    Have a look at the manual ATT DEFINITY Communications System Generic 3 Pocket Reference Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 164 ATT manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							POWER UNITS
    POWER UNITS
    631DA1 Power Unit
    Provides +5 volt DC 60-amp power on the backplane on the control
    carrier and the port carriers.
    631DB1 Power Unit
    Provides -48 volt DC 8-amp and -5 volt 6-amp power on the back-
    planes of the carriers.
    644A1 Power Unit
    Provides +5 volt DC 60-amp power on the backplane on the control
    carrier and the port carriers of -48 volt DC powered cabinets.
    645B1 Power Unit
    Provides -48 volt DC 8-amp and -5 volt DC 6-amp power on the
    backplanes of the carriers of -48 volt DC powered cabinets.
    The control carrier contains one 645B Power Unit to power both the
    control and port circuit packs.
    WP-91153 L3 Power Supply
    Provides +5 volt DC power, -5 volt DC power, -48 volt DC power,
    +12 volt DC power, ringing voltage, and battery charge voltage for
    single-carrier cabinets.
    Provides circuit breakers and EMI filtering.
    86 
    						
    							POWER UNITS
    TN755B Power Unit
    Supports applications requiring neon message waiting lamps.
    676B Power Unit
    Provides +5 volt DC power, -5 volt DC power, -48 volt DC power,
    +12 volt DC power, and ringing voltage for -48 volt DC powered
    single-carrier cabinets.
    87 
    						
    							DUPLICATION OPTION
    DUPLICATION OPTION
    G3iV2, the Duplication Option provides:
    lA duplicated control carrier (multicarrier cabinet) or a
    duplicated control cabinet (single-carrier cabinet) that
    houses a second Switch Processing Element (SPE). The
    SPE includes the following:
    —  Processor Circuit Pack TN773
    —  Network Control Circuit Pack TN777B
    —  Packet Control Circuit Pack TN778 (G3V2)
    —  Memory Circuit Pack(s) TN770
    Power source to the fans from both the control carrier
    and duplicated control carrier.
    Duplicated Tone-Clock circuit packs TN768 that allow the
    system clock to be generated from either tone-clock cir-
    cuit pack. Note that if Stratum 3 Interface is required, the
    TN780 replaces the TN768.
    Duplicated lightguide cable between the Processor Port
    l
    l
    l
    Network (PPN) cabinet and the Expansion Port Network
    (EPN) cabinets. Duplicated 9823-type Iightwave tran-
    sceivers at both the PPN and EPN cabinets to terminate
    the fiber-optic links.
    For G3rV2, the Duplication Option provides the above options or a
    duplicated processor-only system, as follows:
    lTwo control carriers located in the PPN cabinet, which
    contain duplicate SPEs and tone-clock circuit packs
    lOne tone-clock circuit pack per EPN
    lDuplicate expansion interface circuit packs in the PPN
    (for DEFINITY G3rV2 with CSS)
    88 
    						
    							DUPLICATION OPTION
     l
     lPort networks interconnected by single cables
    Duplicate switch node circuit packs in the switch node
    carrier
    In a fully-duplicated G3rV2 system, there is also, in addition to the
    items mentioned for the G3iV2 system, a CSS.
    89 
    						
    							ENVIRONMENTAL REQUIREMENTS
    ENVIRONMENTAL REQUIREMENTS
    (Multicarrier Cabinet)
    CABINET
    Fully Loaded 5-Carrier (PPN or EPN)
    HEAT DISSIPATION
    8000 BTU/HR
    5000 BTU/HR
    AC POWER REQUIREMENTS
    120 volts
    60Hz
    208 volts (3-wire)
    60Hz
    208/240 volts (4-wire)
    60Hz
    DC POWER REQUIREMENTS800 Lbs
    70”x32”x28”
    Fully Loaded 5-Carrier
    Average 5-Carrier
    50 Amps MCC
    30 Amps MCC
    25 Amps MCC
    -48 volts
    75 Amps
    TEMPERATURE/ROOM HUMIDITY RANGE
    40° To 120°F.
    10% to 95% Relative Humidity at 84°F
    10% to 45% Relative Humidity at 110°F
    SHIPPING CARTON DIMENSIONS
    AND WEIGHT
    42” x 32” x 76”
    600 to 900 lbs
    (Single-Carrier Cabinet)
    CABINET
    Control - Basic and Duplicated
    130 Lbs
    20”x27”x22”
    Port or Expansion (4 cabinet stack)
    500 Lbs77’’x27”x22”
    90 
    						
    							ENVIRONMENTAL REQUIREMENTS
    Each Port or Expansion125 Lbs19”x27”x22”
    HEAT DISSIPATION
    6800 BTU/HRFully Loaded 4-Cabinet
    System (requirements
    are same for PPN and
    EPN)
    1700 BTU/HRAverage for a Single
    Cabinet
    AC POWER REQUIREMENTS
    120 volts 50-60Hz
    15 Amps1-Cabinet System
    120 volts 50-60Hz   Two 15 Amps or 20 Amps
    2-Cabinet System
    120 volts 50-60Hz   Three 15 Amps or 20 Amps
    3-Cabinet System
    and 15 Amps
    120 volts 50-60Hz   Two 15 Amps and 20 Amps
    4-Cabinet System
    or Two 20 Amps
    DC POWER REQUIREMENTS
    -48 volts 25 Amps Power Source is required for each cabinet
    TEMPERATURE/ROOM HUMIDITY RANGE
    (Same as multicarrier cabinet)
    SHIPPING CARTON DIMENSIONS
    AND WEIGHT (Shipped as a single cabinet)
    32” x 29.5” x 36”180 to 200 lbs
    91 
    						
