Home > ATT > Communications System > ATT DEFINITY Communications System Generic 3 Pocket Reference Instructions Manual

ATT DEFINITY Communications System Generic 3 Pocket Reference Instructions Manual

    Download as PDF Print this page Share this page

    Have a look at the manual ATT DEFINITY Communications System Generic 3 Pocket Reference Instructions Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 164 ATT manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							FEATURES
    Feature
    Off-Premises Station
    PC Interface
    PC/PBX Connection
    Personal Central
    Office Line (PCOL)
    Personalized Ringing
    Power Failure
    Transfer
    Priority Calling
    Privacy — Attendant
    Lockout
    Privacy — Manual
    Exclusion
    Property Management
    System Interface
    Pull Transfer
    Queue Status Indications
    Recall Signaling
    Recent Change History
    Recorded Announcement
    Recorded Telephone
    Dictation Access
    Redirection On No
    Answer (RONA)
    Remote Access
    Report Scheduler and
    System Printer
    Restriction —
    Controlled
    Restriction — Fully
    Restricted Service
    Restriction —
    Miscellaneous TerminalG3vs
    ABP
    S
    S
    S
    S
    S
    S
    S
    S
    S
    S
    V2
    S
    S
    S
    S
    S
    V2
    S
    S
    S
    V2
    S
    G3vs
    PBP
    S
    S
    S
    S
    S
    S
    S
    S
    S
    S
    V2
    S
    S
    S
    S
    S
    V2
    S
    S
    S
    V2
    S
    G3s
    ABP
    S
    S
    S
    S
    S
    S
    S
    S
    S
    S
    V2
    S
    S
    S
    S
    S
    V2
    S
    S
    S
    V2
    S
    G3s
    PBP
    S
    S
    S
    S
    S
    S
    S
    S
    S
    S
    V2
    S
    S
    S
    S
    S
    V2
    S
    S
    S
    V2
    S
    G3i
    S
    S
    S
    S
    S
    S
    S
    S
    S
    S
    GD
    S
    S
    S
    S
    S
    V2
    S
    S
    S
    GD
    S
    G3r
    S
    S
    S
    S
    S
    S
    S
    S
    S
    S
    V2
    S
    S
    S
    S
    S
    V2
    S
    S
    S
    S
    S
    16 
    						
    							FEATURES
    Feature
    Restriction —
    Miscellaneous Trunk
    Restriction — Toll
    Restriction — Voice
    Terminal—Inward
    Restriction — Voice
    Terminal —
    Manual Terminating
    Line
    Restriction — Voice
    Terminal—Origination
    Restriction — Voice
    Terminal—Outward
    Restriction — Voice
    Terminal—Public
    Restriction — Voice
    Terminal—Termination
    Ringback Queuing
    Ringer Cutoff
    Rotary Dialing
    R2-MFC
    Security Violation
    Notification (SVN)
    Send All Calls
    Senderized Operation
    Service Observing
    Single-Digit Dialing and
    Mixed Station Number-
    ing
    Straightforward Outward
    Completion
    Subnet Trunking
    System Measurements
    G3vs
    ABP
    S
    S
    S
    S
    S
    S
    V2
    S
    S
    S
    S
    V2
    S
    S
    S
    S
    S
    S
    S
    O
    17
    G3vs
    PBP
    S
    S
    S
    S
    S
    S
    V2
    S
    S
    S
    S
    V2
    S
    S
    S
    S
    S
    S
    S
    SG3s
    ABP
    S
    S
    S
    S
    S
    S
    V2
    S
    S
    S
    S
    V2
    S
    S
    S
    S
    S
    S
    S
    O
    17
    G3s
    PBP
    S
    S
    S
    S
    S
    S
    V2
    S
    S
    S
    S
    V2
    S
    S
    S
    S
    S
    S
    S
    SG3i
    S
    S
    S
    S
    S
    S
    GD
    S
    S
    S
    S
    GD
    S
    S
    S
    S
    S
    S
    S
    S
    G3r
    S
    S
    S
    S
    S
    S
    V2
    S
    S
    S
    S
    V2
    S
    S
    S
    S
    S
    S
    S
    S
    17.Available when the System Measurements Option package or
    the Basic Call Center Option package is purchased.
    17 
    						
