    Have a look at the manual ATT DEFINITY Communications System Generic 3 Pocket Reference Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 164 ATT manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							SYSTEM PARAMETERS
    ITEM
    G3iV1.1-G3vsV2G3sV2G3iV2-G3rV2286ABP/PBPABP/PBP386
    Remote Access Barrier Codes1010101010
    CDR Forced Entry Account1NA/1NA/111
    Code List
    Toll Call List
    1
    111
    1
    Unresticted/Allowed Call Lists1010101010
    Total Call List Entries
    1,0001,0001,0001,0001,000
    Automatic Callback Calls16020202401,500
    Automatic Wakeup
    Simultaneous Display Requests1010101030
    Wakeup Requests per System1,200
    200
    2002,40015,000
    Wakeup Request per Extension
    1
    1111
    Wakeup Requests per 15 min300150150450950
    Interval
    Basic CMS
    Daily Summary Reports7
    777
    7
    Measured Agents2007575200200
    Measured Splits
    9912/24
    12/249999
    Measured Trunk Groups
    3216/3216/323232
    Measured VDNs
    99NA/24NA/2499512
    Reporting Periods (30 or 60 min)2525252525
    Number of Terminals User IDs
    5
    5558
    Cabinets
    EPN
    MCC(8)2NANA221
    SCC(8)8NANA880
    Small (Upgrades only)(9)2NANA220
    8.
    9.The EPNs in G3r can be DS1-remote EPNs.
    Small systems refer to the two-carrier cabinet systems
    that are no longer sold to new customers.
    36 
    						
    							SYSTEM PARAMETERS
    ITEM
    G3iV1.1-G3vsV2G3sV2G3rV2286ABP/PBP
    ABP/PBP
    Inter-Port Network Connectivity
    Port Networks31
    13
    22
    Max No. of Port Networks/Cabinet1111
    2
    Switch Node Carriers (Simplex)NANANANA2
    Switch Node Carriers (Duplex)NANANANA4
    DS1 Converter Complex (Simplex)NANANANA
    20
    DS1 Converter Complex (Duplex)NANANANA40
    PPN
    MCC (10)1NANA11
    SCC/ESCC4NA44NA
    CSCC
    NA1NANANA
    Remote Modules
    Remote Port Network
    2NANA221
    Call Appearances
    Bridged Images/Appearance777715
    Call Appearances/Station(11)
    54
    54545454
    Max. Appearances per Ext.10
    10101010
    Min. Appearances per Ext.22222
    Total Bridged Appearances
    1,600
    2002002,400
    25,000
    Max.Simultaneous Off-Hook
    55555
    per Call (12)
    Call Coverage
    Coverage Answer Groups (CAG)200
    3030200750
    G3iV2-
    386
    10.MCC includes Medium Cabinet.
    11.
    The number of call appearances is the sum of primary
    and bridged appearances; at most 10 can be primary. A
    maximum of 54 administrable
    buttons are supported for the 7434D terminal—34 buttons
    in the basic terminal and an additional 20 buttons in the
    coverage module.
    Does not apply to conferencing. 12.
    37 
    						
