System Hardware and Software Capacity Limits Issue 3 March 1996 A-41 1. Only port slots are included in this count. For example, there are 99 port slots per MCC EPN c abinet. One slot in the cabinet is already dedicated for the Tone/Clock board. Other service c ircuits may be required which would further reduce the number of p ort slots available. In G3 c arriers, the 21st slot of MCC port carriers may be equip p ed with service boards that do not require tip and ring connections. Table A-2. Maximum...
Page 1452
System Parameters A-42Issue 3 Marc h 1996 Table A-2. Maximum System Parameters for G3V1.1 or V2 — continued ITEMG3iV1.1- 286G3vsV2 ABP/PBPG3sV2 ABP/PBPG3iV2- 386 G3rV2 Recorded Announcements Analog Queue Slots per Announcement150 50 50 150 1,000 Analog Queue Slots per System 150 50 50 150 1,000 Calls Connec ted per Announcement Integrated Announcement or Auxiliary Trunk55 525255 Ana lo g Port s 5 5 5 25 128 Channels per Integrated Announcement Circuit Pack16 16 16 16 16 Integrated Announcement...
Page 1453
System Hardware and Software Capacity Limits Issue 3 March 1996 A-43 1. 241 Simultaneous Circuit-Switched Calls per port network, except for G3s, where the maximum is 180. 2. 512 time slots per port network. 3. 483 time slots for Voice and Data per port network. Even though an EPN is supported in G3sV2, giving a total of two port networks, G3sV2 is engineered to support only 180 Simultaneous Circuit-Swit ched Calls. Table A-2. Maximum System Parameters for G3V1.1 or V2 — continued ITEMG3iV1.1-...
Page 1454
System Parameters A-44Issue 3 Marc h 1996 1. Only one PI board is supported in G3vs/G3s (both MCC and SCC), and therefore a total of four physical links, used for BX.2 5 or PRI , a re a vai lab le . In G3i, two PI boards can be supported in the MCC, and therefore a total of eight physical links (used for BX25 or PRI) are availab le. Sinc e the SCC c an only supp ort one PI board, a total of four physical links (used for BX25 or PRI) are available in the SCC 286 an d Me dium config urations. 2. All...
Page 1455
System Hardware and Software Capacity Limits Issue 3 March 1996 A-45 1. All BRI stations can be disp lay stations. 2. In G3, ‘‘Station Button Capacity (units) ‘replaces’ Maximum Button Modules.’’ The following exam ples show how these units c an b e used. The assumption is that only three c all appearances are assigned to the sets (except analog sets which have no call appearance). — Analog sets (for example, 7104A): G3r, 76 units; all other releases, 62 units. — Digital sets with 10 buttons (for...
Page 1456
System Parameters A-46Issue 3 Marc h 1996 1. No limit on the maximum number of auto dial buttons (other than the system limit on button capacity). 2. In th e c ase of SCC/ ESCC/CSCC, only four BX.25 physical links are sup p orted in the configuration. Table A-3. Maximum System Parameters for G3V3 ITEMG3vsV3 ABP/PBPG3sV3 ABP/PBP G3iV3 G3rV3 Abbreviated Dialing (AD) AD Lists Per System 200 200 2,400 5,000 AD List Entry Size 24 24 24 24 AD Entries Per System 2,000 2,000 12,000 100,000 Auto Dialing...
Page 1457
System Hardware and Software Capacity Limits Issue 3 March 1996 A-47 1. All references to Hospitality Parameter Red uc tion on the Customer Option form have been removed . 2. In the c ase where going from 4 to 3 login maximums, a change to the hunt group form will also be required, which in turn would require all agents to be logged-out. In one extreme c ase, this is p o ten ti all y avo i d e d a n d R2 & R3 CMS wil l ha n d l e the fo ur th lo g i n a s UNST AFFED, a p propriately. 3. R3V 3...
Page 1458
System Parameters A-48Issue 3 Marc h 1996 1. This is the number of 12 character inserted-digit-strings available for AAR/ARS preferences. 2. The number for G3vs V2/V3 (4) is the recommended number of c onsoles that should be supported due to power limitations. Of the four consoles, one may be used as a night console. The software actually sup ports 6:1 day/night attendant consoles. 3. The numb er of ‘‘Release Link Trunk Groups at Main’’ is the same as the number of trunk groups in the system. Table...
Page 1459
System Hardware and Software Capacity Limits Issue 3 March 1996 A-49 1. Referred to as ‘‘emergency access queue length’’ in G3i. Table A-3. Maximum System Parameters for G3V3 — continued ITEMG3vsV3 ABP/PBPG3sV3 ABP/PBP G3iV3 G3rV3 Attendant Service (Continued) Other Access Queues Maximum Number of Queues 12 12 12 12 Maximum Number of Queue Slots 130 30 80 80 Size Range of Reserved Queue 2-25 2-25 2-75 2-75 Rese rved Queue Def au lt Size 5 5 5 5 Queue Len gth 30 30 80 300 Switched Loops/Console 6...
Page 1460
System Parameters A-50Issue 3 Marc h 1996 1. Only EPNs in G3r can be DS1-remote EPNs. 2. Small systems refer to the 2-carrier cabinet systems that are no longer sold to new customers. 3. MCC includes Medium Cabinet. Table A-3. Maximum System Parameters for G3V3 — continued ITEMG3vsV3 ABP/PBPG3sV3 ABP/PBP G3iV3 G3rV3 Basic CMS Measured Agents or Login IDs 75 75 200 600 Measured Splits 12/24 12/24 99 99 Measured Trunk Groups 16/32 16/32 32 32 Measured VDNs NA/24 NA/24 99 512 Reporting Period s...