Page 81

Example: 
. 
 
Lower Limit: Set the lower limit value of the Alarm. 
Upper Limit: Set the upper limit value of the Alarm 
◆Variable Lower/Upper Limit 
Variable Lower/Upper Limit: If checked, it means the  upper/lower limit alarm value 
uses the variable register.. 
Addr.Type:  Address type of the variable register, it is a word register 
Address: The first address of the variable register 
Word Length:  Word length of the variable regi ster, the default is 2. Suppose the 
variable register Address that...

Page 82

 
Related attributes: 
 X Y X&Y 
First address Graphic state Graphic state Graphic state 
First address +1 Movement on X 
axis  Movement on X  axis Movement on X axis 
First address +2 — — Movement on Y  axis 
Some explains : 
X 
Scaling, Y 
Scaling. Moving component move along the  X and Y axis horizontally, we 
can set the relative movement position by value input and  proportional 
value(For    example ,the range X axis read from PLC is from 0 to 640, 
but the relative position we want to  show on...

Page 83

 
X 
Scaling, Y 
Reverse 
Scaling Moving component moves along the  X and Y axis horizontally, we 
can set the relative movement  position by the value input and 
proportional value 。But the Moving component moves along Y axis in the 
reveres direction. 
X 
Reverse 
Scaling, Y 
Scaling Moving component moves along the  X and Y axis horizontally, we 
can set the relative movement  position by the value input and 
proportional value 。But the Moving component moves along X axis in the 
reveres direction 
X...

Page 84

Proportional Upper Limit of Y ,Proportional Lower Limit of Y are read from the 
register. 
Example: 
  Suppose the moving way of Moving component is  X Reverse Scaling, and Y 
Reverse Scaling. 
The address of Variable Min/Max  is LW10, so the values of Maximum of X, 
Minimum of X, Proportional Upper Limit  of X, Proportional Lower Limit of X, 
Maximum of Y, Minimum of X, Proportional Upper Limit of Y, Proportional Lower 
Limit of Y  are the values of LW10,LW11,LW12,Lw13,LW14,LW15,Lw16,LW17. As in the...

Page 85

 
2, A local register LW10015, when the value of LW10015 turn to 0, the event content 
is cleared. How to use: pl ace a Multiple State Setting component , the address is 
LW10015, Setting Mode is Set Constant , Set Value is 0. 
3, When download the project, select  Clear History Event in the EVManger, as 
shown in the picture: 
 
4, Scroll Bar 
In Scroll Bar, adds a option of Scroll  Bar Extended Attributes, it contains Slider Width 
and  Variable Max/Min Value.  
1 Basic Attributes  

Page 86

 
Addr.Type:: Address type of the variable register, it is a word register 
Address: Address of Scroll Bar component, that  is scanning    index address of Scroll 
Bar. 
Word Length : Number of    register address for Scroll Bar, the default was 3 before 
and change to 1 now. The register of the first scanning index value and max scanning 
index value are changed to Variable Min/Max Value register. 
2 Scroll Bar Extended Attributes:  

Page 87

 
Slider Width: if checked, that is to say you can  set the width of Scroll Bar manually 
(The width ranges from 1 to 30    ),If not che cked, the width is the default value 10(Pixels) 
 
Max/Min Value Setting 
Min: The minimum of scroll Bar, that is t he first scanning index value.(ranges from 
-2147483648 to 2147483647)   
Max:  The maximum of scroll Bar, that is  the max scanning index value.(ranges from 
-2147483648 to 2147483647) 
 
If the  Max/Min Value  are constants,you need not to set the value...

Page 88

5 Trend Curve, XY Plot and Oscillograph 
Add Extended Attributes option in Trend Curve, XY Plot and Oscillograph: the 
extended functions are: 
1 Use Grid , Background Color and so on. 
2 Connect Style of sampling points 
3 Variable Period is available in Trend Curve, XY Plot  
4  
5 Number of Points can uses variable value 
6 Trend Curve can be saved in HMI or external device 
 
 
When period and number of points use the variable value, the variable 
values are used in priority; if the va riable values...

Page 89

 
 
The effect of Edit Window is like that: 
 
The effect of offline simulation:  

Page 90

 
 
 
 
6 Multiple State Switch   
1 In the Multi-State Switch option, add a Unloop function, the def ault is uncheck the 
function  