    							SYSTEM PARAMETERS
    ITEMG3iV1.1-G3vsV2G3sV2G3iV2-G3rV2286
    ABP/PBPABP/PBP
    386
    Coverage Paths
    6001501506007,500
    With Hospitality Parameter Reduction
    5NA/5NA/555
    Coverage Paths Incl. in Call Covg.Report100100100100100
    Coverage Path per Station (13)4
    4
    44
    4
    Coverage Points in a Path33
    333
    Max Users/Coverage Path(14)
    29005003,50036,065
    Members per CAG
    888
    88
    Call Detail Recording
    CDRU Trackable Extensions1,6002002,40025,000
    Intra-switch Call Trackable Extensions100100100100500
    No. of CDRUs/System (15)
    11
    11
    1
    Call Forwarding (Follow-me)
    Call Forwarded Digits (off-net)1616
    16
    1616
    Call Forwarded Numbers
    1,600
    2002002,40025,000
    Call Park
    Attnd.Grp. Common Shared Exten.Nos.1010101080
    No. of Parked Calls723180
    180
    7235,302
    Call Pickup Groups
    Call Pickup Members/Group5050
    505050
    Call Pickup Members/System1,6002002002,40025,000
    No. of Groups
    800
    100100
    5,000
    With Hosptality Parameter Reduction
    5NA/5
    NA/55
    500
    200
    800
    5
    13.Only available with ABP when AT&T Voice Power adjunct
    (AUDIX, AUDIX Voice Power, AUDIX Voice Power Lodg-
    ing, and DEFINITY AUDIX) are used.
    14.
    The maximum number of users per coverage path equals
    the number of dial plan extensions (including hunt groups,
    TEGs, etc.).
    15.
    The CDRU adjunct capacity is 40,000 calls per hour, and
    exceeds the system call capacity for all systems except
    for G3r.
    38 
    						
    							SYSTEM PARAMETERS
    ITEMG3iV1.1-G3vsV2G3sV2G3iV2-G3rV2286ABP/PBPABP/PBP386
    Call Vectoring/Call Prompting
    Expert Agent Selection
    Skill GroupsNANA/24
    NA/2499255
    VDN Skill Preferences
    NANA/3NA/333
    Multiple Skills per CallNANA/3NA/333
    Multiple Skills per Agent4NA/4NA/444
    Agent Login IDsNANA/450NA/4501,50010,000
    Multiple Splits per Call
    3NA/3NA/333
    Priority Levels4NA/4NA/444
    Recorded Announcement128NA/128NA/128128256
    Steps per Vector32NA/32NA/323232
    Vector Directory Numbers500NA/100NA/100512
    20,000
    Measured VDNs
    500NA/100NA/100512
    2,000
    Vectors per System
    256NA/48NA/48256512
    CallVisor ASAI
    Active Station Controlling Assoc.
    2,000NANA/2502,0006,000
    Call Controllers per Call
    1NANA/111
    Call Monitors per Call1NANA/111
    Extension Controllers per2NANA/222
    Station Domain
    Max. Simultaneous Call Classif.
    40NANA/4040400
    No. of ASAI Links
    8NANA/488
    Notification Requests170NANA/50170460
    Simultaneous Active Adj.
    NANA/753,000
    Controlled Calls
    Switch to Adjunct Associations127NANA/127127127
    300300
    39 
    						
    							SYSTEM PARAMETERS
    ITEM
    G3iV1.1-G3vsV2G3sV2G3iV2-
    G3rV2
    286ABP/PBPABP/PBP
    Conference Parties6
    6666
    Simultaneous three-way Conf.4831611614833,542
    Calls (16)
    Simultaneous six-way Conf.
    240
    80802401,760
    Calls (17)
    Data Parameters
    Administered Connections128NA/24NA/24
    128128
    Permanent Switched CallNANANA
    NANA
    Alphanumeric Dialing
    Ma
    X. entries
    20050502001,250
    Characters/Entry222222
    2222
    Digital Data Endpoints800
    75758007,500
    Dial Plan
    DID LDNs8
    88
    820
    Extensions (18)29005003,50036,065
    Extension No. Portability (19)
    240NA/240
    NA/240
    10,00050,000
    Feature Dial Access Codes
    No. of Access Codes70
    70707070
    No. of Digits1-41-41-41-41-4
    Integrated Directory Entries1,6162072072,41625,028
    Max Extension Size55555
    386
    500
    16.
    17.
    18.
    19.
    Simultaneous three-way Conference Call=(483 / 3)*
    number PNs. Simultaneous three-way Conference Call is
    limited by the number of Simultaneous Circuit-Switched
    Calls of 180 in G3sV2.
    Simultaneous six-way Conference Call=(483 / 6)* number
    PNs.
    Extensions include stations, data endpoints, hunt groups,
    announcements, TEGs, VDNs, common shared exten-
    sions, and code calling IDs.
    The numbers shown in “Extension Number Portability”
    are Uniform Dialing Plan (UDP) entries.
    40 
    						
