Home > Anaheim > HMI/PLC > Anaheim HMIPLC Release note for Version 16 all20110601 Users Guide

Anaheim HMIPLC Release note for Version 16 all20110601 Users Guide

    Download as PDF Print this page Share this page

    Have a look at the manual Anaheim HMIPLC Release note for Version 16 all20110601 Users Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 523 Anaheim manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							
     
    Password: place a Number Input component, t he Address is Lw9502, Word Length 
    is 2 ,Data Type is Password. 
     
    Confirm password:  place a Number Input component, the Address is Lw9510, Word 
    Length is 2 ,Data Type is Password.  
    						
    							
     
    Logoff Time: place a Number Input component, the Address is Lw9508, Word 
    Length is 2 ,Data Type is Unsigned Int : 
     
    Set the user permission : Place four Bit State Switch , their Address is LW9506.0, 
    LW9506.1, LW9506.2, LW9506.3.  Switch Type is Toggle.  
    						
    							
     
    Add: Place a Bit State Switch component, t he Address is LB9167., Switch Type is 
    On,. This component is user to add user permission. 
     
     
    The simulation effect is as the following picture:  
    						
    							
     
    Click the Add user. , it will pop up a dialog box like that: 
     
        Input user name that need to add, set the password and confirm the password, 
    then set the permission of the user. After the  above setting , click Add, so the user is 
    added.  
    						
    							
     
    2 Delete the user permission: 
    The Delete window contains  User, Password, Confirm password, Delete.  
     
    Settings of User, Password, Confirm password     in Delete window are the same as 
    the User setting window. 
    Delete:  Place a Bit State Switch component, t he Address is LB9168., Switch Type is 
    On,. This component is used to delete user permission.   
    Note Delete user permission is only effective to the users that added 
    via HMI. The users set in the conf iguration project can not be delete
    d  
    The following picture is the ef fect of offline simulation: 
    Click the Delete, pop up a  dialog box named Delete user  
    						
    							
     
    Input the user name ,password    and confirm the password, then click the Delete,  
    then the user is deleted. 
     
     
    12 Clear/export the compiling message  
    						
    							
    In the Message Window, you can clear or export the compiling message. Click the 
    right left mouse button in the Mess age window, it will pop up two options: 
     
    Clear Messages: Clear up all the compiling messages in the Message window. 
    Export Messages:  Export the compiling message to  the folder where the current 
    project loaded. The file name is log.txt   
    13 Event Information can trigger the Buzzer. 
    In the Event Information, add a new function named Use Buzzer and Buzzing Time 
    can be set. The unit is seconds.. 
     
     
    Improvement of components   
    1 Meter 
      Meter add the function of Using Scale to di splay, the upper and lower limit in Alarm 
    can be labeled by color block, and Variable  Lower / Upper Limit in Meter Component 
    Extended Attribute 
    (1) Meter  
    						
    							
     
    Basic Attribute
    ◆  
    Dial Style: Choose the dial style of Meter 
     
    Hand Style:  Choose the hand style of Meter 
     
    Hand Color:  Chose the hand color of Meter 
    Point Length:  Change the point length of Meter. T he utmost length is the radius of 
    the Meter’s actual cycle  
    						
    							
    ◆Scale attribute 
    Use Scale : Select to display the scale of Meter 
    Scale Color : Chose the scale color of Meter 
    The Number of Main Scale  : Change the number of main scale. The range is from 0 
    to 50 
    The Length of Main Scale  :Change the length of main scale. The utmost length is 
    the radius of the Meter’s actual cycle 
    The Number of Minor Scale : Change the number if minor scale 
    The Length of Minor Scale; Change the length of minor scale. The utmost length is 
    the radius of the Meter’s actual cycle 
    Show Scale Frame:  Select to show scale frame 
     
    Scale tag 
    Use Scale Tag: Select to display the scale tag  
    Tag Font: Click the Tag Font to se t the font of Scale Tag 
     
    Integer: Integer of scale tag.(Can not be set ,  but it can be adjusted by the Maximum 
    of  the Meter automatically) 
    Decimal : Change the decimal of scale  tag. (Ranges from 0 to 8) 
    Attribute of Dial Axis
    ◆  
    Use Dial Axis: Select to change the size and color of the Dial Axis. 
    Axis Width: Change the size of the dial axis. The utmost width is the radius of the  
    						
    							
    Meter’s actual cycle 
    Axis Color: Change the color of dial axis. 
    2 Meter Component Extended Attribute 
     
    Maximum and Minimum:
    ◆  
    Minimum: Set the scale’s minimum of Meter 
    Maximum:  Set the scale’s Maximum of Meter 
    ◆Variable Min/Max  
    Variable Min/Max: If checked ,means that the scale’s minimum and maximum will 
    use variable in   
    Addr.Type : Address type of the variable register, it is a word register 
    Address: The first address of variable register 
    Word Length : Word length of variable register, the default is 2.  Suppose the variable 
    register Address of Minimum and Maximum used  is Lw1, That is to say LW1 is the 
    variable that  Minimum used, LW2 is the variable that  Maximum used. 
    ◆Alarm 
    Alarm:  If checked, it means the Meter uses  color block to label Upper/Lower Limit 
    alarm. 
    Upper Limit Color: Set block color of upper limit area of the Meter. 
    Lowe Limit Color:  Set block color of lower limit area of the Meter 
    Normal Color: Set block color of normal lower limit area of the Meter. 
    Fan Thickness:  Set the thickness of ring like color bl ock, the utmost is the radius of 
    the Meter’s actual cycle and it must be le ss or equal to the Fan External Radius. 
    Fan External Radius: Set radius of the ring like color  block. The utmost is the radius 
    of the Meter’s actual cycle and it must  be bigger or equal to the Fan Thickness.  
    						
    All Anaheim manuals Comments (0)