If select the Unloop, the Multiple State Switch will  not loop when add/sub to the limit. 
If uncheck the Unloop, Multiple State Switch will add  or subtract repeatedly from the 
lower limit when it reach the upper limit 
2 Line Space of  List and Dropdown list  can be set 
 
7 For EV5000 V1.6, add a function of  Use Input Order in Number Input ,Text Input , 
Note Book component..   
If select the  Use Input Order  in Number Input ,Text Input , Note Book component, 
you can input values in t hem...

Page 92

Group: It is used to classify the components  that needs to input value continuously, 
component with same group number are in the  same group, the cursor will blinking among 
the components of same group  circularly ,the keyboard will not close even if you click 
ENTER ,it will close until you click the X button.   
Settings of Use Input Number 
In Number Input ,Text Input ,  Note Book component, select the  Use Input Number. 
  

Page 93

 
8 Variable Parameters in Multi-State Setting 
Add a option of Variable parameters in Multi-State Setting of Multiple State Setting 
component. If checked, that is to say the Up per and Lower can use variable parameters. 
Example : 
1 Setting Mode  is Set Constant  
Suppose the Address in Multiple State Setting component is LW0, Setting Mode is 
Set Contract, select the Variable Pa rameters, and its Address is LW10. 
 
If When Lw10=5, that is to say the constant is 5,click  Set, 5 in the LW10 will be...

Page 94

 
The setting Mode is Add 
    Suppose the address of Multiple State Setting is LW5,Setting Mode is Add Value, 
select the  Variable Parameters, the Address of Variable Parameters is LW15 , Word 
Length is the Default 2, that is to say, the  Addend is the value of LW15 ,the  Upper is 
LW16 . 
 
Then place two Number Input components, the Addresses are LW15,Lw16. and place 
a Number Display component, the Address is LW5: 
  

Page 95

If LW15 =10, Lw16=100, that is to say , the value of LW5 will add 10 every time you 
click  Set until it goes to the Upper 100. 
Offline simulation effect: 
 
9 Bar Picture 
Add a Offset type in  Bar Type 
The display effect of offset Bar Picture is  the offset between the actual value and 
deviation of the original data type. For exampl e, deviation of the original data is 50, and 
the actual value in the register is 60, so the  Bar Picture display the effect of 10. 
 
Comparison of effect between the...

Page 96

Add a Cycle type in Bar Type 
 
Comparison of effect between Rectangle and Circle of Bar shape 
Rectangle Circle 
  
3 Add Target value , Permissible Error and Color  
The function of Target value: set a permi ssible range value, and the set Color can be 
display in this range. 
Permissible Error: the value of Target Val ue change, for example the Target Value is 
60 , the Permissible Error is 10, so the r ange of Target Value is from 50 to 70. 
Example: 
Target Value is 60, Permission Error is 10,...

Page 97

 
If the Over Upper Limit Flashing checked, when the current value is over upper 
limit  , the Bar Picture glitter between  Alarm Upper color and Background color, if 
unchecked, it will not glitter. 
If the Over Lower Limit Flashing  checked, and  if the current value is over lower 
limit  , the Bar Picture glitter between  Alarm Lower color and Background color, if 
unchecked, it will not glitter. 
Add a Scale function 
The scale can be displayed  conveniently if choose the Use Scale, so you need not...

Page 98

 
Uncheck Use Scale Check Use Scale 
  
  
10 Backstage components add function of Import an Export 
Backstage components: In Text Library, Address Tag, Alarm Information, Event 
Information, PLC control, add  the function of import and export csv file.    The users can 
edit the content via csv file. 
 
Note When you save the csv file , please notice that: 
1.Click  Save,chose  Ye s,as shown in the following picture : 
2.Click Close,windows suggest you save or not, choose  Ye s, as 
shown in the...

Page 99

11 Number of text state can be changed in Text Library. 
The to change Number of text state in Text Library., click a state and right click. as 
shown in the following picture. 
 
Note Only Language Setting in HMI Extended Attribute and Language Text 
Library can save the attribute of entire language     
12 Event Display component   
In Event Display, add two formats of  Time ascending Order Display and Only show 
the event which doesn’t recover.  

Page 100

 
Time ascending Order Display: if checked, the latest event is shown in the bottom, 
the number and time of a event increase successively from the top to bottom. As shown in 
the picture: 
 
If uncheck  Time ascending Order Display,  the default is Time descending Order 
Display, the latest event is  shown on the top, the number  and time of a event decrease 
successively from the top to botto m. As shown in the picture:  
Start reading Anaheim HMIPLC Release note for Version 16 all20110601 Users Guide