TRUNK TYPE AND SIGNALING TYPE COMPATIBILITY TABLESD-3
TABLE D-1. Trunk/Signaling Cross References (continued)½
TrunkProcedureFeatureDirectionSignalingProcedure
DescriptionEncodeTypesEncode
1-way out DOD17CO1-way outGS 1
LS19
DMI/ISDN-MOS20
E&M auto in, IS out28
E&M auto in, WS out29
1-way out DOD with party test(18)CO1-way outGS party test(2)
2-way attendant completing in, DOD19CO2-wayGS 1
LS19
DMI/ISDN-MOS20
E&M auto in, IS out28
E&M auto in, WS out29
2-way with party test(20)CO2-wayGS party test(2)...

Page 252

D-4TRUNK TYPE AND SIGNALING TYPE COMPATIBILITY TABLES
TABLE D-1. Trunk/Signaling Cross References (continued)
TrunkProcedureFeatureDirectionSignalingProcedure
DescriptionEncodeTypesEncode
1-way in dial repeating32TIE
1-way inE&M IS in, IS out 4
1-way out auto33TIE1-way outE&M IS in, auto out31
analog line loop27
1-way out dial repeating34TIE
1-way outE&M IS in, IS out 4
GS 1
1-way in auto35TIE
1-way inE&M auto in, IS out28
GS 1
2-way dial repeating both ways36TIE2-wayE&M IS in, IS out 4
2-way dial...

Page 253

TRUNK TYPE AND SIGNALING TYPE COMPATIBILITY TABLESD-5
TABLE D-1. Trunk/Signaling Cross References (continued)½
TrunkProcedureFeatureDirectionSignalingProcedure
DescriptionEncodeTypesEncode
code call interface53N/AN/Aaux. equipment 7
loudspeaker paging interface54N/AN/Aaux. equipment 7
TT sender55N/AN/Anone 0
CAS interface56N/AN/Anone 0
RLT for CAS57CAS1-way outE&M RLT out13
ANI interface58N/AN/A
ANI signaling 6
station msg register interface59
N/AN/Anone 0
unused60
UCD lamp interface61N/AN/Anone 0
music...

Page 254

D-6TRUNK TYPE AND SIGNALING TYPE COMPATIBILITY TABLES
TABLE D-1. Trunk/Signaling Cross References (continued)½
TrunkProcedureFeatureDirectionSignalingProcedure
DescriptionEncodeTypesEncode
host access, 2-way, PIM
103N/A2-wayS-Channel signaling18
host access off-premises, DTIM104N/A2-wayS-Channel signaling18½
½
host access, AP32105N/A2-wayS-Channel signaling18
host access, EIA106N/A2-wayS-Channel signaling18
host access, ISN107N/A2-wayS-Channel signaling18
DMI A-bit, wink in, auto out
108N/A2-wayE&M WS...

Page 255

TRUNK TYPE AND SIGNALING TYPE COMPATIBILITY TABLESD-7
Table D-3, Signaling Type Compatibility, provides the compatibility of standard signaling types. The
first column is the frame of reference for the direction compatibility. Compatibility is either 1-way out,
1-way in, or bidirectional from this entry.
TABLE D-3. Signaling Type Compatibility
Encode000102030405060708091011121314151617181920212223242526272829303132
00
.
01.
02.
03.
04.¬ ¬¬ ¬
® ®® ®¬ ¬
® ®
05® ®¬ ¬¬ ¬¬ ¬.¬ ¬¬ ¬¬ ¬.¬ ¬¬ ¬
® ®
06.
07.
08®...

Page 256

D-8TRUNK TYPE AND SIGNALING TYPE COMPATIBILITY TABLES
Table D-4, Signaling Type Definitions, provides definitions for the signaling types used in the other three
tables in this appendix.
TABLE D-4. Signaling Type Definitions½
Procedure
EncodeTrunk
DescriptionTraditional
Module BoardUniversal
Module Board
00no signaling requiredN/AN/A
01
GSSN230, ANN11TN747B, TN767
02GS with party test
SN230None
03
LRB, wink startSN232, ANN11TN753, TN767
04E&M IS in and out
SN233, ANN11TN760C, TN767
05E&M WS in, IS...

Page 257

E. TIE TRUNK SETTINGS
This appendix contains the ISDN-PRI-specific administration settings that must be assigned to enable
DEFINITY® Generic 1.1 to System 85 R2V4 communications systems to communicate via ISDN-PRI
tie trunks.
System 85 Administration Settings
Table E-1, System 85 R2V4 Administration Settings, shows the basic System 85 administration settings
needed to implement ISDN-PRI tie trunks between the two communications systems. The
administration procedures are shown in the order they should be...

Page 258

E-2TIE TRUNK SETTINGS
TABLE E-1 (continued). System 85 R2V4 Administration Settings
PROCEDUREWORDFIELDREMARKS
26011-4Enter the address of the ANN35 that you want to administer.
The analogous Generic 1 administration is in the Location
field of the 
DS-1 CIRCUIT PACK screen.
6This field is to assign either D4 or ESF (Fe) framing format.
ESF framing should be assigned here. If ESF is assigned and
if the ESF T1 CSU is optioned to pass ESF through
transparently, then the misframes registered in procedure...

Page 259

TIE TRUNK SETTINGSE-3
TABLE E-1 (continued). System 85 R2V4 Administration Settings
PROCEDURE
WORDFIELDREMARKS
260111This field is for loop around testing. External loop around
should be enabled only during a maintenance test.
The analogous Generic 1 administration is in the Remote
Looparound Test field of the DS1 CIRCUIT PACK screen.
12The setting for this field depends on whether the ISDN-PRI
circuit pack is a timing source. This field must be set
consistent with the overall synchronization plan, which...

Page 260

E-4TIE TRUNK SETTINGS
TABLE E-1 (continued). System 85 R2V4 Administration Settings
PROCEDURE
WORDFIELDREMARKS
26217Assign a 3 here if a System 85 is equipped with an SN261,
analog/digital facility test circuit pack. If an SN261 is not
present, assign a 1 here. A 3 allows level 2 and 3 tests in
procedure 648. A 1 allows only level 2 tests.
8-12These fields are for the terminal endpoint identifier and various
timers and counters. They are assigned default values when
the ANN35 board is assigned in...