Have a look at the manual ATT DEFINITY Communications System Generic 3 Pocket Reference Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 164 ATT manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
SYSTEM PARAMETERS ITEM G3iV1.1-G3vsV2G3sV2G3iV2-G3rV2286ABP/PBPABP/PBP386 Remote Access Barrier Codes1010101010 CDR Forced Entry Account1NA/1NA/111 Code List Toll Call List 1 111 1 Unresticted/Allowed Call Lists1010101010 Total Call List Entries 1,0001,0001,0001,0001,000 Automatic Callback Calls16020202401,500 Automatic Wakeup Simultaneous Display Requests1010101030 Wakeup Requests per System1,200 200 2002,40015,000 Wakeup Request per Extension 1 1111 Wakeup Requests per 15 min300150150450950 Interval Basic CMS Daily Summary Reports7 777 7 Measured Agents2007575200200 Measured Splits 9912/24 12/249999 Measured Trunk Groups 3216/3216/323232 Measured VDNs 99NA/24NA/2499512 Reporting Periods (30 or 60 min)2525252525 Number of Terminals User IDs 5 5558 Cabinets EPN MCC(8)2NANA221 SCC(8)8NANA880 Small (Upgrades only)(9)2NANA220 8. 9.The EPNs in G3r can be DS1-remote EPNs. Small systems refer to the two-carrier cabinet systems that are no longer sold to new customers. 36
SYSTEM PARAMETERS ITEM G3iV1.1-G3vsV2G3sV2G3rV2286ABP/PBP ABP/PBP Inter-Port Network Connectivity Port Networks31 13 22 Max No. of Port Networks/Cabinet1111 2 Switch Node Carriers (Simplex)NANANANA2 Switch Node Carriers (Duplex)NANANANA4 DS1 Converter Complex (Simplex)NANANANA 20 DS1 Converter Complex (Duplex)NANANANA40 PPN MCC (10)1NANA11 SCC/ESCC4NA44NA CSCC NA1NANANA Remote Modules Remote Port Network 2NANA221 Call Appearances Bridged Images/Appearance777715 Call Appearances/Station(11) 54 54545454 Max. Appearances per Ext.10 10101010 Min. Appearances per Ext.22222 Total Bridged Appearances 1,600 2002002,400 25,000 Max.Simultaneous Off-Hook 55555 per Call (12) Call Coverage Coverage Answer Groups (CAG)200 3030200750 G3iV2- 386 10.MCC includes Medium Cabinet. 11. The number of call appearances is the sum of primary and bridged appearances; at most 10 can be primary. A maximum of 54 administrable buttons are supported for the 7434D terminal—34 buttons in the basic terminal and an additional 20 buttons in the coverage module. Does not apply to conferencing. 12. 37
SYSTEM PARAMETERS ITEMG3iV1.1-G3vsV2G3sV2G3iV2-G3rV2286 ABP/PBPABP/PBP 386 Coverage Paths 6001501506007,500 With Hospitality Parameter Reduction 5NA/5NA/555 Coverage Paths Incl. in Call Covg.Report100100100100100 Coverage Path per Station (13)4 4 44 4 Coverage Points in a Path33 333 Max Users/Coverage Path(14) 29005003,50036,065 Members per CAG 888 88 Call Detail Recording CDRU Trackable Extensions1,6002002,40025,000 Intra-switch Call Trackable Extensions100100100100500 No. of CDRUs/System (15) 11 11 1 Call Forwarding (Follow-me) Call Forwarded Digits (off-net)1616 16 1616 Call Forwarded Numbers 1,600 2002002,40025,000 Call Park Attnd.Grp. Common Shared Exten.Nos.1010101080 No. of Parked Calls723180 180 7235,302 Call Pickup Groups Call Pickup Members/Group5050 505050 Call Pickup Members/System1,6002002002,40025,000 No. of Groups 800 100100 5,000 With Hosptality Parameter Reduction 5NA/5 NA/55 500 200 800 5 13.Only available with ABP when AT&T Voice Power adjunct (AUDIX, AUDIX Voice Power, AUDIX Voice Power Lodg- ing, and DEFINITY AUDIX) are used. 14. The maximum number of users per coverage path equals the number of dial plan extensions (including hunt groups, TEGs, etc.). 15. The CDRU adjunct capacity is 40,000 calls per hour, and exceeds the system call capacity for all systems except for G3r. 38
