    Have a look at the manual Anaheim HMIPLC Release note for Version 16 all20110601 Users Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 523 Anaheim manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							
     
    Specific attribute is as following table. 
    Not tick   The X,Y positions of dynamic graph are constant.   The Upper-left 
    Corner of Variable 
    Tick The X,Y positions of dynamic  graph are variable.X position = 
    the first address,Y position = second address 
    Not tick   The width/height of  dynamic graph are constant.   The Widthe/Height 
    of Variable 
    Tick  The width/height of dynamic gr aph are variable. Width = first 
    address, Height = second address. 
     
    For example: 
    1.Dynamic circle graph,set the  address of the upper-left corner  of variable as LW0,and set 
    the address of the width/height  of variable as LW2.Set 
    LW0=0,LW1=0,LW2=100,LW4=100. 
    The effect is as following figure:  
    						
    							
     
    2. Dynamic circle graph,set the address of the upper-left corner of variable as LW0,and 
    set the address of the width/height of variable as LW2.Set 
    LW0=50,LW1=80,LW2=200,LW4=100. 
    The effect is as following figure:  
    						
    							
     
    9. Event Bar 
    Event Bar component is used to rolling display th e current trigger event information. 
    1.Event Info Scrollbar Component Attribute  
    						
    							
     
    Display Type Range: Only display the event information of type among this range. 
    Moving Step: Every moving step for displaying the ev ent information. Unit is pixel. 
    Moving Rate: The interval time between two mo ving steps.    Unit is 100ms. 
    【Format】The content is as following table. 
    Format for event information display,all the format information will display befor e the event information. 
    Event Trig Time The time when event is triggered. 
    Extended Time Format(D/H:M) Time format is Day/Hour:Minute 
    Short Time Format(H:M) Time format is Hour:Minute 
    Standard Time Format(H:M:S) Time  format is Hour:Minute:Second 
    Precise Time Format(H:M:S:MS) Time  format is Hour:Mi nute:Second:Millisecond 
    Extended Date Format(Y/M/D) Date format is Year/Month/Day 
    Event Trig Date(M/D) Date format is Month/Day 
    Time Ascending Order Display Tick indicates the latest event  information display at the back. 
    Not tick indicates the latest event  information display in the front. 
     
     
    1.Event Bar doesn’t support the such formats as “Sequence 
    No.”,”Acknowledge Time”,”Return to  Normal Time” and “Only show the 
    Event which doesn’t recover” option.   
    2.Once the triggered event recover,t he event bar won’t display this event. 
      
    						
    							
    New Function 
    1. Find/Replace   
    Find/Replace 
    Click menu “Edit”->”Find/Replace” or click the icon ,then it will popup following 
    dialogue box. 
     
     
    Find Range  
    Indicates the contents needed to find in EV5000, it can be separated into four kinds as 
    following 
    Description for Find Range 
    Current 
    Project Find all the HMI frames,mac ros,background databases. Find 
    Range 
    Background 
    Database Find background database such as event information 
    logon,alarm information logon,trend curve and so on.  
    						
    							
    Frames 
    and 
    Macros Find all the frames and macros in current 
    project. 
    All FramesFind all the frames in current project. 
    All HMI 
    All MacrosFind all the macros in current project. 
    Frames 
    and 
    Macros Find all the frames and macros in current HMI. 
    All FramesFind all the frames in current HMI. 
    Current 
    Frame Find the current frame in current HMI. 
    Current 
    HMI 
    Macros Find all the macros in current HMI. 
     
    Find  
    Description for Find Types   
    Register 
    Type Indicate the register type which need to find such as bit 
    address or word address. Register 
    Addr.Type Indicate the address type and address in the controller which 
    we need to find.Tick “Range” indicate to find in the setting 
    address range. 
    Not tick “Match Case” and “Full Match”  indicates that don’t match the letters 
    case and full-text consistent. 
    Match Case Indicate the text which  need to find must match the letters 
    case. 
    Text 
    Full Match Indicate the text which  need to find must match full-text 
    consistent. 
     
    Replace  
    Set address type and address to replace the address type and address which conform 
    to the find condition.   
    When user tick “Range” in Find,then the “A utomigration by Cor. Address” will 
    activate.If don’t tick “Automigration by Cor.  Address”,then the address for replace is the 
    same.If tick “Automigration by  Cor. Address”,then the address  for replace is consider the 
    address in “Replace” as initial address and then automatic migration. 
    After setting the parameters above,click the “Find” button, then it will search the 
    address in the range which conform to the find c ondition.If the address is found,then it will 
    display its No.,Location,Name and Data in t he white box in the bottom.If we double click 
    it,then the frame will jump to the location  of the component by automatic and popup its 
    attribute window. 
    Click “Replace” or “Replace All”,then it  will replace all the address type and address.  
    						
    							
    2. Windows Preview 
    Click Windows Preview  in Project Structure Window ,it will display the preview of 
    the frames as following. 
     
    3. FTP Function 
    EV5000 has opened FTP function,the  users can copy the data files from SD card or U 
    disk to PC,or from PC to SD  card or U disk by LAN.   
     
    FTP function is only suitable for the HMI which support Ethernet port and 
    USB HOST or SD card.   
     
    FTP Function Setting. 
    1.Enter the HMI option in HMI attribute,then tick  Open FTP Passwords and set 
    password. 
     1 .Default password :888888 
    2.Password only support number,don’t support characters. 
       If the password is empty,it w ill mention “FTP password can not be 
    empty”. 
    2 .Set IP address of HMI,the top three secti on of the IP address must be the same as 
    LAN,the last section must be different from PC. 
    3 .The subnet mark must be the same as LAN.Generally users needn’t modify this 
    parameters.  
    For example,we visit the datas in SD card through LAN.   
    1 .Set the IP address of HMI as 192. 168.100.241,Subnet Mark and Gateway as 
    default.Password is 123456.  
    						
    							
     
    2.Save project and compile,then download to HMI. 
    3 . Use Ethernet cable to connect to  LAN,then open explorer.Input the 
    IP:
    ftp://192.168.100.241 and press Enter,then it will popup following window.Input 
    the user name and password,then it  will login the FTP server.   
     User name is root .  
    						
    							
     
     
     
    4.Open the folder “sd”,then we can visit the SD card in HMI.  
    						
    							
     
    4. Run the project in U disk or SD card directly 
    When users make lots of pictures in the project, then it will cause that the project is too 
    large to download into HMI. At this time, user s can download the project    to U disk or SD 
    card.  
     
    1. This function is only suitable for t he HMI which support USB HOST or SD 
    card. 
    2. The project can’t run if it  is copied to U disk directly. 
    3. The U disk can’t be pulled  up when the project is running. 
    Tick Download to USB1 or USB2 or SD  when downloading the project as following 
    figure: 
    						