master Identification How to select the Identification menu 1. Select itemIDENTIFICATIONby rotating the jog dial on the Master or the↑or↓keys on the Remote Control. 2. Press the selection wheel on the Master or the key ENTER on the Remote Control to confirm. The sub menu IDENTIFICATION appears on-screen and in the graphical display, including a list of general information about the Cine VERSUM Master. (menu 20-2) Identification Cine VERSUM Master IR Address: 1 Soft version: 2.0 Baudrate PC: 115200 Serial no: 0123456 Run time: 135h Link Time Jul 17 2002 11:51:28 Back Menu 20-2 R5976468 CINE VERSUM SYSTEM 03112003139
20. Cine VERSUM Master Settings & Info Explanation about the identification items The identification menu shows the general information of the Cine VERSUM Master status. • IR Address: typical address of the Cine VERSUM Master, to be used by the Remote Control to allow communication. • Soft Version: the loaded software version. This version number can be useful when calling for service assistance. • Baudrate PC: transfer speed for communication with an IBM PC (or compatible) or MAC. The baudrate must be the same as the baudrate of the connected computer. • Serial no: the fabrication number of the Cine VERSUM Master. This number can be useful when calling for service assistance. • Run Time: total run time since the first start up. • Link Time: below Link Time item, the creation date and time of the loaded software is shown. 20.3 Cine VERSUM Master Password How to activate the password protection To prevent user’s modify system set ups, entering the service and installation menu can be password protected. Follow next steps: 1. Select itemPASSWORDin the Service menu by rotating the jog dial on the Master or the↑or↓keys on the Remote Control. 2. Press the jog dial on the Master or the key ENTER on the Remote Control to confirm. The sub menu PASSWORD appears on-screen and in the graphical display, including the activation, Yes or No, of the password function and the possibility to change the password (4 digits). (menu 20-3) 3. Select item USE PASSWORD [No] by rotating the jog dial on the Master or the↑or↓keys on the Remote Control. The status of the password function is indicated between brackets. To change the status, continue with step 4. 4. Press the jog dial on the Master or the keyENTERon the Remote Control to change the status from Yes to No and back. Status [Yes]: entering the Installation as well as the service menu is password protected (after the Cine VERSUM System has been shut down and restarted). Status [No]: Installation and Service menu are accessible all the time. 5. Press the keyEXITon the Remote Control or select Back in the graphical display by rotating the jog dial on the Master followed by pressing the jog dial to confirm, to return. Password Use Password: [No] Modify Password Back Menu 20-3 140R5976468 CINE VERSUM SYSTEM 03112003
20. Cine VERSUM Master Settings & Info How to change the password 1. Select itemMODIFY PASSWORDby rotating the jog dial on the Master or the↑or↓keys on the Remote Control. 2. Press the jog dial on the Master or the keyENTERon the Remote Control to confirm. The sub menu NEW PASSWORD appears on-screen and in the graphical display, including the possibility to enter 4 digits, composing the new password. (menu 20-4) 3. Start with filling in the new name, (Always 4 characters) as follows: - Pressing the cursor keys←or→on the Remote Control or pressing the jog dial on the Master allows to select the character position (moving to the right). - Pressing the cursor keys↑or↓on the Remote Control or rotating the jog dial on the Master allows to change the character ( Numeric characters can be entered remotely with the numeric keys on the Remote Control). 4. When the last character of the new password has been entered, the system returns to preceding menu. 5. PressEXITon the Remote Control or select BACK in the graphical display menu, rotating the jog dial to select and pressing to confirm, to leave the menu mode. New Password Enter new value ---- Menu 20-4 20.4 Cine VERSUM Master Address Overview • About the Cine VERSUM Master Address • Cine VERSUM Master Address change • Selecting the Transmission Speed • Selecting the Interface standard (RS232/RS422) • RS422 data bus termination • Diagnosis 20.4.1 About the Cine VERSUM Master Address Common address The common address of the Cine VERSUM Master is 0 or 1, and is selectable in the Service menu. That means that all commands from the Remote Control, programmed with address 0 or 1, will be executed by the Cine VERSUM Master. Individual address In addition to the common address, an individual address can be set up in the Cine VERSUM Master, in case e.g. more units are located in the same location. In this way, the units can be addressed individually. The individual address can be set in the Service mode and the address number to be set depends on used control device (Remote Control or PC). • Addresses between 0 and 9: control device is the IR Remote Control 1 • Addresses between 0 and 255: control device is an IBM PC (or compatible), Apple, Mac, etc.. 1. . R5976468 CINE VERSUM SYSTEM 03112003141
