Page 351

APPENDIX E: Administration Codes and Data
Table E-Q.Special Feature Port Type Codes
This table shows data values associated with Action=1 on Table E-P.
Feature
TN742,
ZTN78TN763 ZTN76ZTN77 TN748TN758 ZTN79
Tone Detector
External Alert
1st Page Zone
2nd Page Zone
3rd Page Zone
nth Page Zone
DGC Delay Ann.
Dial Dictation
Music-On-Hold
2101
253
1301
1302
1303702†
702†
702†
702†802†
802†
802†
802†
255
201
2542201
1st N.S. Delay
Ann.
2nd N.S. Delay
Ann.
1st Selector
Console
2nd Selector
console251
252
1301...

Page 352

APPENDIX E: Administration Codes and Data
Table E-R.Port Options
PORTS, Station/Trunk/Special Port Circuit Board Options
FOR QUALIFIED SYSTEMS TECHNICIANS ONLY
(See Table E-S,  Applicable Options  )
ACTIONDESCRIPTIONDATA
32
Set CO disconnect time (in 20 msec[0-2540 msec; 500]
increments)
33Set end-to-end signaling tone timing
(in 20 msec increments)
FOR TN742 AND ZTN78 ONLY:[20-2540 msec; 340]
FOR ALL OTHER BOARDS:[0-2540 msec; 60]
34Set end-to-end signaling pause timing
(in 20 msec increments)
FOR TN742...

Page 353

APPENDIX E: Administration Codes and Data
Table E-S.Applicable Options
See WARNING for Table E-R. Also note that a bullet in a box on this
table indicates that the default value for that action (shown in Table E-R)
is applicable for this circuit board. No bullet indicates that the option is
l Timing adjustable for internal calls only.
† ACTION 35 (Hybrid Balance) defaults depend on board
Trunk Ports are defaulted to 0 (Resistor/Capacitortype.
termination), while Station Ports are defaulted to 1...

Page 354

APPENDIX E: Administration
Table E-T. PDC Administration (Menu=2)Codes and Data
ACTIONDESCRIPTION
DATA
0
Move this station to a new port
[CSSPP (new port assignment)]
(moved-to port must be vacant)
1Display terminal type code[See Table E-C]
2-53All otherSee note below.
90
Assign/remove PD. Display ID[11 characters or less,” or ** to
remove]
Note: Action/data items administrable under PD. (Menu=2) are the same as those
administrable under Port (Menu=1). (See Table E-B.) ‘
Table E-U. High Density Circuit...

Page 355

APPENDIX E: Administration Codes and Data
Table E-V. System Administration (Menu=4)
ACTIONDESCRIPTlON
DATA
3Assign the number of rings before[Number of rings; 5]
unanswered calls extended by Attendant
return to the console (1 -31)
4Force DID calls to unassigned DID
[1=Y/0=N]
numbers to ring at Attendant Console
5Force calls to FPDCs that are not logged
[1=Y/0=N]
in anywhere to ring at the Attendant
Console
6Assign the number of seconds before a[Number of seconds;
camped-on call returns to the...

Page 356

APPENDIX E: Administration Codes and Data
Table E-V. System Administration (Menu=4) (Contd)
ACTIONDESCRIPTIONDATA
37
Specify type of dialing plan for Home
[0=7-digit dialing;
Area Code calls
1 = 10-digit dialing]
38Specify the number of digits used for[0=13digits,1=15
international dialingdigits]
40Provide call coverage ringing on internal
[1=Y/0=N]
calls
41Specify the number of rings before calls[0-31 ; 2]
are sent to call coverage or call following
calls return to their home station
50
Set time of...

Page 357

APPENDIX E: Administration Codes and Data
Table E-V. System Administration (Menu=4) (Contd)
ACTION
DESCRIPTlON
DATA
75Change administration password (up to 8
[8 characters or less”]
printable characters, no spaces allowed,
display always shows “?????????”)
76Change display ID for “PDC 0“ (up to 11[“ATTENDANT’]
printable ASCII characters
77Change/removedisplay ID
for [11 characters or less,”
unassigned DID numbers (up to 11
or** to remove;
printable ASCII characters
“OUTSIDE”]
78Change/remove
display...

Page 358

APPENDIX E: Administration Codes and Data
Table E-V. System Administration (Menu=4) (Contd)
ACTIONDESCRIPTION
DATA
89
Should this SLAC attendant (specified in
[1=Y/0=N]
Action 88) receive a single-ring reminder
whenever a new call enters the queue?
90Dual-position Switched Loop Attendant
[0=neither,
system: Which attendant should take on
1=1st Att.,
defaultmessagecenter-like
2=2nd Att.]
characteristics? (See Table E-X)
91Switched Loop Attendant system: Enter[1-6, 8, 70-732; see
call type code:Table E-W]...

Page 359

APPENDIX E: Administration Codes and Data
Table E-V. System Administration (Menu=4) (Contd)
ACTION
DESCRIPTlONDATA
103For Callback Queuing:
Enter the
[0-1 20; 30]
minimum time (in seconds) between
callback retries for outgoing facilities
110For Remote Access: Enable barrier
[1=Y/1=N]
codes?
111Assign DID remote access digits[PD.; 0]
113Assign the remote Facility Restriction
[0-3;3]
Level (FRL)
114Assign the remote toll restriction class[1-4; 0 for none]
115Assign remote total outward restriction...

Page 360

APPENDIX E: Administration Codes and Data
Table E-V. System Administration (Menu=4) (Contd)
 ACTIONDESCRIPTlON
DATA
I
130Assign RIMS barrier code digits (5 [5 through 15 digits or 0
through 15 digits; 0-9, *, #
to remove; 98765]
140Sync. source”
[0= Internal]
[CSS of
TN767=External
142Enable automatic sync. Source switching[1=enable/0=disable]*
* In order to change the thing source, the DATA for Action 142 must be a”1 .
November 1995E-41 