SYSTEM PARAMETERS ITEMG3iV1.1-G3vsV2G3sV2G3iV2-G3rV2286ABP/PBPABP/PBP386 Call Vectoring/Call Prompting Expert Agent Selection Skill GroupsNANA/24 NA/2499255 VDN Skill Preferences NANA/3NA/333 Multiple Skills per CallNANA/3NA/333 Multiple Skills per Agent4NA/4NA/444 Agent Login IDsNANA/450NA/4501,50010,000 Multiple Splits per Call 3NA/3NA/333 Priority Levels4NA/4NA/444 Recorded Announcement128NA/128NA/128128256 Steps per Vector32NA/32NA/323232 Vector Directory Numbers500NA/100NA/100512 20,000 Measured VDNs 500NA/100NA/100512 2,000 Vectors per System 256NA/48NA/48256512 CallVisor ASAI Active Station Controlling Assoc. 2,000NANA/2502,0006,000 Call Controllers per Call 1NANA/111 Call Monitors per Call1NANA/111 Extension Controllers per2NANA/222 Station Domain Max. Simultaneous Call Classif. 40NANA/4040400 No. of ASAI Links 8NANA/488 Notification Requests170NANA/50170460 Simultaneous Active Adj. NANA/753,000 Controlled Calls Switch to Adjunct Associations127NANA/127127127 300300 39
SYSTEM PARAMETERS ITEM G3iV1.1-G3vsV2G3sV2G3iV2- G3rV2 286ABP/PBPABP/PBP Conference Parties6 6666 Simultaneous three-way Conf.4831611614833,542 Calls (16) Simultaneous six-way Conf. 240 80802401,760 Calls (17) Data Parameters Administered Connections128NA/24NA/24 128128 Permanent Switched CallNANANA NANA Alphanumeric Dialing Ma X. entries 20050502001,250 Characters/Entry222222 2222 Digital Data Endpoints800 75758007,500 Dial Plan DID LDNs8 88 820 Extensions (18)29005003,50036,065 Extension No. Portability (19) 240NA/240 NA/240 10,00050,000 Feature Dial Access Codes No. of Access Codes70 70707070 No. of Digits1-41-41-41-41-4 Integrated Directory Entries1,6162072072,41625,028 Max Extension Size55555 386 500 16. 17. 18. 19. Simultaneous three-way Conference Call=(483 / 3)* number PNs. Simultaneous three-way Conference Call is limited by the number of Simultaneous Circuit-Switched Calls of 180 in G3sV2. Simultaneous six-way Conference Call=(483 / 6)* number PNs. Extensions include stations, data endpoints, hunt groups, announcements, TEGs, VDNs, common shared exten- sions, and code calling IDs. The numbers shown in “Extension Number Portability” are Uniform Dialing Plan (UDP) entries. 40
SYSTEM PARAMETERS ITEM Min Extension Size Miscellaneous Extensions (20) Names No. of names (21) No. of characters in a name Non-DID LDNs Prefix Extensions Trunk Dial Access Codes No. of Access Codes No. of digits 386 900 900 Do Not Disturb (DND) DND Requests per System Simultaneous Display Requests 200200 Facility Busy Indicators Buttons per Tracked Resource No. of Indicators (Station & Trk Grps) Hunt Groups or Splits Announcements per Group Announcements per System Groups and/or Splits With Hospitality Parameter Reduction Group Members per Group/Split Group Members per System G3iV1.1- 286 1 3,615 15 50 Yes 157 1-4 1,600 30 100 2400 2 128 99 5 200 G3vsV2 ABP/PBP 1 150 448/464 15 50 Yes 49/65 1-4 10 100 450 2 128 12/24 NA/5 150 150 G3sV2 ABP/PBP 1 150 448/464 15 50 Yes 49/65 1-4 10 100 450 2 128 12/24 NA/5 150 150 G3iV2- 1 4,215 15 50 Yes 317 1-4 2,400 10 100 3,600 2 128 99 5 G3rV2 1 3317 36,511 15 666 Yes 884 1-4 25,000 30 100 5,000 2 256 255 5 5200 200999 500 500 20. 21. Used for PCOL groups, common shared extensions, access endpoints, administered TSCs, code calling IDs, VDNs, LDNs, hunt groups, announcements, and TEGs. The Number of Names = number of stations + attendant consoles + trunk groups + digital data endpoints + miscel- laneous extensions. 41
