    Have a look at the manual ATT DEFINITY Communications System Generic 3 Pocket Reference Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 164 ATT manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							SYSTEM PARAMETERS
    ITEM
    G3iV1.1-G3vsV2G3sV2G3iV2-G3rV2286ABP/PBPABP/PBP
    386
    Total Slots (27)15365125121,53611,264
    Time Slots for Voice & Data (28)14494834831,44910,604
    Time Slots per Port Network
    512512512512512
    Tone Classifiers
    Call Classifier Boards10NA/10NA/101050
    Call Progress/Touch Tone80NA/80NA/8080400
    Receivers
    Tone Detector Boards
    20
    10
    202050
    General Purpose Tone40204040100
    Detectors
    Touch-Tone Receivers
    80808080200
    Prompting TTR Queue Size80NA/80NA/808080
    TTR Queue Size4
    4444
    Trunks
    DS1 Circuit Packs3088
    30166
    Queue Slots for Trunks19832/6432/64198
    1,332
    PRI Interfaces via PI (29)8NA/4
    NA/4
    8NA
    PRI Interfaces via PKTINTNANANANA166
    PRI Temporary Signaling
    Connections
    27.512 time slots per port network.
    28.483 time slots for Voice and Data per port network. Even
    though an EPN is supported in G3sV2, giving a total of
    two port networks, G3sV2 is engineered to support only
    180 Simultaneous Circuit-Switched Calls.
    29.
    Only one PI board is supported in G3vs/G3s (both MCC
    and SCC), and therefore a total of four physical links,
    used for BX.25 or PRI, are available.
    In G3i, two PI boards can be supported in the MCC, and
    therefore a total of eight physical links (used for BX.25 or
    PRI) are available.
    46 
    						
    							SYSTEM PARAMETERS
    Since the SCC can only support one PI board, a total of
    four physical links (used for BX.25 or PRI) are available in
    the SCC 286 and Medium configurations.
    47 
    						
    							SYSTEM PARAMETERS
    286
    ITEMG3iV1.1-G3vsV2G3sV2G3iV2-G3rV2ABP/PBPABP/PBP386
    TSCs in System
    656NA/164
    NA/164
    6564,256
    Call Associated TSCs400NA/100NA/1004,000
    Non Call Associated TSCs
    256NA/64NA/64256
    Administered TSCs128NA/32NA/32128128
    Ringback Queue Slots19832/64
    32/641981,332
    Total PRI Interfaces (30)
    8NA/4NA/48166
    Trunk Groups Hourly2525252575
    Measurements
    Trunk Groups in the System9916/3216/32
    99
    Trunk Members in a Trunk Group9950/9950/99
    99255
    Trunks in System (incl Rem40050/10050/1004,000
    Access) (32)
    With Hospitality Parameter50NA/50NA/50
    5050
    Reduction
    Measured Trunks in System40050/10050/1004000
    Voice Terminals
    Associated Data Modules80075
    757,500
    (e.g.,DTDMs)
    BRI Stations (31)1,000
    NA501,0007,000
    Digital Stations (32)1,600
    2,40025,000
    Stations (32)1,6002002,40025,000
    Station Button Capacity410.468.4
    68.4547.25,260
    (K units) (33)400
    256
    666
    400
    400
    800
    200200
    200
    30.   All digital stations can be display stations.
    31.  All BRI stations can be display stations.
    32.G3vs has the same software capacities for sta-
    tions and trunks as does G3s. However, these
    software capacities are limited
    by the cabinet hardware. A typical switch
    would probably have 20 to 50 stations with 10
    to 20 trunks. Station capacities can be
    reached only by administration without
    hardware (AWOH). This includes extensions
    administered without associated hardware.
    48 
    						
    							SYSTEM PARAMETERS
    33.
    In G3, “Station Button Capacity (units)
    ‘replaces’ Maximum Button Modules.”
    The following examples show how these units
    can be used. The assumption is that only three
    call appearances are assigned to the sets
    (except analog sets which have no call appear-
    ances).
    Analog sets (for example, 7104A):
    G3r, 76 units; all other releases, 62
    units.
    Digital sets with 10 buttons (for
    example, 7403D): G3r, 124 units; all
    other releases, 102 units.
    Digital sets with 34 buttons, without
    display (for example, 7405D): 3r, 412
    units; all other releases, 342 units.
    Digital sets with 34 buttons, with 
    display (for example, 7405D): G3r,
    568 units; all other releases, 472
    units.
    7406D Digital sets with display: G3r,
    412 units; all other releases, 342
    units.
    BRI sets with 17 buttons, with
    display (for example, 7506D): 
    G3r, 304
    units; all other releases, 250 units.
    The station button capacity can support all sta-
    tions equipped as 7406D digital sets with
    display.
    For example, a total of 342 * 1200 = 410.4K
    units for the 
    G3iV1.1-286.
    49 
    						