20. Cine VERSUM Master Settings & Info Reading out the stored address in the Cine VERSUM Master • Point the front of the Remote Control at the IR sensor of the Cine VERSUM Master. • Press the address key on the Remote Control. Image 20-1 • A text box appears on-screen and in the graphical display on the Cine VERSUM Master indicating the stored address. MESSAGE IR Address: 1 Menu 20-5 20.4.2 Cine VERSUM Master Address change How to change the IR Address The IR address of the Cine VERSUM Master can be composed of3 numbers. Due to the limits of the Remote Control, values between 000 and 009 can be entered only. In case of PC control, values between 000 and 255 can be entered. 1. Select itemIR ADDRESSin the Service menu by rotating the jog dial on the Master or the↑or↓keys on theRemote Control. 2. Press the jog dial on the Master or the key ENTER on the Remote Control to confirm. The sub menu IR ADDRESS appears on-screen and in the graphical display, including the possibility to enter 3 digits, composing the new IR Address. (menu 20-6) 3. Press the cursor keys←or→on the Remote Control or press the jog dial on the Master to select the last digit. 4. Pressing the cursor keys↑or↓on the Remote Control or rotating the jog diall on the Master allows to change the character ( Numeric characters can be entered remotely with the numeric keys on the Remote Control). When the address number has been entered, system returns to service menu. 5. PressEXITon the Remote Control or selectBACKin the graphical display menu, rotating the jog dial to select and pressing to confirm, to exit the GUI. IR Address Enter New Value 001 Menu 20-6 142R5976468 CINE VERSUM SYSTEM 03112003
20. Cine VERSUM Master Settings & Info 20.4.3 Selecting the Transmission Speed How to set the transmission speed of the RS232 connection 1. Select itemSERIAL COMMUNICATIONin the Service menu by rotating the jog dial on the Master or the↑or↓keys on the Remote Control. 2. Press the jog dial on the Master or the key ENTER on the Remote Control to confirm. The sub menu SERIAL COMMUNICATION appears on-screen and in thegraphical display, including the possibility to set the Baudrate (transmission speed), the Interface standard RS232/RS422 and the RS422 termination. (menu 20-7) 3. Select itemBAUDRATEin the Serial Communication menu by rotating the jog dial on the Master or the↑or↓keys on the Remote Control. 4. Press the jog dial on the Master or theENTERkey on the Remote Control to change the Baudrate value between brackets. Note:Make sure that both the projector and the computer are set for the same Baud rate. Refer to the computer’s operation manual for instructions for setting the Baudrate. 5. PressEXITon the Remote Control or selectBACKin the graphical display menu, rotating the jog dial to select and pressing to confirm, to exit the GUI. Serial Communication Baudrate [115200] Interface: [RS232] Termination: [On] Back Menu 20-7 20.4.4 Selecting the Interface standard (RS232/RS422) About Data Transmission Standards have been developed to insure compatibility between units provided by different manufacturers, and to allow for reason- able success in transferring data over specified distances and/or data rates. RS232: Single-ended Data Transmission. The specification allows for data transmission from one transmitter to one receiver at relatively slow rates (up to 20K bits/second) and short distances (up to 50Ft.@ the maximum data rate). RS422: Differential Data Transmission: This standard was designed for greater distances and higher Baud rates. Data rates of up to 100K bits/second and distances up to 4000Ft. can be accommodated with RS422. How to set the interface standard Refer to the manual of the connected control unit about the data transmission standard to be set. 1. Select itemINTERFACEin the Serial Communication menu by rotating the jog dial on the Master or the↑or↓keys on the Remote Control (Selecting the Transmission Speed, page 143.). (menu 20-8) 2. Press the jog dial on the Master or theENTERkey on the Remote Control to change the Interface standard between brackets to RS232 or RS422. 3. PressEXITon the Remote Control or selectBACKin the graphical display menu, rotating the jog dial to select and pressing to confirm, to exit the GUI. Serial Communication Baudrate [115200] Interface: [RS232] Termination: [On] Back Menu 20-8 R5976468 CINE VERSUM SYSTEM 03112003143
