Page 281
TIE TRUNK SETTINGSE-25 TABLE E-7 (continued). Trunk Group Screen Settings — Generic 1 FIELDSETTINGREMARKS Max Message Size128128 bytes is the largest message a System 85 R2V4 can To Sendreceive. Connected tonoThis is a private network arrangement without connection to a Toll?toll office. Send SID?YAssign a y here if you want the calling partys station number and/or connected partys number sent to a System 85 R2V4 on the far end. The analogous System 85 R2V4 administration is in procedure 100, word 3,...
Page 282
E-26TIE TRUNK SETTINGS that routes the call. The Per Call SID/ANI field can be used to request SID/ANI only for specific calls incoming on the group. The Night Serv field is used to have calls of different types routed to different night destinations when night service is in effect. This table is generally used when a Generic 1 is connected to the public network with several different services (such as MEGACOM® 800 service and ACCUNET® Switched Digital Services) but also has private network...
Page 283
TIE TRUNK SETTINGSE-27 Routing Patter Screen Settings This screen is used to build the routing patterns for ISDN-PRI calls made to a System 85 R2V4. The patterns are selected using the HNPA, FNPA, RHNPA, and RNX tables. The only ISDN-PRI-specific fields in this screen are the IXC, BCC value, and Service/Feature fields. The BCC value fields can be used to route calls based on their ISDN BCs and low-layer compatibilities, such as voice versus mode 1 digital data. The subnet trunking feature is also present...
Page 284
E-28TIE TRUNK SETTINGS TABLE E-9. Routing Pattern Screen Settings — Generic 1 FIELD SETTINGREMARKS IXCLeave this field blank for this application. 101288 is the interexchange (long distance) carrier code for AT&T. Since this is a private network, this field does not apply. BCC ValueThis is where Generalized Route Selection (GRS) is implemented. If you want only certain types of calls to be routed to specific trunk groups, enter a y for those types of calls in the desired preference. Enter n for those...
Page 285
TIE TRUNK SETTINGSE-29 SID PREFIX TABLE ExtExtSIDExtExtSIDExtExtSID LenCodePrefixLenCodePrefixLenCodePrefix 56561948566619495676194956861949 Figure E-13. SID PREFIX TABLE Screen TABLE E-10. SID Prefix Table Screen Settings — Generic 1 FIELD SETTING REMARKS Ext LenThis field and the next constitute a key that determines which row of the table to apply to a call. Enter the number of extension digits in the dial plan. For example, if you are on a five digit dial plan, enter 5. You can also use this table...
Page 286
E-30TIE TRUNK SETTINGS TABLE E-10 (continued). SID Prefix Table Screen Settings — Generic 1 FIELD SID Prefix SETTINGREMARKS Enter the digits you add to the extension code digits to form a 10-digit SID number. For example, in the sample screen shown above, if any extension of the form 65XXX places or answers a call, the number sent to a System 85 on the far end will be 619-486-5XXX. In the example, the other numbers that would be sent are 619-496-6XXX, 619-496-7XXX, 619- 496-8XXX. Terminating Extension...
Page 287
INDEX 011 calls C-1 1 1s density 1-17, 1-20 2 24th-channel signaling 1-14, 1-15, 2-3 4 4-wire E&M extended range channel units 2-5 5 50-pin (25-pair) connector configurations B-14 551V channel service unit 6-2 551V ST channel service unit 6-2 5ESS to another system 2-7 6 6500 IDSN Advantage 1-21 A AAR assignments 7-46 access ACCUNET 6-3, C-16 code dial 7-26, 7-88 trunk 7-24, 7-86 connector, ISDN B-16 digital, and cross-connect system (DACS) 2-6, 5-6, B-12 equal 7-44, 7-47, 7-105, 7-108 ISDN 7-30 line...
Page 288
IN-2INDEX ANN11C/ANN11E feature comparison 6-2 APLT 7-34 area code 7-19 arithmetic logic unit (ALU) 4-3 ARS 2-6 ATMS Generic 2 7-110 System 85 7-49 AT&T ISDN basic rate interface (BRI) 1-3 nodal services 1-31 primary rate interface (PRI) 1-3 proprietary signaling 1-14 reference frequency 2-7, 5-28 attendant partitions 7-20 Automatic Alternate Routing (AAR) BC 1-25 called party IE 7-39 CBC 7-25, 7-31, 7-93 feature groups 7-4 feature parameters 7-108 ISDN dynamic trunk group C-6 network characteristics...
Page 289
INDEXIN-3 cabling — Contd CEM and CDM configurations 3-11 DS1 transmission 3-1 metallic 3-2 nonmetallic options 3-10 off-premises 3-9 on-premises 3-6 Call-by-Call Service Selection advantages 1-30 description 1-29 Generic 1 services 7-127 ISDN public network connections 7-103 trunk type 120 7-25, 7-31, 7-87, 7-93 called party IE 1-29 calling line ID 1-34 calling number identifier 1-34 call-reference IE 1-29 call-reference value (CRV) 1-28 cancelers echo 3-9 CAS 1-32 cascode node connections 5-24 CBC...
Page 290
IN-4 INDEX combination tie trunk 2-5, 6-4 common-channel signaling 1-23 Common-Control Switching Arrangement (CCSA) 1-34 communication protocols 1-20 comparison — System 75 R1V2 versus System 85/G2 7-113 compensation settings, line equalizer 3-13 composite clock output 5-16 conclusions on synchronization 5-29 connected number IE 1-32 connection, special access 2-6 connections using DS1/DMI terminal equipment 2-9 controlled slip 5-3 COR 7-120, 7-139, A-2 COS C-1 BC and ISDN routing 7-84...