Have a look at the manual ATT DEFINITY Communications System Generic 3 Pocket Reference Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 164 ATT manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
POWER UNITS POWER UNITS 631DA1 Power Unit Provides +5 volt DC 60-amp power on the backplane on the control carrier and the port carriers. 631DB1 Power Unit Provides -48 volt DC 8-amp and -5 volt 6-amp power on the back- planes of the carriers. 644A1 Power Unit Provides +5 volt DC 60-amp power on the backplane on the control carrier and the port carriers of -48 volt DC powered cabinets. 645B1 Power Unit Provides -48 volt DC 8-amp and -5 volt DC 6-amp power on the backplanes of the carriers of -48 volt DC powered cabinets. The control carrier contains one 645B Power Unit to power both the control and port circuit packs. WP-91153 L3 Power Supply Provides +5 volt DC power, -5 volt DC power, -48 volt DC power, +12 volt DC power, ringing voltage, and battery charge voltage for single-carrier cabinets. Provides circuit breakers and EMI filtering. 86
POWER UNITS TN755B Power Unit Supports applications requiring neon message waiting lamps. 676B Power Unit Provides +5 volt DC power, -5 volt DC power, -48 volt DC power, +12 volt DC power, and ringing voltage for -48 volt DC powered single-carrier cabinets. 87
DUPLICATION OPTION DUPLICATION OPTION G3iV2, the Duplication Option provides: lA duplicated control carrier (multicarrier cabinet) or a duplicated control cabinet (single-carrier cabinet) that houses a second Switch Processing Element (SPE). The SPE includes the following: — Processor Circuit Pack TN773 — Network Control Circuit Pack TN777B — Packet Control Circuit Pack TN778 (G3V2) — Memory Circuit Pack(s) TN770 Power source to the fans from both the control carrier and duplicated control carrier. Duplicated Tone-Clock circuit packs TN768 that allow the system clock to be generated from either tone-clock cir- cuit pack. Note that if Stratum 3 Interface is required, the TN780 replaces the TN768. Duplicated lightguide cable between the Processor Port l l l Network (PPN) cabinet and the Expansion Port Network (EPN) cabinets. Duplicated 9823-type Iightwave tran- sceivers at both the PPN and EPN cabinets to terminate the fiber-optic links. For G3rV2, the Duplication Option provides the above options or a duplicated processor-only system, as follows: lTwo control carriers located in the PPN cabinet, which contain duplicate SPEs and tone-clock circuit packs lOne tone-clock circuit pack per EPN lDuplicate expansion interface circuit packs in the PPN (for DEFINITY G3rV2 with CSS) 88
DUPLICATION OPTION l lPort networks interconnected by single cables Duplicate switch node circuit packs in the switch node carrier In a fully-duplicated G3rV2 system, there is also, in addition to the items mentioned for the G3iV2 system, a CSS. 89
ENVIRONMENTAL REQUIREMENTS ENVIRONMENTAL REQUIREMENTS (Multicarrier Cabinet) CABINET Fully Loaded 5-Carrier (PPN or EPN) HEAT DISSIPATION 8000 BTU/HR 5000 BTU/HR AC POWER REQUIREMENTS 120 volts 60Hz 208 volts (3-wire) 60Hz 208/240 volts (4-wire) 60Hz DC POWER REQUIREMENTS800 Lbs 70”x32”x28” Fully Loaded 5-Carrier Average 5-Carrier 50 Amps MCC 30 Amps MCC 25 Amps MCC -48 volts 75 Amps TEMPERATURE/ROOM HUMIDITY RANGE 40° To 120°F. 10% to 95% Relative Humidity at 84°F 10% to 45% Relative Humidity at 110°F SHIPPING CARTON DIMENSIONS AND WEIGHT 42” x 32” x 76” 600 to 900 lbs (Single-Carrier Cabinet) CABINET Control - Basic and Duplicated 130 Lbs 20”x27”x22” Port or Expansion (4 cabinet stack) 500 Lbs77’’x27”x22” 90
ENVIRONMENTAL REQUIREMENTS Each Port or Expansion125 Lbs19”x27”x22” HEAT DISSIPATION 6800 BTU/HRFully Loaded 4-Cabinet System (requirements are same for PPN and EPN) 1700 BTU/HRAverage for a Single Cabinet AC POWER REQUIREMENTS 120 volts 50-60Hz 15 Amps1-Cabinet System 120 volts 50-60Hz Two 15 Amps or 20 Amps 2-Cabinet System 120 volts 50-60Hz Three 15 Amps or 20 Amps 3-Cabinet System and 15 Amps 120 volts 50-60Hz Two 15 Amps and 20 Amps 4-Cabinet System or Two 20 Amps DC POWER REQUIREMENTS -48 volts 25 Amps Power Source is required for each cabinet TEMPERATURE/ROOM HUMIDITY RANGE (Same as multicarrier cabinet) SHIPPING CARTON DIMENSIONS AND WEIGHT (Shipped as a single cabinet) 32” x 29.5” x 36”180 to 200 lbs 91
