Page 31
Specific attribute is as following table. Not tick The X,Y positions of dynamic graph are constant. The Upper-left Corner of Variable Tick The X,Y positions of dynamic graph are variable.X position = the first address,Y position = second address Not tick The width/height of dynamic graph are constant. The Widthe/Height of Variable Tick The width/height of dynamic gr aph are variable. Width = first address, Height = second address. For example: 1.Dynamic circle graph,set the...
Page 32
2. Dynamic circle graph,set the address of the upper-left corner of variable as LW0,and set the address of the width/height of variable as LW2.Set LW0=50,LW1=80,LW2=200,LW4=100. The effect is as following figure:
Page 33
9. Event Bar Event Bar component is used to rolling display th e current trigger event information. 1.Event Info Scrollbar Component Attribute
Page 34
Display Type Range: Only display the event information of type among this range. Moving Step: Every moving step for displaying the ev ent information. Unit is pixel. Moving Rate: The interval time between two mo ving steps. Unit is 100ms. 【Format】The content is as following table. Format for event information display,all the format information will display befor e the event information. Event Trig Time The time when event is triggered. Extended Time Format(D/H:M) Time format is...
Page 35
New Function 1. Find/Replace Find/Replace Click menu “Edit”->”Find/Replace” or click the icon ,then it will popup following dialogue box. Find Range Indicates the contents needed to find in EV5000, it can be separated into four kinds as following Description for Find Range Current Project Find all the HMI frames,mac ros,background databases. Find Range Background Database Find background database such as event information logon,alarm information logon,trend curve and so on.
Page 36
Frames and Macros Find all the frames and macros in current project. All FramesFind all the frames in current project. All HMI All MacrosFind all the macros in current project. Frames and Macros Find all the frames and macros in current HMI. All FramesFind all the frames in current HMI. Current Frame Find the current frame in current HMI. Current HMI Macros Find all the macros in current HMI. Find Description for Find Types Register Type Indicate the register type which need to...
Page 37
2. Windows Preview Click Windows Preview in Project Structure Window ,it will display the preview of the frames as following. 3. FTP Function EV5000 has opened FTP function,the users can copy the data files from SD card or U disk to PC,or from PC to SD card or U disk by LAN. FTP function is only suitable for the HMI which support Ethernet port and USB HOST or SD card. FTP Function Setting. 1.Enter the HMI option in HMI attribute,then tick Open FTP Passwords and set password. 1...
Page 38
2.Save project and compile,then download to HMI. 3 . Use Ethernet cable to connect to LAN,then open explorer.Input the IP: ftp://192.168.100.241 and press Enter,then it will popup following window.Input the user name and password,then it will login the FTP server. User name is root .
Page 40
4. Run the project in U disk or SD card directly When users make lots of pictures in the project, then it will cause that the project is too large to download into HMI. At this time, user s can download the project to U disk or SD card. 1. This function is only suitable for t he HMI which support USB HOST or SD card. 2. The project can’t run if it is copied to U disk directly. 3. The U disk can’t be pulled up when the project is running. Tick Download to USB1 or USB2 or SD when...