Appendix B: Error Messages 605 (ET_CKSHMEM), MAJOR ET has Tried to Check/Reinit its SHMEM (ETCOUNTS) ET tried to check/reinitialize its shared memory. If this message occurs continuously without a user’s request, ET will not work properly until this is fixed. n Try stopping and restarting the system. n If this message persists, call your AT&T Field Service Representative for assistance. 606 (ET_ESLOT), INFORM ET Discarded Msg of Type : Error Count Array Full A software error exists or ET is...
Page 212
Appendix B: Error Messages 609 (ET_NO_ATT), MAJOR Cannot open ATT Error Rules File (vs/data/errors) n Check to see that the file /vs/data/errors exists and check its permissions. 610 (ET_NOQ), CRITICAL ET Cannot Open its Message Queue Something is wrong with the interprocess communication. ET cannot open its message queue. n Try stopping and restarting the system. n Call your AT&T Field Service Representative for assistance. 611 (ET_NORULES), MAJOR ET Cannot Access Error Rules File () ET cannot...
Page 213
Appendix B: Error Messages 613 (ET_NO_ VAR), INFORM Cannot open VAR Error Rules File (gendb/data/errors) This is an informational message unless there is supposed to be a VAR error file. The application-specific error rules file is missing. n Contact the provider of the application software package that is installed. 616 (ET_SHMIT), INFORM ET Shared Memory (SHMEM ETCOUNTS) Init ET initialized its shared memory. This is an informational message. No action is required. 617 (ET_SHOWER), STATUS ET...
Page 214
Appendix B: Error Messages 621 (ET_FLOOD), INFORM This message is printed as a result of the flood control being turned on to prevent messages from flooding the screen or the ET history file. 622 (ET_URS), CRITICAL User Ordered ET to RESTART System The user ordered ET to restart the system. 623 (ET_URB), CRITICAL User Ordered ET to REBOOT System The user ordered ET to restart the system. 624 (ET_WIPE), INFORM ET Removed Defunct Process () from Bulletin Board ET removed a defunct processor an invalid...
Page 215
Appendix B: Error Messages 627 (ET_BAD_ARGS), INFORM Invld channel ()/brd() for msgid() Recvd from ET received a message with bad arguments (for example, an invalid board number, invalid channel number for the given board number, etc.). 628 (ET_NEW_PID), MAJOR ET Noticed PID for changed: to ; Proc probably respawned ET noticed the process ID for a given process changed, which indicates that the process probably died and respawned. n This message should be reported to your AT&T Field Service...
Page 216
Appendix B: Error Messages 654 (ET_SUMSHOW), STATUS ET showed summary settings as requested The user ordered ET to display its current summary settings. The user made the request via the etset command. 655 (ET_SUMTIME), STATUS ET set summary Interval to minutes as requested The user ordered ET to set its summary interval for the time between the display of summary messages to the specified number of minutes via the etset command. Maintenance (MTC) Process 700 (STA_CHAN), STATUS MTC reports channel is...
Page 217
Appendix B: Error Messages 711 (INV_TSMR), INFORM MTC received Invalid tsmr, state= , mcont= Maintenance received an invalid response from TSM. The response has been ignored. This is an indication of software problems. n If this error persists, try stopping and restarting the system. 712 (INV_MESG), INFORM MTG received invalid message, state=, morig=, mcont= Maintenance received an invalid message while interacting with TSM. The message has been ignored. This is an indication of software problems. n...
Page 218
Appendix B: Error Messages 715 (SEND_MSG), CRITICAL MTC cannot send a message, return= , errno= Maintenance cannot send messages. This is an indication of system problems. n Try stopping and restarting the system or rebooting the system. 716 (UNK_TYPE), MAJOR MTC detected an invalid type (), on card Maintenance detected an invalid device type in shared memory. This is an indication of system problems. n Try stopping and restarting the system or rebooting the system. 717 (SYS_FAIL), MAJOR MTC...
Page 219
Appendix B: Error Messages 722 (GET_SEMA), MAJOR MTC cannot acquire the semaphore Maintenance cannot create the semaphore. This is an indication of system problems. n Try stopping and restarting the system or rebooting the system. 723 (SET_SEMA), MAJOR MTC cannot set the semaphore Maintenance cannot lock the semaphore. This is an indication of software problems. n Try stopping and restarting the system or rebooting the system. 724 (SHM_FAIL), CRITICAL MTC cannot attach the area Maintenance...
Page 220
Appendix B: Error Messages 727 (CLR_SEMA), MAJOR MTC cannot clear the semaphore Maintenance cannot unlock the semaphore. This is an indication of software problems. n Try stopping and restarting the system or rebooting the system. 740 (DG_START), STATUS MTC reports diag started on () card Maintenance reports that diagnostics have started on a hardware card. 741 (DG_RESLT), STATUS MTC reports diag results on card , return=, errno=, Maintenance reports on diagnostic results. 742 (DG_PASSD), STATUS...