Page 61

 
Besides the settings in User Permission Setting of the HMI Attribute, the following 
special registers are also used to build a project of user permission. 
Address Function Explanations 
LW9486~LW9501 Input the user’s name 32 characters is the utmost 
LW9502~LW9503 Input the corresponding  password of the user Double words 
LW9504~LW9505 Display the current user’s permission Double word ,read-only component ,
display the corresponding permission
LB9165 Confirmation of user  login Execute login...

Page 62

 
 
Address Function Explanations 
LW9486~LW9501 Input the user’s name 32 characters is the utmost 
LW9502~LW9503 Input the corresponding 
password of the user Double words 
LW9506~LW9507 Distribute the user permi
ssion Double words ,readable and writable ,
distribution of 32 permission ,LW 950
6~9507 correspond the 32 permissio
ns numbered from 0 to 31, LW. B  c o r
respond each bit in  LW 9506~9507 ,
for example :LW.B 9506.0 means the
 permission numbered 0 。LW.B 9506.
A means the permission numbered...

Page 63

 
User 0 
 
 
User 1  

Page 64

 
User 2 
Set the 
◆ Permission Control  of components: 
    In Control Setting of component attribute, select the  Conditional Enabling, and 
select the  Permission Control  as the following figure: 
  

Page 65

The components that set Permission Control can only be operated by the users 
who have this permission. 
◆  Login page of user permission 
Place a Bit State Setting component, suppose  the Address is LB 0,Type is On. This 
component is used to pop up the di rect window of User permission. 
  

Page 66

 
Add a new configuration window to be the User permission window: 
Place a Text Input component to input the user’s name, the Address is LW9486, Word 
Length is 10. 
 
Then place a Number Input component to input the password, the Address is Lw9502,   

Page 67

Word Length is 2, Data Type is Password. 
 
Then place a Bit State Setting component to login the permission, the Address is 
LB9165, Type is On, T ag content is Login 
 
At last, place a Bit State Setting component  to logoff the permission, the Address is 
LB9166, Type is On, Tag Content is Logoff.  

Page 68

 
The offline simulation effect is as following figure: 
Input Engineer  in the User and  222222 in the Permission password, then click Login. 
  

Page 69

 
 
Add and delete user permission
◆  
Place a User Info Display component in Us er setting window, this component is used 
to display the current user’s information, t he Table Display Attributes can be set according 
to the need of User Setting window.  

Page 70

Add user 
 
 
The window of Add user contains User, Password, Confirm password, Logoff  
Time, Set the user permission. 
User:  place a Text Input component to input the user’s name, the Address is 
LW9486,Word Length is 10, the utmo st of    Word Length is 16.  