    							MAXIMUM CABLING DISTANCES
    MAXIMUM CABLING DISTANCES
    Equipment24-Gauge Wire26-Gauge Wire
    (0.5106 mm)
    (0.4049 mm)
    FeetMetersFeetMeters
    Attendant console (301A)
    2400732
    1500457
    Enhanced attendant console (302A)
    With selector console
    Phantom powered
    Locally powered
    Without selector console
    Phantom powered
    Locally powered800
    5000
    1400
    5000244
    1524
    427
    1524500
    3400
    900
    3400
    2200152
    1037
    274
    1037
    510D or 515 terminals
    3000914
    670
    513, 610 BCT, or 615 MT, 4410 or 4425
    terminals ( see also “data module” or
    “EIA interface”) 50-ft.  maximum
    distance from terminal or BCT to module
    or ADU----
    Data modules:
    Z702AL1-DSU data module base
    Z703AL1-DSU data module base
    7404D data module
    DTDM
    MPDM
    MTDM
    3270 data module5000
    5000
    5000
    3400
    5000
    5000
    50001524
    1524
    1524
    1037
    1524
    1524
    15244000
    4000
    4000
    2200
    4000
    4000
    40001219
    1219
    1219
    670
    1219
    12191219
    92 
    						
    							MAXIMUM CABLING DISTANCES
    Equipment
    EIA interface (data line circuit
    pack and ADU):
    19.2 kbps
    9.6 kbps
    4.8 kbps
    2.4 kbps
    1.2 kbps
    0.3 kbps
    Voice terminals:
    Analog
    8-port circuit pack (TN742, TN769), on-premises or
    out-of-building — same premises (notes 1 and 2)
    500- or 2500- type (note 3)
    7100 series
    16-port circuit pack (TN746), on-premises only
    — no out-of-building or bridging (note 1)
    AT&T 500 or 2500 type terminals without adjuncts
    16-port circuit pack (TN746B), on-premises or
    out-of-building — same premises (notes 1 and 2)
    500- or 2500-type (note 3)
    7100 series
    Hybrid (TN762)
    7300 series (without aux power)
    7300 Series (with aux power)
    Digital (TN754B) (Note 4)
    7400D series
    Phantom powered
    Locally powered
    Digital (TN754)
    7400D series
    On-premises-only terminals
    Out-of-bldg. same premises terminals (note 4)24-Gauge Wire
    (0.5106 mm)
    Feet
    2000
    5000
    7000
    12000
    20000
    40000
    20000
    15200
    3100
    20000
    15200
    1000
    2000
    3400
    5000
    3000
    2400Meters
    610
    1524
    2130
    3654
    610012200
    6100
    4633
    945
    6100
    4633
    305
    610
    1037
    1524
    914
    73226-Gauge Wire
    (0.4049 mm)
    Feet
    2000
    4000
    6000
    10000
    16000
    30000
    13000
    10000
    2000
    13000
    10000
    750
    2000
    2200
    4000
    2200
    1300Meters
    610
    1219
    1827
    3050
    4875
    9150
    3962
    3050
    610
    3962
    3050
    229
    610
    670
    1219
    670
    396
    93 
    						
    							MAXIMUM CABLING DISTANCES
    Equipment
    Meters
    ISDN (TN556) (note 5)
    7500 series (point-to-point)
    Termination resistor (3 feet)
    Termination resistor (250 feet)
    8503 Set
    MET sets (TN735)24-Gauge Wire
    (0.5106 mm)
    Feet
    1900
    1600
    1600
    1000579
    488
    487
    30526-Gauge Wire
    (0.4049 mm)
    Feet
    1600
    1300
    1330
    650
    Meters
    488
    396
    405
    198
    Notes:
    1.
    2.
    3.
    An out-of-building, same-premises, analog terminal instal-
    lation requires a carbon block, gas tube, or equivalent
    solid state device at each end of the interbuilding cable.
    Only AT&T 500- or 2500-type terminals can be used off-
    premises to a CO.
    Point-to-point connections and terminals are within 33
    feet of the jack.
    94 
    						
    							MAXIMUM CABLING DISTANCES
    PPN CABINET TO EPN CABINET
    MAXIMUM CABLING DISTANCES
    The maximum length of the fiber-optic cable between the PPN
    cabinet and the EPN cabinet is approximately 7.6 km (25,000 feet)
    depending on installation requirements. The requirements that
    determine the maximum fiber link distance for an installation are:
    l
    l
    l
    l
    lThe mean loss and the length of the outside plant fiber
    cable
    The mean loss and the length of fiber cable shipped with
    the cabinet (including any fiber riser cable)
    The mean loss of a lightguide cable connector ST® and
    the number of ST connections
    The mean loss of a rotary mechanical splice and the
    number of splices
    Higher order mode loss
    The Premises Service Consultant (PSC) must always be con-
    sulted in the fiber link design for any remote EPN configura-
    tion.
    The speed of the fiber optic cable link between the PPN cabinet and
    the EPN cabinet is 32.788 Mb per second.
    95 
    						