    							FEATURES
    G3vs
    G3vsG3s
    G3s
    Feature
    ABPPBP
    ABPPBPG3iG3r
    System Status Report
    SSSSSS
    Temporary Bridged
    S
    SSSSS
    Appearance
    Terminal Translation
    V2V2V2V2V2
    S
    Initialization
    Terminating ExtensionSS
    SSSS
    Group
    Through Dialing
    S
    SSSSS
    Time of Day Routing
    O18O18O18O18O18O18
    Timed Reminder and
    S19S19S19S19S19S19
    Attendant Timers
    Touch-Tone Dialing
    S
    SSSSS
    Transfer
    SSSSSS
    Transfer OutgoingV220V2V220V2V2S
    Trunk
    to Outgoing Trunk
    Traveling Class
    N/AO
    N/AO00
    Marks (TCMs)
    Trunk Flash
    S
    SSSSS
    Trunk Group
    SS
    SSSS
    Busy/Warning
    Indicators to Attendant
    Trunk Identification
    S
    SSSSS
    By Attendant
    Trunk-to-Trunk TransferSS
    SSSS
    Uniform Dial Plan (UDP)N/AO
    N/AOO
    O
    18.
    19.
    20.
    Available when ARS or PNA is purchased.
    Timed Reminder and Attendant Timers held call timer transfer to
    “aatd.” Standard in G3vs/G3sABP, G3vs/G3sPBP, G3i, and G3r.
    Transfer Outgoing Trunk to Outgoing Trunk is not available with
    G3vs/G3s ABP.
    18 
    						
    							FEATURES
    Feature
    Unrestricted Uniform
    Dial Plan (UDP)
    Visually Impaired Atten-
    dant
    Services (VIAS)
    Voice Message Retrieval
    Voice Response
    Integration
    Voice Terminal Alerting
    Options
    Voice Terminal Display
    Wideband Switching
    World Class Tone
    Detection
    World Class Tone
    Generation
    G3vs
    ABP
    NA
    V2
    S
    V2†
    V2
    S
    V2†
    V2
    V2G3vs
    PBP
    V2
    V2
    S
    V2†
    V2
    S
    V2†
    V2
    V2G3s
    ABP
    NA
    V2
    S
    V2†
    V2
    S
    V2†
    V2
    V2
    G3s
    PBP
    V2
    V2
    S
    V2†
    V2
    S
    V2†
    V2
    V2
    G3i
    V2
    GD
    S
    V2†
    V2
    S
    V2†
    GD
    GD
    G3r
    O
    V2
    S
    V2†
    V2
    S
    V2†
    V2
    V2
    19 
    						
    							FEATURES
    The following table describes which features require additional hardware.
    Feature
    Abandoned Call Search
    Abbreviated Dialing
    ACCUNET® Service
    Administered Connections
    Answer Detection
    Attendant Direct Exten-
    sion Selection With Busy
    Lamp Field
    Hardware
    TN747B CO trunk circuit pack.
    Requires additional 748B tone detectors if the
    special “wait” character is used frequently.
    Modular processor data module (MPDM) AP
    Demand Print+An AP, an MPDM, and a
    printer.
    Access endpoint circuit packs used: TN767
    DS1 interface or TN760B tie trunk.
    Data endpoint circuit packs used: TN726 data
    line or TN754 digital line.
    Trunk circuit packs used: TN767 DS1 inter-
    face and TN760 tie trunk.
    TN758 pooled modem circuit pack.
    Data modules used: 700A or 700D PDM or
    MPDM, 700B, C, or E TDM or MTDM, 7400D
    series voice terminal or 7400B with PC/PBC.
    TN744 call classifier circuit pack.
    A selector console is used.
    20 
    						
    							FEATURES
    Feature
    Audio Information
    Exchange (AUDIX)
    Automatic Call Distr-
    bution (ACD)
    Automatic Circuit
    Assurance
    Automatic Incoming
    Call Display
    Automatic Route
    Selection
    Hardware
    TN742 or TN746B analog line circuit pack.
    TN765 processor interface, MPDM for 2CA6
    AUDIX. If PI is used, one port on a TN754
    digital line, and an MTDM and MPDM.
    One port on a TN742, TN746B, or TN769 ana-
    log line circuit pack per auxiliary queue warn-
    ing level lamp.
    Each analog announcement requires
    announcement equipment and one port on an
    Analog Line circuit pack. Each integrated
    announcement, which is accessed by a call,
    requires one port on a TN750 integrated
    announcement circuit pack.
    If music is to be heard after the delay
    announcement, a music source and a port on
    a TN763B auxiliary trunk circuit pack is
    required.
    Display-equipped voice terminal. If the desti-
    nation is not the terminal, a TN725 speech
    synthesis circuit pack is used.
    A display-equipped voice terminal, or a voice
    terminal capable of displaying information
    through an attached data terminal.
    When this feature is used in a private network,
    additional TN748C tone detectors, as well as
    tie trunks can be required.
    21 
    						