MAXIMUM CABLING DISTANCES MAXIMUM CABLING DISTANCES Equipment24-Gauge Wire26-Gauge Wire (0.5106 mm) (0.4049 mm) FeetMetersFeetMeters Attendant console (301A) 2400732 1500457 Enhanced attendant console (302A) With selector console Phantom powered Locally powered Without selector console Phantom powered Locally powered800 5000 1400 5000244 1524 427 1524500 3400 900 3400 2200152 1037 274 1037 510D or 515 terminals 3000914 670 513, 610 BCT, or 615 MT, 4410 or 4425 terminals ( see also “data module” or “EIA interface”) 50-ft. maximum distance from terminal or BCT to module or ADU---- Data modules: Z702AL1-DSU data module base Z703AL1-DSU data module base 7404D data module DTDM MPDM MTDM 3270 data module5000 5000 5000 3400 5000 5000 50001524 1524 1524 1037 1524 1524 15244000 4000 4000 2200 4000 4000 40001219 1219 1219 670 1219 12191219 92
MAXIMUM CABLING DISTANCES Equipment EIA interface (data line circuit pack and ADU): 19.2 kbps 9.6 kbps 4.8 kbps 2.4 kbps 1.2 kbps 0.3 kbps Voice terminals: Analog 8-port circuit pack (TN742, TN769), on-premises or out-of-building — same premises (notes 1 and 2) 500- or 2500- type (note 3) 7100 series 16-port circuit pack (TN746), on-premises only — no out-of-building or bridging (note 1) AT&T 500 or 2500 type terminals without adjuncts 16-port circuit pack (TN746B), on-premises or out-of-building — same premises (notes 1 and 2) 500- or 2500-type (note 3) 7100 series Hybrid (TN762) 7300 series (without aux power) 7300 Series (with aux power) Digital (TN754B) (Note 4) 7400D series Phantom powered Locally powered Digital (TN754) 7400D series On-premises-only terminals Out-of-bldg. same premises terminals (note 4)24-Gauge Wire (0.5106 mm) Feet 2000 5000 7000 12000 20000 40000 20000 15200 3100 20000 15200 1000 2000 3400 5000 3000 2400Meters 610 1524 2130 3654 610012200 6100 4633 945 6100 4633 305 610 1037 1524 914 73226-Gauge Wire (0.4049 mm) Feet 2000 4000 6000 10000 16000 30000 13000 10000 2000 13000 10000 750 2000 2200 4000 2200 1300Meters 610 1219 1827 3050 4875 9150 3962 3050 610 3962 3050 229 610 670 1219 670 396 93
MAXIMUM CABLING DISTANCES Equipment Meters ISDN (TN556) (note 5) 7500 series (point-to-point) Termination resistor (3 feet) Termination resistor (250 feet) 8503 Set MET sets (TN735)24-Gauge Wire (0.5106 mm) Feet 1900 1600 1600 1000579 488 487 30526-Gauge Wire (0.4049 mm) Feet 1600 1300 1330 650 Meters 488 396 405 198 Notes: 1. 2. 3. An out-of-building, same-premises, analog terminal instal- lation requires a carbon block, gas tube, or equivalent solid state device at each end of the interbuilding cable. Only AT&T 500- or 2500-type terminals can be used off- premises to a CO. Point-to-point connections and terminals are within 33 feet of the jack. 94
MAXIMUM CABLING DISTANCES PPN CABINET TO EPN CABINET MAXIMUM CABLING DISTANCES The maximum length of the fiber-optic cable between the PPN cabinet and the EPN cabinet is approximately 7.6 km (25,000 feet) depending on installation requirements. The requirements that determine the maximum fiber link distance for an installation are: l l l l lThe mean loss and the length of the outside plant fiber cable The mean loss and the length of fiber cable shipped with the cabinet (including any fiber riser cable) The mean loss of a lightguide cable connector ST® and the number of ST connections The mean loss of a rotary mechanical splice and the number of splices Higher order mode loss The Premises Service Consultant (PSC) must always be con- sulted in the fiber link design for any remote EPN configura- tion. The speed of the fiber optic cable link between the PPN cabinet and the EPN cabinet is 32.788 Mb per second. 95