    							SYSTEM CABINET CONFIGURATIONS
    SYSTEM CABINET
    CONFIGURATIONS
    A G3iV2 system configuration can consist of a PPN alone or a PPN
    with up to two EPNs. A G3rV2 system can be configured with up to
    21 EPNs. The system is available in a multicarrier cabinet (MCC)
    configuration, a single-carrier cabinet (SCC) configuration, or a
    combination of MCC(s) and SCC(s). In a system with two EPNs,
    one EPN can be an SCC and one an MCC. The system can be
    configured with or without duplication. G3sV2 and G3vsV2 only
    support one SCC stack and do not support duplication.
    The configurations for systems without duplication are as follows:
    l
    l
    l
    l
    l
    lMCC PPN (stand-alone)
    MCC PPN with MCC EPN
    MCC PPN with maximum of 2 MCC EPNs (G3iV2 only)
    or maximum of 21 MCC EPNs (G3rV2 only)
    MCC PPN with maximum of one MCC EPN and one
    SCC EPN (G3iV2 only) or up to 21 SCC and MCC EPNs
    mixed (G3rV2 only)
    MCC PPN with SCC EPN
    MCC PPN with maximum of 2 SCC EPNs (G3iV2 only) or
    maximum of 21 SCC EPNs (G3rV2 only)
    SCC PPN (stand-alone) - G3sV2, G3vsV2, and G3iV2
    only
    SCC PPN with MCC EPN - G3iV2 only
    SCC PPN with MCC EPNs (max. of 2 EPNs) - G3iV2
    only
    SCC PPN with MCC EPN and SCC EPN (max. of 2
    EPNs) - G3iV2 only
    l
    l
    l
    l
    50 
    						
    							SYSTEM CABINET CONFIGURATIONS
    SCC PPN with SCC EPN - G3iV2
    SCC PPN with SCC EPNs (max. of 2 EPNs) - G3iV2 onlyl
    l
    Configurations for a system with duplication are basically the same
    as for a system without duplication, except a duplicated control car-
    rier replaces a port carrier in the EPN of a system with duplication.
    G3sV2 and G3vsV2 systems cannot be duplicated.
    51 
    						
    							CIRCUIT PACKS
    CIRCUIT PACKS
    The following table lists the circuit packs for the G3sV2 and G3iV2.
    CodeNameType
    None
    DEFINITY AUDIX SystemPort
    631DA1Power Unit (AC)Power
    631DB1Power Unit (AC)
    Power
    644A1Power Unit (DC)
    Power
    645B1Power Unit (DC)Power
    676BPower Supply (DC)
    Power
    982LSCurrent LimiterPower
    CFY1BCurrent Limiter
    Power
    CPP1Expansion MemoryControl
    TN413Digital LinePort
    TN417Auxiliary TrunkPort
    TN419BTone-clock
    Service
    TN420B/CTone DetectorService
    TN429DiOD TrunkPort
    TN433Speech SynthesizerService
    TN436BDID TrunkPort
    TN437Tie Trunk
    Port
    TN438BCO TrunkPort
    TN439Tie TrunkPort
    TN447CO Trunk
    Port
    TN457Speech Synthesizer
    52 
    						
    							CIRCUIT PACKS
    CodeNameType
    TN458Tie TrunkPort
    TN459BDID TrunkPort
    TN464CDS1/E1 InterfacePort
    TN464DDS1/E1Port
    TN465CO TrunkPort
    TN467, TN468B
    Analog LinePort
    TN479
    Analog LinePort
    TN497Tie TrunkPort
    TN556ISDN BRI LinePort
    TN566BISDN BRI Line (A-Law)Port
    TN570
    Expansion Interface (EI)Port
    TN725B
    Speech SynthesizerService
    TN726B
    Data LinePort
    TN735MET Line
    Port 
    TN742Analog LinePort
    TN744
    Call ClassifierService
    TN746, BAnalog LinePort
    TN747B
    CO TrunkPort
    TN748C/DTone DetectorService
    TN750, BAnnouncement
    Service
    TN753
    DID TrunkPort
    TN754, BDigital LinePort
    TN755BPower Unit, NeonPower
    TN756Tone DetectorService
    TN758Pooled ModemPort
    53 
    						
    							CIRCUIT PACKS
    CodeName
    Type
    TN760DTie Trunk Port
    TN762BHybrid LinePort
    TN763B, C, D
    Auxiliary TrunkPort
    TN765Processor Interface
    Control
    TN767BDS1/E1 InterfacePort
    TN768Tone-clock
    Service
    TN769Analog LinePort
    TN771DMaintenance/Test
    Service
    TN772Duplication InterfaceControl
    TN775BMaintenanceService
    TN776Expansion Interface (EI)Port
    TN777BNetwork Control
    Control
    TN778Packet Control
    Control
    TN780Tone-clockService
    TN786BProcessorControl
    TN2135Analog LinePort
    TN2136Digital LinePort
    TN2138CO TrunkPort
    TN2139DID TrunkPort
    TN2140Tie Trunk
    Port
    TN2144Analog LinePort
    TN2146DID TrunkPort
    TN2147CO TrunkPort
    TN2149Analog LinePort
    WP-91153Power Supply (AC)Power
    54 
    						
    							CIRCUIT PACKS
    The following table lists the circuit packs for the G3rV2.
    CodeName
    NoneDEFINITY AUDIX SystemType
    Port
    Power
    631DA1Power Unit (AC)
    631DB1Power Unit (AC)Power
    644A1  Power Unit (DC)Power
    645B1Power Unit (DC)Power
    676BPower Supply (DC)Power
    Power
    CFY1BCurrent Limiter
    TN464C
    DS1/E1 InterfacePort
    TN464D
    DS1/E1Port
    TN553
    Packet Data LinePort
    Port
    TN556
    ISDN BRI Line
    TN570
    Expansion Interface (EI)Port
    Service
    TN572SN Clock
    TN573
    SN InterfaceControl
    Port
    Port
    Port
    Service
    Port
    Port
    Port
    Service TN574
    DS1 Converter
    TN577Packet Gateway
    TN722BDS1/E1 Tie Trunk
    TN725BSpeech Synthesizer
    TN726BData Line
    TN735MET Line
    TN742Analog Line
    TN744Call Classifier
    55 
    						
    All ATT manuals Comments (0)