Page 351
APPENDIX E: Administration Codes and Data Table E-Q.Special Feature Port Type Codes This table shows data values associated with Action=1 on Table E-P. Feature TN742, ZTN78TN763 ZTN76ZTN77 TN748TN758 ZTN79 Tone Detector External Alert 1st Page Zone 2nd Page Zone 3rd Page Zone nth Page Zone DGC Delay Ann. Dial Dictation Music-On-Hold 2101 253 1301 1302 1303702† 702† 702† 702†802† 802† 802† 802† 255 201 2542201 1st N.S. Delay Ann. 2nd N.S. Delay Ann. 1st Selector Console 2nd Selector console251 252 1301...
Page 352
APPENDIX E: Administration Codes and Data Table E-R.Port Options PORTS, Station/Trunk/Special Port Circuit Board Options FOR QUALIFIED SYSTEMS TECHNICIANS ONLY (See Table E-S, Applicable Options ) ACTIONDESCRIPTIONDATA 32 Set CO disconnect time (in 20 msec[0-2540 msec; 500] increments) 33Set end-to-end signaling tone timing (in 20 msec increments) FOR TN742 AND ZTN78 ONLY:[20-2540 msec; 340] FOR ALL OTHER BOARDS:[0-2540 msec; 60] 34Set end-to-end signaling pause timing (in 20 msec increments) FOR TN742...
Page 353
APPENDIX E: Administration Codes and Data Table E-S.Applicable Options See WARNING for Table E-R. Also note that a bullet in a box on this table indicates that the default value for that action (shown in Table E-R) is applicable for this circuit board. No bullet indicates that the option is l Timing adjustable for internal calls only. † ACTION 35 (Hybrid Balance) defaults depend on board Trunk Ports are defaulted to 0 (Resistor/Capacitortype. termination), while Station Ports are defaulted to 1...
Page 354
APPENDIX E: Administration Table E-T. PDC Administration (Menu=2)Codes and Data ACTIONDESCRIPTION DATA 0 Move this station to a new port [CSSPP (new port assignment)] (moved-to port must be vacant) 1Display terminal type code[See Table E-C] 2-53All otherSee note below. 90 Assign/remove PD. Display ID[11 characters or less,” or ** to remove] Note: Action/data items administrable under PD. (Menu=2) are the same as those administrable under Port (Menu=1). (See Table E-B.) ‘ Table E-U. High Density Circuit...
Page 355
APPENDIX E: Administration Codes and Data Table E-V. System Administration (Menu=4) ACTIONDESCRIPTlON DATA 3Assign the number of rings before[Number of rings; 5] unanswered calls extended by Attendant return to the console (1 -31) 4Force DID calls to unassigned DID [1=Y/0=N] numbers to ring at Attendant Console 5Force calls to FPDCs that are not logged [1=Y/0=N] in anywhere to ring at the Attendant Console 6Assign the number of seconds before a[Number of seconds; camped-on call returns to the...
Page 356
APPENDIX E: Administration Codes and Data Table E-V. System Administration (Menu=4) (Contd) ACTIONDESCRIPTIONDATA 37 Specify type of dialing plan for Home [0=7-digit dialing; Area Code calls 1 = 10-digit dialing] 38Specify the number of digits used for[0=13digits,1=15 international dialingdigits] 40Provide call coverage ringing on internal [1=Y/0=N] calls 41Specify the number of rings before calls[0-31 ; 2] are sent to call coverage or call following calls return to their home station 50 Set time of...
Page 357
APPENDIX E: Administration Codes and Data Table E-V. System Administration (Menu=4) (Contd) ACTION DESCRIPTlON DATA 75Change administration password (up to 8 [8 characters or less”] printable characters, no spaces allowed, display always shows “?????????”) 76Change display ID for “PDC 0“ (up to 11[“ATTENDANT’] printable ASCII characters 77Change/removedisplay ID for [11 characters or less,” unassigned DID numbers (up to 11 or** to remove; printable ASCII characters “OUTSIDE”] 78Change/remove display...
Page 358
APPENDIX E: Administration Codes and Data Table E-V. System Administration (Menu=4) (Contd) ACTIONDESCRIPTION DATA 89 Should this SLAC attendant (specified in [1=Y/0=N] Action 88) receive a single-ring reminder whenever a new call enters the queue? 90Dual-position Switched Loop Attendant [0=neither, system: Which attendant should take on 1=1st Att., defaultmessagecenter-like 2=2nd Att.] characteristics? (See Table E-X) 91Switched Loop Attendant system: Enter[1-6, 8, 70-732; see call type code:Table E-W]...
Page 359
APPENDIX E: Administration Codes and Data Table E-V. System Administration (Menu=4) (Contd) ACTION DESCRIPTlONDATA 103For Callback Queuing: Enter the [0-1 20; 30] minimum time (in seconds) between callback retries for outgoing facilities 110For Remote Access: Enable barrier [1=Y/1=N] codes? 111Assign DID remote access digits[PD.; 0] 113Assign the remote Facility Restriction [0-3;3] Level (FRL) 114Assign the remote toll restriction class[1-4; 0 for none] 115Assign remote total outward restriction...
Page 360
APPENDIX E: Administration Codes and Data Table E-V. System Administration (Menu=4) (Contd) ACTIONDESCRIPTlON DATA I 130Assign RIMS barrier code digits (5 [5 through 15 digits or 0 through 15 digits; 0-9, *, # to remove; 98765] 140Sync. source” [0= Internal] [CSS of TN767=External 142Enable automatic sync. Source switching[1=enable/0=disable]* * In order to change the thing source, the DATA for Action 142 must be a”1 . November 1995E-41