Page 1451

System Hardware and Software Capacity Limits
Issue  3   March 1996
A-41
1. Only port slots are included in this count. For example, there are 99 port slots per MCC EPN c abinet.
One slot in the cabinet is already dedicated for the Tone/Clock board. Other service c ircuits may be
required which would  further reduce the number of p ort slots available. In G3 c arriers, the 21st slot of
MCC port carriers may be equip p ed  with service boards that do not require tip and ring connections.
Table A-2. Maximum...

Page 1452

System Parameters
A-42Issue  3   Marc h 1996 
Table A-2. Maximum System Parameters for G3V1.1 or V2 — continued
ITEMG3iV1.1-
286G3vsV2 
ABP/PBPG3sV2 
ABP/PBPG3iV2-
386 G3rV2
Recorded Announcements
Analog Queue Slots per
Announcement150 50 50 150 1,000
Analog Queue Slots per System 150 50 50 150 1,000
Calls Connec ted per
Announcement
Integrated Announcement or 
Auxiliary Trunk55 525255
Ana lo g  Port s 5 5 5 25 128
Channels per Integrated 
Announcement Circuit Pack16 16 16 16 16
Integrated Announcement...

Page 1453

System Hardware and Software Capacity Limits
Issue  3   March 1996
A-43
1. 241 Simultaneous Circuit-Switched Calls per port network, except for G3s, where the maximum is
180.
2. 512 time slots per port network.
3. 483 time slots for Voice and Data per port network. Even though an EPN is supported in G3sV2,
giving a total of two port networks, G3sV2 is engineered to support only 180 Simultaneous
Circuit-Swit ched Calls.
Table A-2. Maximum System Parameters for G3V1.1 or V2 — continued
ITEMG3iV1.1-...

Page 1454

System Parameters
A-44Issue  3   Marc h 1996 
1. Only one PI board is supported in G3vs/G3s (both MCC and SCC), and therefore a total of four
physical links, used for BX.2 5 or PRI , a re a vai lab le .
In G3i, two PI boards  can be supported in the MCC, and therefore a total of eight physical links (used
for BX25 or PRI) are availab le. Sinc e the SCC c an only supp ort one PI board, a total of four physical
links (used for BX25 or PRI) are available in the SCC 286 an d Me dium config urations.
2. All...

Page 1455

System Hardware and Software Capacity Limits
Issue  3   March 1996
A-45
1. All BRI stations can be disp lay stations.
2. In G3, ‘‘Station Button Capacity (units) ‘replaces’ Maximum Button Modules.’’
The following  exam ples show how these units c an b e used. The assumption is that only three c all
appearances are assigned to the sets (except analog sets which have no call appearance).
— Analog sets (for example, 7104A): G3r, 76 units; all other releases, 62 units.
— Digital sets with 10 buttons (for...

Page 1456

System Parameters
A-46Issue  3   Marc h 1996 
1. No limit on the maximum number of auto dial buttons (other than the system limit on button capacity).
2. In th e c ase  of  SCC/ ESCC/CSCC, only four BX.25 physical links are sup p orted in the configuration.
Table A-3. Maximum System Parameters for G3V3
ITEMG3vsV3 
ABP/PBPG3sV3 
ABP/PBP G3iV3 G3rV3
Abbreviated Dialing (AD)
AD Lists Per System 200 200 2,400 5,000
AD List Entry Size 24 24 24 24
AD Entries Per System 2,000 2,000 12,000 100,000
Auto Dialing...

Page 1457

System Hardware and Software Capacity Limits
Issue  3   March 1996
A-47
1. All references to Hospitality Parameter Red uc tion on the Customer Option form have been removed .
2. In the c ase where going from 4 to 3 login maximums, a change to the hunt group form will also be
required, which in turn would require all agents to be logged-out. In one extreme c ase, this is
p o ten ti all y avo i d e d  a n d  R2  & R3 CMS  wil l ha n d l e the  fo ur th lo g i n  a s UNST AFFED, a p propriately.
3. R3V 3...

Page 1458

System Parameters
A-48Issue  3   Marc h 1996 
1. This is the number of 12 character inserted-digit-strings available for AAR/ARS  preferences.
2. The number for G3vs V2/V3 (4) is the recommended number of c onsoles that should be supported due
to power limitations. Of the four consoles, one may be used as a night console. The software actually
sup ports 6:1 day/night attendant consoles.
3. The numb er of ‘‘Release Link Trunk Groups at Main’’ is the same as the number of trunk groups in the
system.
Table...

Page 1459

System Hardware and Software Capacity Limits
Issue  3   March 1996
A-49
1. Referred  to as ‘‘emergency access queue length’’ in G3i.
Table A-3. Maximum System Parameters for G3V3 — continued
ITEMG3vsV3 
ABP/PBPG3sV3 
ABP/PBP G3iV3 G3rV3
Attendant Service (Continued)
Other Access Queues
Maximum Number of Queues 12 12 12 12
Maximum Number of Queue Slots
130 30 80 80
Size Range of Reserved Queue 2-25 2-25 2-75 2-75
Rese rved  Queue  Def au lt Size 5 5 5 5
Queue Len gth 30 30 80 300
Switched Loops/Console 6...

Page 1460

System Parameters
A-50Issue  3   Marc h 1996 
1. Only EPNs  in  G3r  can  be DS1-remote EPNs.
2. Small systems refer to the 2-carrier cabinet systems that are no longer sold to new customers.
3. MCC includes Medium Cabinet.
Table A-3. Maximum System Parameters for G3V3 — continued
ITEMG3vsV3 
ABP/PBPG3sV3 
ABP/PBP G3iV3 G3rV3
Basic CMS
Measured Agents or Login IDs 75 75 200 600
Measured Splits 12/24 12/24 99 99
Measured Trunk Groups 16/32 16/32 32 32
Measured VDNs NA/24 NA/24 99 512
Reporting Period s...