    							SYSTEM PARAMETERS
    ITEM
    Min Extension Size
    Miscellaneous Extensions (20)
    Names
    No. of names (21)
    No. of characters in a name
    Non-DID LDNs
    Prefix Extensions
    Trunk Dial Access Codes
    No. of Access Codes
    No. of digits
    386
    900
    900
    Do Not Disturb (DND)
    DND Requests per System
    Simultaneous Display Requests
    200200
    Facility Busy Indicators
    Buttons per Tracked Resource
    No. of Indicators (Station & Trk Grps)
    Hunt Groups or Splits
    Announcements per Group
    Announcements per System
    Groups and/or Splits
    With Hospitality Parameter
    Reduction
    Group Members per Group/Split
    Group Members per System
    G3iV1.1-
    286
    1
    3,615
    15
    50
    Yes
    157
    1-4
    1,600
    30
    100
    2400
    2
    128
    99
    5
    200
    G3vsV2
    ABP/PBP
    1
    150
    448/464
    15
    50
    Yes
    49/65
    1-4
    10
    100
    450
    2
    128
    12/24
    NA/5
    150
    150
    G3sV2
    ABP/PBP
    1
    150
    448/464
    15
    50
    Yes
    49/65
    1-4
    10
    100
    450
    2
    128
    12/24
    NA/5
    150
    150
    G3iV2-
    1
    4,215
    15
    50
    Yes
    317
    1-4
    2,400
    10
    100
    3,600
    2
    128
    99
    5
    G3rV2
    1
    3317
    36,511
    15
    666
    Yes
    884
    1-4
    25,000
    30
    100
    5,000
    2
    256
    255
    5
    5200
    200999
    500
    500
    20.
    21.
    Used for PCOL groups, common shared extensions,
    access endpoints, administered TSCs, code calling IDs,
    VDNs, LDNs, hunt groups, announcements, and TEGs.
    The Number of Names = number of stations + attendant
    consoles + trunk groups + digital data endpoints + miscel-
    laneous extensions.
    41 
    						
    							SYSTEM PARAMETERS
    ITEMG3iV1.1-G3vsV2G3sV2G3iV2-G3rV2286ABP/PBPABP/PBP
    Measured ACD Agents (Switch
    Limits)
    Agents Logged in per System
    400
    150
    1505005200
    Logged-In Splits per Agent
    444
    44
    ACD Supervisor Assist Per9912/2412/2499255
    System (22)
    Queue Slots per Group
    200200
    200200
    Queue Slots per System1000200
    2001,00010,500
    Intercom Translation Table
    (ICOM)
    Automatic/Manual  and Dial
    ICOM groups per system
    32101032256
    Auto/Manual3210
    1032256
    Dial3210
    10
    32256
    Members per ICOM group
    Auto3232323232
    Dial
    3232
    323232
    Members per System1,0243203201,0248,192
    Last Number Dialed
    Entries/System (23)2,416282
    282
    3,21632,528
    Number of Digits
    2424242424
    Leave Word Calling
    (Switch-Based) 
    (24)
    Messages Stored
    2,000450
    4502,0002,000
    Messages per User
    1010101016
    386
    999
    22.
    23.
    One supervisor assist per split.
    Last Number Dialed Entries = Stations + Digital Data
    Endpoints.
    24.
    Leave Word Calling is available with G3s ABP only if the
    Voice Mail Application Support Option is purchased.
    42 
    						
