Page 81
Example: . Lower Limit: Set the lower limit value of the Alarm. Upper Limit: Set the upper limit value of the Alarm ◆Variable Lower/Upper Limit Variable Lower/Upper Limit: If checked, it means the upper/lower limit alarm value uses the variable register.. Addr.Type: Address type of the variable register, it is a word register Address: The first address of the variable register Word Length: Word length of the variable regi ster, the default is 2. Suppose the variable register Address that...
Page 82
Related attributes: X Y X&Y First address Graphic state Graphic state Graphic state First address +1 Movement on X axis Movement on X axis Movement on X axis First address +2 — — Movement on Y axis Some explains : X Scaling, Y Scaling. Moving component move along the X and Y axis horizontally, we can set the relative movement position by value input and proportional value(For example ,the range X axis read from PLC is from 0 to 640, but the relative position we want to show on...
Page 83
X Scaling, Y Reverse Scaling Moving component moves along the X and Y axis horizontally, we can set the relative movement position by the value input and proportional value 。But the Moving component moves along Y axis in the reveres direction. X Reverse Scaling, Y Scaling Moving component moves along the X and Y axis horizontally, we can set the relative movement position by the value input and proportional value 。But the Moving component moves along X axis in the reveres direction X...
Page 84
Proportional Upper Limit of Y ,Proportional Lower Limit of Y are read from the register. Example: Suppose the moving way of Moving component is X Reverse Scaling, and Y Reverse Scaling. The address of Variable Min/Max is LW10, so the values of Maximum of X, Minimum of X, Proportional Upper Limit of X, Proportional Lower Limit of X, Maximum of Y, Minimum of X, Proportional Upper Limit of Y, Proportional Lower Limit of Y are the values of LW10,LW11,LW12,Lw13,LW14,LW15,Lw16,LW17. As in the...
Page 85
2, A local register LW10015, when the value of LW10015 turn to 0, the event content is cleared. How to use: pl ace a Multiple State Setting component , the address is LW10015, Setting Mode is Set Constant , Set Value is 0. 3, When download the project, select Clear History Event in the EVManger, as shown in the picture: 4, Scroll Bar In Scroll Bar, adds a option of Scroll Bar Extended Attributes, it contains Slider Width and Variable Max/Min Value. 1 Basic Attributes
Page 86
Addr.Type:: Address type of the variable register, it is a word register Address: Address of Scroll Bar component, that is scanning index address of Scroll Bar. Word Length : Number of register address for Scroll Bar, the default was 3 before and change to 1 now. The register of the first scanning index value and max scanning index value are changed to Variable Min/Max Value register. 2 Scroll Bar Extended Attributes:
Page 87
Slider Width: if checked, that is to say you can set the width of Scroll Bar manually (The width ranges from 1 to 30 ),If not che cked, the width is the default value 10(Pixels) Max/Min Value Setting Min: The minimum of scroll Bar, that is t he first scanning index value.(ranges from -2147483648 to 2147483647) Max: The maximum of scroll Bar, that is the max scanning index value.(ranges from -2147483648 to 2147483647) If the Max/Min Value are constants,you need not to set the value...
Page 88
5 Trend Curve, XY Plot and Oscillograph Add Extended Attributes option in Trend Curve, XY Plot and Oscillograph: the extended functions are: 1 Use Grid , Background Color and so on. 2 Connect Style of sampling points 3 Variable Period is available in Trend Curve, XY Plot 4 5 Number of Points can uses variable value 6 Trend Curve can be saved in HMI or external device When period and number of points use the variable value, the variable values are used in priority; if the va riable values...
Page 90
6 Multiple State Switch 1 In the Multi-State Switch option, add a Unloop function, the def ault is uncheck the function