20. Cine VERSUM Master Settings & Info 20.4.5 RS422 data bus termination How to terminate the RS422 data bus The last control unit on the RS422 data bus has to be terminated. 1. Select itemTERMINATIONin the Serial Communication menu by rotating the jog dial on the Master or the↑or↓keys on the Remote Control (Selecting the Transmission Speed, page 143.). (menu 20-9) 2. Press the jog dial on the Master or theENTERkeyontheRemoteControltosettheterminationtoON. 3. PressEXITon the Remote Control or selectBACKin the graphical display menu, rotating the jog dial to select and pressing to confirm, to exit the GUI. Serial Communication Baudrate [115200] Interface: [RS232] Termination: [On] Back Menu 20-9 20.4.6 Diagnosis How to interpret the diagnosis table The diagnosis menu includes a list of I2C controlled IC’s. Seven locations are mentioned in the table with the respective address (Hex code), followed by 3 plus signs. The significance of the plus signs is referred to the data communication between the I2C controlled IC’s, in order write – read – acknowledge. If one of the communication parameters is not available, then the respective plus sign is replaced by a minus sign. This info can be useful for the technician if you call for technical assistance. How to enter the diagnosis menu 1. Select itemI2C DIAGNOSISin the Service menu by rotating the jog dial on the Master or the↑or↓keys on the Remote Control. 2. Press the jog dial on the Master or the key ENTER on the Remote Control to confirm. The Diagnosis table appears on-screen and in the graphical display. (menu 20-10) 3. PressEXITon the Remote Control or selectBACKin the graphical display menu, rotating the jog dial to select and pressing to confirm, to exit the GUI. Diagnosis INPUT SELECT 74H +++ INPUT SELECT e0H +++ INPUT SELECT e2H +++ INPUT SELECT e4H +++ LOCAL CTRL__ ecH +++ PMP_________ 4aH +++ LCD DISPLAY_ 7aH +++ Back Menu 20-10 144R5976468 CINE VERSUM SYSTEM 03112003
21. Maintenance Indicators 21. MAINTENANCE INDICATORS Overview • Display Information • Display Diagnosis • ColorWheel IndexCine VERSUM 80 • Test Pattern 21.1 Display Information What info is displayed InstallationInput Slots File Service Display List Internal Pattern W hen no signal Source Transition OSD configuration Language Keystone Global Keystone:Yes Output: [Largest] Default Input Balance Back Display InfoSerial nr: 25416345 Type: CineVERSUM 50 Date: xx/xx/xx Temperature: 52 Runtime: 87h Software: 2.0 Firmware: Deserializer: 1 Interface: 01.01 Back Cine VERSUM r01 Display List1 CV50 On 2 CV120 On 3 CV80 On Back Main Menu/Installation/Display List/Display Settings/Display Info Display Settings Switch OFF Display Info Rename IR Address 009 Diagnosis Back Cine VERSUM 50 Display Settings Switch OFF Display Info Rename IR Address 009 Diagnosis CW Index Orientation Test patterns Back Cine VERSUM 80 Display Settings Switch OFF Display Info Rename IR Address 009 Diagnosis Orientation Test patterns Lens Lamp Back Cine VERSUM 120 Display Info Serial nr: 25416345 Type: CineVERSUM 80 Date: xx/xx/xx Temperature: 52 Runtime: 87h Software: 3.0 Firmware: Deserializer: 1 Formatter: 65 67 5 88 Lamp Type: 1 CW -ID:55 Runtime Lamp History Back Display Info Serial nr: 25416345 Type: CineVERSUM 120 Date: xx/xx/xx Temperature: 52 Runtime: 87h Software: 3.0 Firmware: Deserializer: 1 Formatters Lamp run time: 50 Lamp History Back Run TimesDisplay Total:197 h Lamp Total: 195 h 55: 6 h Colorwheel Total: 163 35-45: 3 h 45-50: 10 h 50-55: 21 h >55: 4 h Back Lamp History Current 2: - - - 3: - - - 4: - - - 5: - - - 6: - - - 7: - - - 8: - - - 9: - - - Add lamp Reset History Back New lamp serial Nr Enter new value _ _ _ _ _ _ _ _ Add Lamp Add lamp to history No Yes Reset History Are you sure? No Yes Lamp History Current 2: - - - 3: - - - 4: - - - 5: - - - 6: - - - 7: - - - 8: - - - 9: - - - Reset History Back Reset History Are you sure? No Yes Formatters Red Green Blue Back Formatter Info Config: Degamma: Main: Sequence: Back Image 21-1 Display info for Cine VERSUM Master – Cine VERSUM 80 and Cine VERSUM 120 Dependent on the selected display in the DISPLAY LIST menu, specific info is displayed on-screen and in the graphical display on the Cine VERSUM Master when selecting DISPLAY INFO in the Display settings menu. Explanation of the items Common for Cine VERSUM 50 – Cine VERSUM 80 and Cine VERSUM 120 Serial numberSerial number of the display Ty p eKind of the display DateDate of fabrication TemperatureInside temperature R5976468 CINE VERSUM SYSTEM 03112003145
21. Maintenance Indicators Common for Cine VERSUM 50 – Cine VERSUM 80 and Cine VERSUM 120 RuntimeTotal operation time of the display SoftwareInstalled software DeserializerConverts the serial data into parallel data For Cine VERSUM 80 only FormatterSerial number Lamp typeKind of the display Color Wheel IDColor wheel identification number RuntimeVia sub menu info about lamp run time and Color wheel run time, split up in ranges of temperature. . Lamp HistoryLamp history is kept up to date in the lamp history table. Via sub menu the possibility to add a new lamp and to reset the lamp history. When selecting ’Current’ in the lamp history table, lamp run time of the built-in lamp is shown. For Cine VERSUM 120 only FormattersVia sub menu info about the formatter for Red, Green and Blue. Lamp run timeTotal time of the lamp operation time. Lamp HistoryLamp history is kept up to date in the lamp history table. Via sub menu the possibility to reset the lamp history. When selecting ’Current’ in the lamp history table, lamp run time of the built-in lamp is shown. For Cine VERSUM 50 only InterfaceVersion number Due to rounding errors, the sum of hours in the Run times table is not always equal. 146R5976468 CINE VERSUM SYSTEM 03112003