Page 1491
System Hardware and Software Capacity Limits Issue 3 March 1996 A-81 1. Only EPNs in G3r can be DS1-remote EPNs. 2. Small systems refer to the 2-carrier cabinet systems no longer sold to new customers. 3. MCC includes the Medium Cabinet. 4. The number of appearances is the sum of p rimary and bridged appearances; at most 10 c an be primary. A maximum of 54 administrable buttons are supported for the 7434D terminal — 34 b uttons in the basic terminal and 20 additional buttons in the coverage...
Page 1492
System Parameters A-82Issue 3 Marc h 1996 1. All references to Hosp itality Parameter Reduction on the Customer O ption form have b een removed from the Cap acities Tables. 2. The maximum number of users per coverage path is equal to the number of extensions. Table A-5. Maximum System Parameters for G3V4 Release 3.0 — continued ITEMG3vsV4 ABP/PBP G3siV4 G3siV4 +m G3rV4 Call Coverage Coverage Answer Groups (CAG) 30 30 200 750 Coverage Paths 1150 150 60 0 7, 50 0 Coverage Paths Including in Call...
Page 1493
System Hardware and Software Capacity Limits Issue 3 March 1996 A-83 1. Measured limits depend on the CMS release used. 2. Proprietary, exists in G3V3 only. 3. Simultaneous 3-way Conference Call = (483 / 3)* number PNs. 4. Simultaneous 6-way Conference Call = (483 / 6)* number PNs. Table A-5. Maximum System Parameters for G3V4 Release 3.0 — continued ITEMG3vsV4 ABP/PBP G3siV4 G3siV4 +m G3rV4 Call Vectoring Maximum Skills a Call Can Simultaneously Queue to NA/3 3 3 3 Prio rit y Le vels NA /4 4 4 4...
Page 1494
System Parameters A-84Issue 3 Marc h 1996 1. Login IDs count against the “Extensions” switch capacity. 2. These numbers are Uniform Dialing Plan (UDP) entries. 3. The Integrated Directory Entries = Stations + Attendant Consoles. 4. Used for PCOL g roups, common shared extensions, ac cess endpoints, administered TSCs, c ode calling IDs, LDNs, hunt groups, announcements, and TEGs. 5. The Number of Names = number of stations + attendant c onsoles + trunk g roups + digital data endpoints +...
Page 1495
System Hardware and Software Capacity Limits Issue 3 March 1996 A-85 1. All references to Hosp itality Parameter Reduction on the Customer Option form have been removed from the Cap acities Tables. Table A-5. Maximum System Parameters for G3V4 Release 3.0 — continued ITEMG3vsV4 ABP/PBP G3siV4 G3siV4 +m G3rV4 Dial Plan (Continued) Trunk Dial Access Codes Number of Ac cess Codes 49/65 65 317 884 Number of Digits 1-4 1-4 1-4 1-4 Do Not Disturb (DND) DND Requests per System 400 400 2,400 25,000...
Page 1496
System Parameters A-86Issue 3 Marc h 1996 1. The Last Number Dialed Entries = Stations + Digital Data Endpoints + Attendant Consoles. 2. Leave Word Calling is available in the ABP only if the Voice Mail Option is purchased. Table A-5. Maximum System Parameters for G3V4 Release 3.0 — continued ITEMG3vsV4 ABP/PBP G3siV4 G3siV4 +m G3rV4 Intercom Translation Table (ICOM) Aut om at i c /M an ua l a n d Dia l ICOM groups per system 10 10 32 256 Au to/ Ma nu al 10 10 32 25 6 Dial 10 10 32 256 Members per...
Page 1497
System Hardware and Software Capacity Limits Issue 3 March 1996 A-87 1. The actual limit in the software is 63, but due to p erformance c onsiderations the recommended number of DCS Nodes is 20. 2. These are node number ad dresses. 3. Only p ort slots are included in this count. For example, there are 100 p ort slots per MCC EPN cabinet. One slot in the c abinet is already d edicated for the Tone/Clock board. Other service c ircuits may b e required that would further reduce the number of port slots...
Page 1498
System Parameters A-88Issue 3 Marc h 1996 1. The G3r has been resized to 4000 q ueue slots for the 10 boards maximum (only 1,000 is needed for one board), since common pool architecture requires a greater number of total queue slots. Table A-5. Maximum System Parameters for G3V4 Release 3.0 — continued ITEMG3vsV4 ABP/PBP G3siV4 G3siV4 +m G3rV4 Port Circuit Pack Slots (Continued) Per Processor Port Network (PPN) MCC Standard ReliabilityN//A N/A 89 80 SCC S ta nda rd Rel ia b i lit y NA N/A 64 NA...
Page 1499
System Hardware and Software Capacity Limits Issue 3 March 1996 A-89 1. 241 simultaneous circuit-switched calls per port network, exc ept for G3vs and G3si with 180 and G3r with 7,712 (limited by number of call records sup ported). 2. G3V4 uses TN744 Call Classifier for b asic TTR usage as well as call p rompting/call c lassification/MFC. Also, the TN2182 Tone/Clock/Detector is used for multiple tone detection functions. The number of TN748, TN420, or TN744 boards is limited only by the number of...
Page 1500
System Parameters A-90Issue 3 Marc h 1996 1. Only one Processor Interface (PI) c ircuit pack is sup ported in G3vs (CSCC) and G3s (ESCC) configurations, therefore a total of 4 physical links (used for BX.25 or PRI) are available. PRI interface via the PI is not available in Germany. PRI interface via the Packet Controller is used. 2. PRI interface via the Packet Controller is not available on G3vs. Therefore, PRI is not available on G3vs in Germany. Other Countries must use the PI when they have the...