SYSTEM PARAMETERS ITEMG3iV1.1-G3vsV2G3sV2G3iV2-G3rV2286ABP/PBPABP/PBP Measured ACD Agents (Switch Limits) Agents Logged in per System 400 150 1505005200 Logged-In Splits per Agent 444 44 ACD Supervisor Assist Per9912/2412/2499255 System (22) Queue Slots per Group 200200 200200 Queue Slots per System1000200 2001,00010,500 Intercom Translation Table (ICOM) Automatic/Manual and Dial ICOM groups per system 32101032256 Auto/Manual3210 1032256 Dial3210 10 32256 Members per ICOM group Auto3232323232 Dial 3232 323232 Members per System1,0243203201,0248,192 Last Number Dialed Entries/System (23)2,416282 282 3,21632,528 Number of Digits 2424242424 Leave Word Calling (Switch-Based) (24) Messages Stored 2,000450 4502,0002,000 Messages per User 1010101016 386 999 22. 23. One supervisor assist per split. Last Number Dialed Entries = Stations + Digital Data Endpoints. 24. Leave Word Calling is available with G3s ABP only if the Voice Mail Application Support Option is purchased. 42
SYSTEM PARAMETERS ITEMG3iV1.1 -G3vsV2G3sV2G3iV2- G3rV2 286ABP/PBP ABP/PBP 386 Remote Message Waiting Indicators Per Extension8080808080 Per System 808080 80500 Simultaneous Message Retrievers 60606060400 System-wide Message Retrievers1010 101010 Malicious Call Trace Max.Simultaneous Traces1616 161616 MLDN Via DID888 820 Via CO 50505050 50 Modem Pool Groups Mode 2/Analog Group members per system 16064 64160 2,016 Number of groups 5 22 563 Members per group3232323232 Networking CAS Nodes 99NA/99NA/99 9999 DCS Nodes BX.25 20NA/20NA/2020 20 ISDN PRI 63NA/63NA/636363 Hybrid 63NA/63 NA/636363 UDP Nodes 240NA/240NA/240240 Partitions Attendant Partition111 11 Ext.Partition Group88888 Extension Partition88888 Paging Code Calling IDs125125125125125 Loudspeaker Zones99999 999 43
SYSTEM PARAMETERS ITEMG3iV1.1- G3vsV2G3sV2G3iV2-G3rV2286ABP/PBP ABP/PBP386 Personal CO Lines (PCOL) PCOL Appearances444 4 16 PCOL Lines (Trunk Groups)40 15 15 PCOL Trunks Per Trunk Group1 111 1 Port Circuit Pack Slots (25) Per EPN MCC Simplex99NANA9999 MCC Duplex98NA NA 9898 SCC Simplex 71NANA7171 SCC Duplex70NANA7070 Small Cabinet Simplex39NANA3939 (Upgrade only) Small Cabinet Duplex 38NANA3838 (Upgrade only) Per PPN MCC Simplex89NANA8980 MCC Duplex78NANA78 60 SCC Simplex64NA NA64NA SCC Duplex56NANA56NA ESCC Simplex NA70 7070NA ESCC Duplex NANANA68NA CSCC SimplexNA10NANANA Recorded Announcements Analog Queue Slots per Annc. 15050501501,000 Analog Queue Slots per System 150 50 501501,000 200200 25. Only port slots are included in this count. For example, there are 99 port slots per MCC EPN cabinet. One slot in the cabinet is already dedicated for the Tone/Clock board. Other service circuits may be required which would further reduce the number of port slots avail- able. In G3 carriers, a 21st slot of MCC port carriers may be equipped with service boards that do not require tip and ring connections. 44
SYSTEM PARAMETERS 256 ITEM G3iV1.1-G3vsV2G3sV2G3iV2-G3rV2286ABP/PBPABP/PBP386 Calls Connected per Annc. Integrated Annc. or Aux. Trunk 5 55 25255 Analog Ports555 25128 Channels per Integrated 1616161616 Annc. Circuit Pack Integrated Annc. Circuit Pack 1 111 1 Integrated Annc. Recording Time(Min:Sec) 16 KB recording 8:328:32 8:328:32 8:32 32KB4:164:16 4:164:164:16 Integrated Queue Slots per System 505050501,000 Recorded Announcements 128 128128128 System Administration Admin History File Entries 2505050 2501,250 Simultaneous Administration 1111 5 Command Simultaneous Maintenance 1 1 11 5 Command Simultaneous SM Sessions 53 35 8 Printer Queue Size5050505050 Speech Synthesis Circuit Packs66 6640 Channels per Speech Circuit Pack4 4444 Terminating Extension Groups TEGs3232323232 Users That May Share a TEG4444 4 Time Slots Simultaneous Ckt Switched7231801807235,302 Calls (26) Total Slots (27)15365125121,53611,264 26. 241 Simultaneous Circuit-Switched Calls per port net- work, except for G3s, where the maximum is 180. 45