Page 141
ADMINISTRATION OPTIONS AND REQUIREMENTS — GENERIC 27-63 Field 13Assigns whether a DS1 facility (translated in field 12) will be used as the primary or secondary synchronization source to the switch. Field encodes and their descriptions are: 0 Assigns that the facility is not used as a synchronization source 1 Assigns that the facility is the primary synchronization source 2 Assigns that the facility is the secondary synchronization source NOTE: The primary must be administered before the secondary. The...
Page 142
7-64ADMINISTRATION OPTIONS AND REQUIREMENTS — GENERIC 2 Field 14Field encodes and their descriptions are: 0 Assigns that the DS1/DMI-BOS channels can be used for both trunks and lines (mixed); the latter is frequently called off-premises stations (OPS). 1 Assigns that the interface is used to provide DMI-BOS trunks. The DMI-BOS trunk groups are defined using procedure 100, word 1 (encode 108 and/or 109). DMI-BOS applications use the switchs DS1 to provide a high-speed multiplexed data interface for...
Page 143
ADMINISTRATION OPTIONS AND REQUIREMENTS — GENERIC 27-65 Field 15Some facilities require that the contents of the D-channel be inverted to guarantee that the minimum ones density be maintained (that is, ZCS line coding is used). This field shows whether the D-channel is inverted or not. Field encodes and their descriptions are: - (Dash) not applicable or ZCS line coding is translated in field 9. The dash is appropriate for all applications of the ANN11 circuit pack. RBS does not use the 24th-channel to...
Page 144
7-66ADMINISTRATION OPTIONS AND REQUIREMENTS — GENERIC 2 Field 18Loop length refers to the total cable distance between the switch and the NCTE, CDM, BCM32000, DSX-1 cross-connect, and T1 office repeater. Traditional modules may contain the ANN11 and/or ANN35 circuit packs. Both circuit packs contain DIP switches for setting the compensation value [refer to table 3-1, System 85 Traditional Module Equalizer Settings (Metallic Cable) ]. Therefore, software administration is not applicable and the (–) should...
Page 145
ADMINISTRATION OPTIONS AND REQUIREMENTS — GENERIC 27-67 Field 20This display-only field serves to show which cables contain which synchronization cables. Procedure 262 Word 1: Additional DMI-MOS/ISDN-PRI Facility Options Procedure 262 is used to administer the ANN35 and TN767 circuit packs. Figure 7-29, Procedure 262 Word 1: Additional DMI-MOS/ISDN-PRI Facility Options (Generic 2), depicts this procedure.½ ENHANCED MODE — PROCEDURE: 262, WORD: 1 ISDN BOARD PARAMETERS EQUIPMENT LOCATION 13. PRI Interface...
Page 146
7-68ADMINISTRATION OPTIONS AND REQUIREMENTS — GENERIC 2 Field 6Assigns this interface as the user (0) or the network (1) side. When connected to a 4ESS, the customer premises switch is always the user side. When not connected to a 4ESS (that is, when connected to another switch), one switch is the user side and the other the network side.½ ½ ½ For MOS facilities (such as DMI-MOS and ISDN-PRI), each link must be segmented into user and network sides. At a Generic 2, each MOS-based facility connected to...
Page 147
ADMINISTRATION OPTIONS AND REQUIREMENTS — GENERIC 27-69 Field 9The field accepts encodes from 0 through 255, which correspond to 1 second intervals for a maximum elapsed time of 4 minutes and 15 seconds. The default value for this T203 timer is 30 (30 seconds). This timer functions to monitor the facility data link and specifies the maximum time allowed without frames being exchanged on a data link layer connection. Field 10The field accepts encodes from 0 through 255, which correspond to 0.1 seconds...
Page 148
7-70ADMINISTRATION OPTIONS AND REQUIREMENTS — GENERIC 2 ENHANCED MODE — PROCEDURE: 262, WORD: 2 ISDN NFAS/D-CHANNEL BACKUP 1. D-Channel Group Number: PRIMARY D-CHANNEL EQUIPMENT LOCATION 2. 3. 4. 5.Module: Cabinet: Carrier: Slot: BACKUP D-CHANNEL EQUIPMENT LOCATION 6. 7. 8. 9.Module: Cabinet: Carrier: Slot: DISPLAY ONLY 10. Number of Trunks Assigned to This D-Channel Group: Connected to CC0 ON-LINE enter command:½ Field 1Figure 7-30. Procedure 262 Word 2: ISDN-PRI D-Channel Backup (Generic 2) Identifies...
Page 149
ADMINISTRATION OPTIONS AND REQUIREMENTS — GENERIC 27-71 Procedure 262 Word 3: ISDN-PRI Codeset Map Assignments Depending on the terminating switch it may be necessary to administer a Codeset Map Assignment and convert from one codeset or codepoint to a different codeset or codepoint. This administration assignment is required for ISDN-PRI links originating on a Generic 2 and terminating on a System 85 R2V4. Figure 7-31, Procedure 262 Word 3: ISDN-PRI Codeset Map Assignments (Generic 2), depicts½ this...
Page 150
7-72ADMINISTRATION OPTIONS AND REQUIREMENTS — GENERIC 2 Field 7Assigns whether hyperactivity management will be enabled for the ISDN-PRI link. Hyperactivity is defined as erratic behavior by the D-signaling channel. Typically, a hyperactive link will generate an excessive amount of meaningless traffic. Excessive D-channel traffic may overload the module processor and degrade system performance.½ Field encodes and their descriptions are: - (Dash) not applicable. This would be administered for all ISDN-BRI...