Page 1471
System Hardware and Software Capacity Limits Issue 3 March 1996 A-61 1. The following items detract from the total number of available “Stations” on a given switch: — Analog Music-On-Hold — Attendants — Modem Pool Conversion Resources — TAA S P ort — Stations (Digital, Display, BRI, etc.) — Analog Announcements — Analog External Alarm Port — Agent Login IDs — ACD Agents 2. All BRI stations can be disp lay stations (G3vs does not sup port BRI). 3. The software limit for digital stations in G3vs is...
Page 1472
System Parameters A-62Issue 3 Marc h 1996 1. No limit on the maximum number of auto dial buttons (other than the system limit on button capacity). 2. In th e c ase of SCC/ ESCC/CSCC, only four BX.25 physical links are sup p orted in the configuration. Table A-4. Maximum System Parameters for G3V4 Release 1.0 ITEMG3vsV4 ABP/PBPG3sV4 ABP/PBP G3iV4 G3rV4 Abbreviated Dialing (AD) AD Lists Per System 200 200 2,400 5,000 AD List Entry Size 24 24 24 24 AD Entries Per System 2,000 2,000 12,000 100,000...
Page 1473
System Hardware and Software Capacity Limits Issue 3 March 1996 A-63 1. All references to Hospitality Parameter Red uc tion on the Customer Option form have been removed. 2. In the c ase where going from 4 to 3 login maximums, a change to the hunt group form is required, forcing all agents to be logged-out. In one extreme case, this is potentially avoided and R2 & R3 CMS handles the fourth login as UNSTAFFED ap propriately. 3. R3V 3 CMS wa s ren am e d to R3 V4 CM S t o ma t c h t he DEF INIT Y...
Page 1474
System Parameters A-64Issue 3 Marc h 1996 1. This is the number of 12 character inserted-digit-strings available for AAR/ARS preferences. 2. The number for G3vs V2/V3 (4) is the recommended number of c onsoles that should be supported due to power limitations. Of the four consoles, one may be used as a night console. The software actually sup ports 6:1 day/night attendant consoles. 3. This number is the same as the number of trunk groups in the system. 4. Referred to as ‘‘emergency access queue...
Page 1475
System Hardware and Software Capacity Limits Issue 3 March 1996 A-65 Table A-4. Maximum System Parameters for G3V4 Release 1.0 — continued ITEMG3vsV4 ABP/PBPG3sV4 ABP/PBP G3iV4 G3rV4 Attendant Service (continued) Queue Len gth 30 30 80 300 Swit c h e d Lo o p s p e r Con sol e 6 6 6 6 Authorization Authorization Codes 1,500 1,500 5,000 90,000 Classes of Restriction 96 96 96 96 Classes of Service 16 16 16 16 Length of Authorization Code 4-7 4-7 4-7 4-7 Length of Barrier Code 4-7 4-7 4-7 4-7 Length...
Page 1476
System Parameters A-66Issue 3 Marc h 1996 1. Only EPNs in G3r can be DS1-remote EPNs. 2. Small systems refer to the 2-carrier cabinet systems that are no longer sold to new customers. 3. MCC includes Medium Cabinet. 4. The number of c all appearances is the sum of p rimary and bridged ap pearances; at most 10 can be primary. A maximum of 54 administrable buttons are supported for the 7434D terminal — 34 b uttons in the basic terminal and an additional 20 buttons in the coverage module. 5. Does...
Page 1477
System Hardware and Software Capacity Limits Issue 3 March 1996 A-67 1. The maximum number of users per coverage path is equal to the number of extensions. 2. The CDRU adjunct c apacity is 40,000 c alls per hour, and it exc eeds the system c all c apacity for all systems exc ept for G3r. Table A-4. Maximum System Parameters for G3V4 Release 1.0 — continued ITEMG3vsV4 ABP/PBPG3sV4 ABP/PBP G3iV4 G3rV4 Call Coverage (Continued) Coverage Paths Included in Call Coverage Report100 100 100 100 Coverage...
Page 1478
System Parameters A-68Issue 3 Marc h 1996 1. Measured limits depend on the CMS release used. 2. Proprietary, exists in G3V3 only. 3. Simultaneous 3-way Conference Call = (483 / 3)* number PNs. 4. Simultaneous 6-way Conference Call = (483 / 6)* number PNs. Table A-4. Maximum System Parameters for G3V4 Release 1.0 — continued ITEMG3vsV4 ABP/PBPG3sV4 ABP/PBP G3iV4 G3rV4 Call Vectoring Maximum Skills a Call Can Simultaneously Queue toNA/3 NA/3 3 3 Priority Levels NA/4 NA/4 4 4 Re c ord e d An no un c...
Page 1479
System Hardware and Software Capacity Limits Issue 3 March 1996 A-69 1. Login IDs count against the “Extensions” switch capacity. 2. The numbers shown in ‘‘Extension Number Portability’’ are Uniform Dialing Plan (UDP) entries. 3. The Integrated Directory Entries = Stations + Attendant Consoles. 4. Used for PCOL groups, common shared extensions, access endpoints, administered TSCs, code calling IDs, LDNs, hunt groups, announcements, and TEGs. 5. The Number of Names = number of stations + attendant...
Page 1480
System Parameters A-70Issue 3 Marc h 1996 1. With G3V4 and later releases this limit is enforced. However, c ustomers up grading to V4 or a later release are not forced to decrease the number of buttons. Table A-4. Maximum System Parameters for G3V4 Release 1.0 — continued ITEMG3vsV4 ABP/PBPG3sV4 ABP/PBP G3iV4 G3rV4 Do Not Disturb (DND) DND Requests per System 200 200 2,400 25,000 Simultaneous Display Requests 10 10 10 30 Expert Agent Selection (EAS) Skill Groups NA/24 NA/24 99 255 VDN S kill Pre...