    Have a look at the manual Anaheim HMIPLC Release note for Version 16 all20110601 Users Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 523 Anaheim manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							
    Clear FRW Data: Clear the data that saved in FRW register 
    Download to USB1 : Down the project to USB1 , and run it in USB1 
    Download to USB2: Down the project to USB2 , and run it in USB2 
    Download to SD: Down the project to SD ca rd, and run it in SD card. 
    45 EV5000 V1.6 can run in the vista and win7 operation system 
    When use the vista operation, please note that: 
    a. Support the 64 bit operation system only 
    b. Don’t install Ev5000 in the C disk , and login the system with adm inistrator identity 
    c.Right click the Ev5000.exe choose the  Compatible with XP 
     
    46 Compatibility of EV5000   
       Ev5000 is upward compatible, but not  backward compatible. The new version can 
    open the old version project, but not the reve rse. When the new version software open the 
    project create by old version software, EV5000 will backup the project, then open it in high 
    version software. 
     
        EV5000 prompt backup the  old project or not ,click Yes to backup the project, and this 
    backup project will be found in the file named  copy in the project file. If the user wants to 
    open the project by old version software  , the old project can be found in the copy file .  
    						
    							
     
    If click No, cancel the operation. 
    Explains for the files in the project folder: 
    temp : Backup project that compiled the last time 
    ProjBK:  If click No,  system bucks up a old version in the  ProjBK folder  
    47 Full screen logo is supported 
    The HMI that support full screen logo are 4424T and 4424TE 
    48 How to judge if the USB disk and SD card are read by HMI . 
    Note   This function is only suitable for the HMI that support USB host or SD card 
    Set the dial code switch 1 and 2 to  ON position, as shown in the picture: 
     
    Reset the HMI, HMI display the picture as followings(Take 520T for example)  
    						
    							
     
    Click  or  
    1 If the USB disk or SD card are not read by HMI, it display the screen as follows: 
     
    2 If the USB disk or SD card are read by HMI, it display the screen as follows: 
     
    There will be a SD card or USB disk sign displaye d, that is to say the USB disk or SD card 
    are read by HMI. 
    49 Only Show Fast Selection Button  
    						
    							
    In Task Bar  of HMI Attribute  , click the Only Show Fast Selection Button.  So the HMI 
    only show the fast selection button. 
     
    The offline simulation effect: 
      
    						
    							
    50 The Chinese font box height is adjustable 
    When we use phoneticize input methods, the Chinese font box height is adjustable, it is in 
    the  Chinese Font Box Height  of HMI Extended Attribute  in HMI Attribute, and it ranges 
    from 24 pixels to 99 pixels. 
     
    The offline simulation effect: 
    If the  HMI Extended Attribute  is 24: 
     
    If the  HMI Extended Attribute  is 34: 
     
    51 The notification function of Controllin g component can notice word register 
    In Bit State Setting ,Bit State Switch , Number Input etc component add the function of 
    noticing word register. 
    Trigger Written Notice   Write the  Written Value  into the specified  
    						
    							
    word register address before the signal input 
    the controller   
    Register(Word) After Written 
    Notice Write the Written Value  into the specified 
    word register address after the signal input 
    the controller 
     
    For example: Number Input component LW0,  notice the LW10 , the Written Value is 100 
    after LW0 is written. 
    The settings of  Notification in Control Setting  of Number Input component :  
    						
    							
     
    The offline simulation effect is as follows: 
    Before input value into the LW0: 
     
    After input value into the LW0: 
     
     
    Add new PLC drivers 
    1 Siemens 1200 network driver protocol    
    						
    							
    2 Siemens 300 network driver protocol 
    3 Yokogawa FA-M3 serial port driver 
    4 Yokogawa FA-M3 Ethernet port driver 
    5 Millenium 3 
    6 Parker SLVD 
    7 RKC driver 
    8 Tsinghua Moto field bus driver 
    9 Modrol driver 
    10  Inovance H2u driver 
    Add new printer driver 
    Add a new printer(MeiYu), the type is MY-POS80K 
       
    						