System Hardware and Software Capacity Limits
Issue  3   March 1996
A-71
1. The Last Number Dialed Entries = Stations + Digital Data Endpoints + Attendant Consoles.
2. Leave Word Calling is available in the ABP only if the Voice Mail Option is purchased.
Table A-4. Maximum System Parameters for G3V4 Release 1.0 — continued
ITEMG3vsV4 
ABP/PBPG3sV4 
ABP/PBP G3iV4 G3rV4
Intercom Translation Table (ICOM)
Automatic/Manual and Dial
ICOM groups per system 10 10 32 256
Auto/ Ma nu al 10 10 32 25 6
Dia l 10 10 32...

Page 1482

System Parameters
A-72Issue  3   Marc h 1996 
1. The actual limit in the software is 63, but due to performance c onsiderations, the recommended
number of DCS Nodes is 20.
2. The numbers here are node number addresses.
3. G3V2 AND G3V3 do not support Tenant Partitioning.
4. Only  port slots are included in this  count. For example, there are 100 p ort slots p er MCC EPN  cabinet.
One slot in the cabinet is already dedicated for the Tone/Clock b oard. Other service c ircuits may be
required which would...

Page 1483

System Hardware and Software Capacity Limits
Issue  3   March 1996
A-73
1. This c apacity for the G3vs and G3s was reduc ed to make the capacity proportional to that provided in
the larger sizes (about 25% of the maximum number of system trunks for one board). G3i integrated
queue slots should b e increased to 100 for one b oard (200 for 5 boards) but c an not b e d one in this
release due to memory limitation (each q ueue slot requires 18 bytes). The G3r has been resized to
4000 q ueue slots for the 10...

Page 1484

System Parameters
A-74Issue  3   Marc h 1996 
1. 241 Simultaneous Circuit-Swit ched Calls p er port network, except for G3vs and G3s with 180 and G3r
with f 7,712 (limited by the number of call records supported).
2. There are 483 time slots for Voice and Data per port network.
3. G3V3 Release 3.0 or later, or G3V4 , use TN7 44  Ca ll  Cla ssifier for basic TTR usage as well as call
prompting/call c lassification/MFC. Also, the TN2182 Tone/Clock/Detector is used for multiple tone
detection functions. The...

Page 1485

System Hardware and Software Capacity Limits
Issue  3   March 1996
A-75
1. Only one Processor Interface (PI) is sup ported  in G3vs (CSCC) and G3s (ESC C) c on f i g ura tio n s,
therefore a total of 4  physical links (used for BX.25 or PRI) are available. PRI interface via the PI is not
available in Germany. PRI interface via the Packet Control must be used.
2. PRI interface via the Packet Control is not available on G3vs. PRI is not available on G3vs in Germany.
Other Countries must use the PI when...

Page 1486

System Parameters
A-76Issue  3   Marc h 1996 
1. The following items detract from the total number of available “Stations” on a given switch:
— Analog Music-On-Hold
— Attendants
— Modem Pool Conversion Resources
— TAA S P ort
— Stations (Digital, Display, BRI, etc.)
— Analog  Announcements
— Analog  External Alarm Port
— Agent Login IDs
— ACD Agents
2. All BRI stations can be disp lay stations (G3vs does not sup port BRI).
3. The software limit for digital stations in G3vs is 200 stations, b ut due to...

Page 1487

System Hardware and Software Capacity Limits
Issue  3   March 1996
A-77
1. No limit on maximum number of auto dial buttons (other than system limit on button capac ity).
2. In  th e c ase  of  SCC/ ESCC/CSCC, only four BX.25 physical links are sup p orted in the configuration.
Table A-5. Maximum System Parameters for G3V4 Release 3.0
ITEMG3vsV4 
ABP/PBP G3siV4 G3siV4 
+m G3rV4
Abbreviated Dialing (AD)
AD Lists Per System 400 400 2,400 5,000
AD List Entry Size 24 24 24 24
AD Entries Per System 2,000 2,000...

Page 1488

System Parameters
A-78Issue  3   Marc h 1996 
1. All references to Hospitality Parameter Reduction on the Customer O ption form have b een removed from
the Cap acities Tab les.
2. When going  from 4 to 3 login maximums, a c hange to the hunt group form is required. This mean all
agents must be logged-out. In one extreme case, this is potentially avoided and R2 & R3 CMS handles
the fourth login as UNST AFF ED,  a p p r o p r i ate ly.
3. R3V 3  CMS  wa s  ren am e d  to  R3 V4  CM S t o m at c h t he  DEF...

Page 1489

System Hardware and Software Capacity Limits
Issue  3   March 1996
A-79
1. Number of available 12 character inserted-digit-strings available for AAR/ARS preferences.
2. Recommended number of c onsoles supported due to power limitations. Of the four consoles, one may
be used as a night console. The software actually supports 6:1 day/night attendant consoles.
3. This is the same as the number of trunk groups in the system.
4. Referred  to as ‘‘emergency access queue length’’ in G3s.
Table A-5. Maximum...

Page 1490

System Parameters
A-80Issue  3   Marc h 1996 
Table A-5. Maximum System Parameters for G3V4 Release 3.0 — continued
ITEMG3vsV4 
ABP/PBP G3siV4 G3siV4 
+m G3rV4
Authorization
Authorization Codes 1,500 1,500 5,000 90,000
Station Security Code Length 4 4 4 4
Classes of Restriction 96 96 96 96
Classes of Service 16 16 16 16
Length of Authorization Code 4-7 4-7 4-7 4-7
Length of Barrier Code 4-7 4-7 4-7 4-7
Length of A c count Codes NA/1-15 1-15 1-15 1-15
Restricted  Call List 1 1 1 1