Page 51
Installationbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Task 11: Perform Initial DEFINITY LAN Gateway Administration bbbbbbbbbbbbbbb This task is required for all installation scenarios. There are two parts to this task: Task 11A: Set the DEFINITY LAN Gateway Clock Task 11B: Assign the DEFINITY LAN Gateway Machine ID (Optional) Task 11A: Set the DEFINITY LAN Gateway Clock 1. At the login prompt, enter craft. The system displays the Password prompt. 2. Enter the default password for the craft...
Page 52
Installationbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb 3. Brouter Administration 1. Login/Password Administration 4. Maintenance... 5. Port Status/Control 6. Exit This line is used to provide abbreviated help on the currently selected field. ENTERMain Menu 2. TCP/IP Administration... EXIT REFRESH Release 1.0, Issue x.y HELP Screen 2-4. Main Menu 5. Select Maintenance and then Set System Time and Date. Follow the instructions for the Set System Time and Date screen in Chapter 3. Task 11B:...
Page 53
Installationbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Host Name: ______________________________ Host IP Address: __________________ Subnet Mask: __________________TCP/IP Administration This Host This line is used to provide abbreviated help on the currently selected field. ENTER CLEAR CANCEL REFRESHHELP Screen 2-5. This Host 2. If a host name different from the default (definity) is desired, in the Host Name field type the new name to be assigned to this DEFINITY LAN Gateway...
Page 54
Installationbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb 4410 for a 4410 or 5410 terminal; enter 4410 also for a 610/615 BCT or a PC with a 4410 emulation package. 4425 for a 4425 or 5425 terminal 5420 for a 5420 or 4415 terminal g3-ma for a G3-MA vt220 (or other terminal listed in Appendix B) 4. The system displays the DEFINITY LAN Gateway Main Menu. 3. Brouter Administration 1. Login/Password Administration 4. Maintenance... 5. Port Status/Control 6. Exit This line is used to provide...
Page 55
Installationbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Task 13: Test LAN/Client Connectivity (Optional) bbbbbbbbbbbbbbb Task 13 is performed to test the TCP/IP connection to ensure that connectivity exists between the DEFINITY LAN Gateway and the customers LAN, as well as between the DEFINITY LAN Gateway and a client. This testing should be done jointly with the customers LAN administrator. NOTE: Connectivity to the DEFINITY LAN Gateway system from a subscriber PC is not part of the acceptance...
Page 56
Installationbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Host Name or IP Address: ____________________Maintenance This line is used to provide abbreviated help on the currently selected field. ENTER CLEAR CANCEL REFRESHHELP Ping Host Packet count: Packet size:___ ___ Screen 2-7. Ping Host Screen b. Fill in the Host Name or IP Address of the DEFINITY LAN Gateway system assembly. This example uses 192.168.25.10 as the IP Address. Also enter a packet count of 20 (recommended), and a packet size of...
Page 57
Installationbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Output similar to the following will appear: The messages which follow are the result of your last request. At the : prompt press return to continue. 72 bytes from 192.168.25.10: icmp_seq*0, time=0. xx 72 bytes from 192.168.25.10: icmp_seq*1, time=0. xx 72 bytes from 192.168.25.10: icmp_seq*2, time=0. xx 72 bytes from 192.168.25.10: icmp_seq*3, time=0. xx 72 bytes from 192.168.25.10: icmp_seq*4, time=0. xx 72 bytes from 192.168.25.10:...
Page 58
Installationbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb d. Now access the Ping Host screen again, as you did in step 2a, to test connectivity to the client. Use the same data, except in this example, enter 192.168.25.20 as the IP address (if you choose to enter IP Address instead of Name). In this step, the DEFINITY LAN Gateway system assembly is sending packet messages (20 in this example) to the client, and listening for responses. Output similar to the following will appear: The messages...
Page 59
Installationbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb The results displayed in the packet loss field (z) will range from 0% to 100% The number of packets that are ``lost (need to be transmitted) will vary from LAN to LAN. For some LANs, 0% packet loss is normal, while for others, 10% or 20% loss is normal. The degree of packet transmission over a LAN depends upon the distance between machines, the number of users on the LAN, and the number of machines on the LAN. Refer to the sections that...
Page 60
Installationbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb Task 14: Register/Back Up the Systembbbbbbbbbbbbbbb The final three steps the AT&T service technician performs to install the DEFINITY LAN Gateway system are as follows: Task 14A: Register the System Task 14B: Deactivate/Activate Logins Task 14C: Perform a Backup of the Removable Medium Task 14A: Register the System AT&T Services personnel should call the TSC at 1-800-248-1111 to register the system. Expect the TSC to collect information...