Page 61
Besides the settings in User Permission Setting of the HMI Attribute, the following special registers are also used to build a project of user permission. Address Function Explanations LW9486~LW9501 Input the user’s name 32 characters is the utmost LW9502~LW9503 Input the corresponding password of the user Double words LW9504~LW9505 Display the current user’s permission Double word ,read-only component , display the corresponding permission LB9165 Confirmation of user login Execute login...
Page 62
Address Function Explanations LW9486~LW9501 Input the user’s name 32 characters is the utmost LW9502~LW9503 Input the corresponding password of the user Double words LW9506~LW9507 Distribute the user permi ssion Double words ,readable and writable , distribution of 32 permission ,LW 950 6~9507 correspond the 32 permissio ns numbered from 0 to 31, LW. B c o r respond each bit in LW 9506~9507 , for example :LW.B 9506.0 means the permission numbered 0 。LW.B 9506. A means the permission numbered...
Page 64
User 2 Set the ◆ Permission Control of components: In Control Setting of component attribute, select the Conditional Enabling, and select the Permission Control as the following figure:
Page 65
The components that set Permission Control can only be operated by the users who have this permission. ◆ Login page of user permission Place a Bit State Setting component, suppose the Address is LB 0,Type is On. This component is used to pop up the di rect window of User permission.
Page 66
Add a new configuration window to be the User permission window: Place a Text Input component to input the user’s name, the Address is LW9486, Word Length is 10. Then place a Number Input component to input the password, the Address is Lw9502,
Page 67
Word Length is 2, Data Type is Password. Then place a Bit State Setting component to login the permission, the Address is LB9165, Type is On, T ag content is Login At last, place a Bit State Setting component to logoff the permission, the Address is LB9166, Type is On, Tag Content is Logoff.
Page 68
The offline simulation effect is as following figure: Input Engineer in the User and 222222 in the Permission password, then click Login.
Page 69
Add and delete user permission ◆ Place a User Info Display component in Us er setting window, this component is used to display the current user’s information, t he Table Display Attributes can be set according to the need of User Setting window.
Page 70
Add user The window of Add user contains User, Password, Confirm password, Logoff Time, Set the user permission. User: place a Text Input component to input the user’s name, the Address is LW9486,Word Length is 10, the utmo st of Word Length is 16.