    							SYSTEM PARAMETERS
    ITEMG3iV1.1 -G3vsV2G3sV2G3iV2-
    G3rV2
    286ABP/PBP
    ABP/PBP
    386
    Remote Message Waiting
    Indicators
    Per Extension8080808080
    Per System
    808080
    80500
    Simultaneous Message Retrievers
    60606060400
    System-wide Message Retrievers1010
    101010
    Malicious Call Trace
    Max.Simultaneous Traces1616
    161616
    MLDN
    Via DID888
    820
    Via CO
    50505050
    50
    Modem Pool Groups
    Mode 2/Analog
    Group members per system
    16064
    64160
    2,016
    Number of groups
    5
    22
    563
    Members per group3232323232
    Networking
    CAS Nodes
    99NA/99NA/99
    9999
    DCS Nodes
    BX.25
    20NA/20NA/2020
    20
    ISDN PRI
    63NA/63NA/636363
    Hybrid
    63NA/63
    NA/636363
    UDP Nodes
    240NA/240NA/240240
    Partitions
    Attendant Partition111
    11
    Ext.Partition Group88888
    Extension Partition88888
    Paging
    Code Calling IDs125125125125125
    Loudspeaker Zones99999
    999
    43 
    						
    							SYSTEM PARAMETERS
    ITEMG3iV1.1-
    G3vsV2G3sV2G3iV2-G3rV2286ABP/PBP
    ABP/PBP386
    Personal CO Lines (PCOL)
    PCOL Appearances444
    4
    16
    PCOL Lines (Trunk Groups)40
    15
    15
    PCOL Trunks Per Trunk Group1 111
    1
    Port Circuit Pack Slots (25)
    Per EPN
    MCC Simplex99NANA9999
    MCC Duplex98NA
    NA
    9898
    SCC Simplex
    71NANA7171
    SCC Duplex70NANA7070
    Small Cabinet Simplex39NANA3939
    (Upgrade only)
    Small Cabinet Duplex
    38NANA3838
    (Upgrade only)
    Per PPN
    MCC Simplex89NANA8980
    MCC Duplex78NANA78
    60
    SCC Simplex64NA
    NA64NA
    SCC Duplex56NANA56NA
    ESCC Simplex
    NA70
    7070NA
    ESCC Duplex
    NANANA68NA
    CSCC SimplexNA10NANANA
    Recorded Announcements
    Analog Queue Slots per Annc.
    15050501501,000
    Analog Queue Slots per System
    150
    50
    501501,000
    200200
    25.
    Only port slots are included in this count. For example,
    there are 99 port slots per MCC EPN cabinet. One slot in
    the cabinet is already dedicated for the
    Tone/Clock board. Other service circuits may be required
    which would further reduce the number of port slots avail-
    able. In G3 carriers, a 21st slot of MCC port carriers may
    be equipped with service boards that do not require tip
    and ring connections.
    44 
    						
    							SYSTEM PARAMETERS
    256
    ITEM
    G3iV1.1-G3vsV2G3sV2G3iV2-G3rV2286ABP/PBPABP/PBP386
    Calls Connected per Annc.
    Integrated Annc. or Aux. Trunk
    5
    55
    25255
    Analog Ports555
    25128
    Channels per Integrated
    1616161616
    Annc. Circuit Pack
    Integrated Annc. Circuit Pack
    1
    111
    1
    Integrated Annc. Recording
    Time(Min:Sec)
    16 KB recording
    8:328:32
    8:328:32
    8:32
    32KB4:164:16
    4:164:164:16
    Integrated Queue Slots per System
    505050501,000
    Recorded Announcements
    128
    128128128
    System Administration
    Admin History File Entries
    2505050
    2501,250
    Simultaneous Administration
    1111
    5
    Command
    Simultaneous Maintenance
    1
    1
    11
    5
    Command
    Simultaneous SM Sessions
    53
    35
    8
    Printer Queue Size5050505050
    Speech Synthesis Circuit Packs66
    6640
    Channels per Speech Circuit Pack4
    4444
    Terminating Extension Groups
    TEGs3232323232
    Users That May Share a TEG4444
    4
    Time Slots
    Simultaneous Ckt Switched7231801807235,302
    Calls (26)
    Total Slots (27)15365125121,53611,264
    26.
    241 Simultaneous Circuit-Switched Calls per port net-
    work, except for G3s, where the maximum is 180.