    							FEATURES
    Feature
    Automatic Wakeup
    BCMS
    Call-by-Call Service
    Selection
    Hardware
    If voice prompting is used, a TN725B voice
    synthesizer circuit pack is required. Each cir-
    cuit pack has four ports to provide voice
    prompting. If voice synthesis announcements
    are used, two ports must be reserved for
    announcements.
    A Cook Electronic Recorder/Announcer or an
    Audichron® Company model HQD614B
    Recorder/Announcer and power supply is
    installed in the auxiliary cabinet. Either
    recorder/announcer requires a TN763B.
    Any of the following connections can be used
    to connect an asynchronous printer to the sys-
    tem: the EIA port on the processor circuit
    pack; PDM to a digital port; ADU to a data line
    port.
    A TN767 DS1 interface circuit pack is used for
    a signaling link, and up to 23 ISDN-PRI trunk
    group members. A TN741 or TN768 tone-
    clock circuit pack, and a TN765 processor
    interface circuit pack are used.
    22 
    						
    							FEATURES
    Feature
    Call Detail Recording
    (CDR)
    Call Prompting
    CallVisor® ASAI inter-
    face
    Hardware
    Hardware requirements depend on the type of
    output device used for SMDR.
    A printer, personal computer or tape unit (Data
    Terminal Equipment) — An MPDM to a port
    on a TN754 digital line circuit pack or a 212A-
    type modem to a port on a TN742 analog line
    circuit pack. In the latter case, a standard
    pooled modem is required for the data path.
    Host computer — A private line terminated at
    the System 85 with a trunk data module
    (TDM). Also, a private line modem if the com-
    puter is off-premises.
    A TN726 data line circuit pack can be used in
    conjunction with an Asynchronous Data Unit
    (ADU) to connect a printer.
    Each announcement requires a port on a
    TN750 integrated announcement circuit pack
    or announcement equipment and a port on a
    TN742 or TN746B analog line. A maximum of
    10 TN744 call classifier circuit packs can be
    used.
    The following circuit packs are used: TN744
    tone detectors when an ASAI application
    makes switch classified calls (such as a
    predictive dialing outbound call management
    application); TN7556 ISDN-BRI for use with an
    ASAI BRI link; TN778 packet control for G3i
    and G3s and TN1655 packet control for G3r.
    A TN750 EI is used if there is an EPN.
    23 
    						
    							FEATURES
    Feature
    Centralized Attendant
    Service (CAS) (Branch
    or Main)
    Code Calling Access
    Data Call Setup
    Hardware
    A TN760D tie trunk circuit pack is used.
    Either a TN722B DS1 tie trunk circuit pack or
    a TN767B DS1 interface circuit pack can also
    be used for the release link trunks of the CAS
    network.
    Loudspeaker paging equipment and one port
    on a TN763B auxiliary trunk circuit pack per
    zone. These hardware requirements can be
    shared with the Loudspeaker Paging Access
    feature. A 278A adapter is used if the
    customer’s equipment is not FCC-registered.
    Each data module requires one port on a
    TN754 digital line circuit pack. A digital termi-
    nal data module (DTDM) shares the port with
    a voice terminal.
    Each AT&T personal computer (PC) requires
    one port on a TN754 digital line circuit pack for
    shared use of voice and data.
    Each 7401D, 7404D, 7406D, or 7407D voice
    terminal requires one port on a TN754 digital
    line circuit pack for shared use of voice and
    data.
    Each modem requires one port on a TN742
    analog line circuit pack.
    24 
    						
    							FEATURES
    Feature
    Data Call Setup (continued)
    Data-Only Off-Premises
    Extensions
    Distributed Communica-
    tions System (DCS)
    Features
    Digital Multiplexed Interface
    (DMI)
    Direct Department Calling
    and Uniform Call Distribu-
    tion
    Hardware
    Modem pooling requires either a TN758
    modem pool circuit pack or one digital port
    with a TDM or MTDM, and one analog port
    with analog modem for each conversion
    resource.
    Keyboard Dialing to off-premises (out-of-
    building) data endpoints requires the use of a
    TN748C tone detector circuit pack.
    Extensive use of features and services using
    tone detection may require additional TN748C
    circuit packs. Several other features also use
    a TN748C.
    A TDM and one port on a TN754 digital line
    circuit pack.
    DCS interface hardware.
    One of the following can be used: TN722B
    DS1 circuit pack per 24 DMI trunks; one
    TN767B; one TN464.
    One port on a TN742 analog line circuit pack
    per queue warning level lamp is used with
    announcement equipment. If music is to be
    heard after the delay announcement, a music
    source and a port on a TN763B auxiliary trunk
    circuit pack is used. A TN750 announcement
    circuit pack provides up to 64 different
    announcements.
    25 
    						
    All ATT manuals Comments (0)

    Related Manuals for ATT DEFINITY Communications System Generic 3 Pocket Reference Instructions Manual