APPENDIX F: Administration Error Messages
ERROR MESSAGE
AND DESCRIPTION
POSSIBLE SOLUTION
7037:inappropriate request
Direct Group Calling Delay
announcement groupAnnouncement (1 per system).
already exists
(Need a ZTN78 or TN742 CP port)
Go to MENU = 8 Search
ACTION = 1 DATA = 16
ACTION = 2 DATA = 255
ACTION = 3 DATA = 0
(hit c to continue)
Directed Night Service Delay
Announcement (2 per system)
(Need a ZTN78 or TN742 CP port)
Go to MENU = 8 Search
ACTION = 1 DATA = 16
ACTION = 2 DATA = 251 or 252...

Page 402

APPENDIX F: Administration Error Messages
ERROR MESSAGE
AND DESCRIPTIONPOSSIBLE SOLUTION
7047:incorrect PDCCan verify that the PDC is not in a
not in any DGC groupDGC group by:
Go to MENU = 8 Search
ACTION = 1 DATA = 6
ACTION = 2 DATA = PDC
(hit c to continue)
7048:incorrect PDC
Do a Search to find the DGC group
not in this DGC groupthe PDC is a member of.
Go to MENU = 8 Search
ACTION = 1 DATA = 6
ACTION = 2 DATA = PDC
(hit c to continue)
7049:
incorrect PDCIncorrect virtual facility access code.
must...

Page 403

APPENDIX F: Administration Error Messages
ERROR MESSAGE
AND DESCRIPTION
POSSIBLE SOLUTION
7054:out of spaceSystem speed digit pool is full.
no more room in digit
pool
7200:entry out of rangeInvalid TARGET value specification.
RS232 value out of rangeTarget value should be 1-4. See:
MENU = 10 (RS232)
7202:inappropriate requestACTION = 0 under MENU = 10
improper procedure(RS232) is invalid.
7203:incorrect entryMENU = 10 (RS232) ACTION = 1
logical channel out of
DATA = must be 1-4 (anything else
range
is...

Page 404

APPENDIX F: Administration Error Messages
ERROR MESSAGE
AND DESCRIPTIONPOSSIBLE SOLUTION
7401:incorrectMENU = 10 (RS-232) TARGET = 1
entryACTION = 1 DATA = 1 or 4
data must be 2 or 3(Reassign RS232 connector)
NOTE: Above statement
is wrong. data must be 1
or 4 only
8000:incorrect action numberA blank space is not acceptable.
can’t contain space
8001:incorrect action number3 digits must be entered for this
must be 3 digitsitem number.
8002:incorrect entryThe item ars activity area specified
does not...

Page 405

APPENDIX F: Administration Error Messages
ERROR MESSAGE
AND DESCRIPTION
POSSIBLE SOLUTION
8111:    incorrect entry           
trunk pool does not exist
Check the original trunk pool
entered against the ARS trunk pool
you are trying administer.
8112:    action number out of  
range
number must be 0-1Only 1 and 0 are valid entries for 
DDD overflow in ARS.
8113:    inappropriate request 
must install pool for this
route memberMust administer an ARS FAC
before trying to administer the FRL.
8201:...

Page 406

APPENDIX F: Administration Error Messages
ERROR MESSAGE
AND DESCRIPTIONPOSSIBLE SOLUTION
8402:entry out of rangeThe list number range is between
list reference can’t1-4.
exceed 4
8403:entry out of rangeThe pattern range is 1-8 or 0 for
must be 0-8 for removalremoval.
8404:incorrect entryThe list cannot exceed 4.
list reference can’t
exceed 4
8406:inappropriate requestAll information for the list was
all members of list weredisplayed. There is no more
displayedinformation in the list.
8407:incorrect...

Page 407

APPENDIX F: Administration Error Messages
ERROR MESSAGE
AND DESCRIPTIONPOSSIBLE SOLUTION
8418:entry out of rangeMENU = 11 (ARS) ACTlON = 501
list member must be 1DATA = 1 digit value, 1-8 range.
digit; value 1-8
8419:inappropriate requestAll members of the list have already
all members of list were
been displayed.
displayed
8420:
incorrect entryEntered number is not valid;
first digit can’t be O-1 (7recheck number.
digit max)
8421:at installed maxInstalled maximum reached for
-8 phone numberARS-HAC...

Page 408

APPENDIX F: Administration Error Messages
ERROR MESSAGE
AND DESCRIPTIONPOSSIBLE SOLUTION
8429:inappropriate requestThe telephone number cannot be
phone number exists-list
removed because it’s installed in list
33.
8430:inappropriate requestThe telephone number cannot be
phone number exists-list
removed because it’s installed in list
44.
8501:incorrect entryThe entered telephone number is
number can’t exceed 7not valid.
digits
8502:inappropriate requestThe telephone number is already in
phone number...

Page 409

APPENDIX F: Administration Error Messages
ERROR MESSAGE
AND DESCRIPTIONPOSSIBLE SOLUTION
8700:action number out ofMust enter pattern number first.
sequence
must enter pattern
number first
8701:incorrect action numberGo back and verify the action item
does not exist or used
taken.
improperly
8702:incorrect entry
Pattern number for other area
pattern number does notcodes exception numbers must be
existbetween 1-8.
See: MENU =11 (ARS) ACTION =
800
for more information.
8703:entry out of rangeMust be 8...

Page 410

APPENDIX F: Administration Error Messages
ERROR MESSAGE
AND DESCRIPTIONPOSSIBLE SOLUTION
9003:
inappropriate requestMENU =1 (Port) under Special
station to be linked notFeature port.
installedACTION = 1 DATA = 253
ACTION = 2 DATA = PDC or 0
In this case, the PDC is invalid or
does not exist.
9004:inappropriate requestTrying to administer an external
station already assigned
alert to a station that already has
external alertone.
9005:entry out of rangeMENU = 1 (PORT)
pre-night service rings(under special...